• Title/Summary/Keyword: Inter-connected

Search Result 235, Processing Time 0.034 seconds

Study on the Measuring of Power Quality for the Residental PV System (가정용태양광 발전설비의 전력품질 측정에 관한 연구)

  • Ahn, Jae-Min;Han, Woon-Ki;Jung, Jin-Soo;Kim, Sun-Gu;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2176_2177
    • /
    • 2009
  • This paper describe the power quality measuring result of the inter-connected residental PV system. The power quality measuring for inter-connected residental PV system are important to verify their performance and effect of power distribution system with inter-connected residental PV system. Also, these power quality measuring and analysis are essential to improve electrical safety. In order to evaluate influence of power distribution system with inter-connected residental PV system, we measure and analyze power quality index such as power, voltage, current, harmonic, THD, flicker index, power factor and frequency using DEWE5000.

  • PDF

The Effects of the Social Contribution Activities on Local Developmental Achievement with a focus on the Mediating effect of Inter-Firm Connected Activity (사회공헌활동이 기업 간 연계 활동의 매개효과를 중심으로 지역발전성과에 미치는 영향)

  • Ahn, Jae-Hyun;Hong, Seok-Jin;Kim, Sun-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.516-529
    • /
    • 2018
  • Due to the growing awareness and demand for corporate social responsibility, the corporate activities designed to make a social contribution are becoming increasingly diversified. Nonetheless, according to a periodic survey, the public has become dissatisfied with the social contribution activities of domestic corporations. The perceptions of the social contribution activities of domestic corporations and the public were found to be quite different. In this study, the Social Contribution Activities were classified into three factors, "Socio-Cultural Resource Activities", "Indirect Social Resource activities" and "Economic Resource Activities", and the effect of each factor on the inter-firm connected activities and achievements of local development were analyzed. Firstly, the "Socio-Cultural Resource Activities" and "Indirect Social Resource Activities" were shown to have a positive effect on the Inter-firm connected activities in the community. Secondly, it was found that the more active the Inter-firm connected activities were in the community, the bigger their positive effect was on the achievements of local development. Thirdly, the "Economic Resource Activities" were shown to have a positive effect on the achievement of local development. Fourthly, "Socio-Cultural Resource Activities" and "Indirect Social Resource Activities" were shown to have a positive effect on the Inter-firm connected activities and an indirect positive effect on the achievement of local development. Based on this research, we quantitatively determine the relationship between the corporate social contribution activities and performance.

Indentation Damage of Porous Alumina Ceramice

  • Ha, Jang-Hoon;Lee, Chul-Seung;Kim, Jong-Ho;Kim, Do-Kyung
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.1
    • /
    • pp.19-23
    • /
    • 2004
  • The Hertzian indentation contact damage behavior of porous alumina with controlled pore shape was investigated by experiments. Porous alumina ceramics containing well-defined pore shape, size and distribution were prepared by incorporation of fugitive spherical starch. Porous alumina with isolated pore structure was prepared with porosity range up to 30%. The indentation stress-strain curves of porous alumina were constructed. Elastic modulus and yield stress can be obtained from the stress-strain relationship. Impulse excitation method for the measurement of elastic modulus was also conducted as well as Hertzian indentation and was confirmed as a useful tool to evaluate the elasticity of highly porous ceramics. Elastic modulus of the inter-connected pore structure is more sensitive to porosity than that of the isolated pore structure. When the specimen had isolated pore structure, higher yield point was obtained than it had inter-connected pore structure. This study proposed that the elastic modiulus of porous ceramics is strongly related to not only porosity, but also the structure of pore.

Realization of Internet Supercomputing Technology (인터넷 수퍼컴퓨팅 기술의 구현)

  • 김승조
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.1-8
    • /
    • 2000
  • In this work, Internet Supercomputing methodology is introduced and the concept is materialized for large-scale finite element analysis. The primary resources of Internet Supercomputing are numerous idling PCs connected by Internet with no regards to their locations. Therefore, it becomes one of the most affordable ways to achieve supercomputing power unlimitedly if the appropriate parallel algorithm and the operating program are developed for this slow network environment. Under the above concept, virtual supercomputing system InterSup I is constructed and tested. To establish the InterSup I system, 64 CPU nodes, which are located in several places and connected by Internet, are conscripted, and parallel finite element software is developed for linear static analysis of structures based on the parallel multi-frontal algorithm. By the established InterSup I system, analysis of finite element structural model having around five million DOFs are solved to check the affordability and effectiveness of Internet Supercomputing.

  • PDF

Control of Parallel Connected Three-Phase PWM Converters without Inter-Module Reactors

  • Jassim, Bassim M.H.;Zahawi, Bashar;Atkinson, David J.
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.116-122
    • /
    • 2015
  • This paper presents a new current sharing control strategy for parallel-connected, synchronised three-phase DC-AC converters employing space vector pulse width modulation (SVPWM) without current sharing reactors. Unlike conventional control methods, the proposed method breaks the paths of the circulating current by dividing the switching cycle evenly between parallel connected equally rated converters. Accordingly, any inter-module reactors or circulating current control will be redundant, leading to reductions in system costs, size, and control algorithm complexity. Each converter in the new scheme employs a synchronous dq current regulator that uses only local information to attain a desired converter current. A stability analysis of the current controller is included together with a simulation of the converter and load current waveforms. Experimental results from a 2.5kVA test rig are included to verify the proposed control method.

Protection for a Wind Turbine Generator in a Large Wind Farm

  • Zheng, Tai-Ying;Kim, Yeon-Hee;Kang, Yong-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.4
    • /
    • pp.466-473
    • /
    • 2011
  • This paper proposes a protection algorithm for a wind turbine generator (WTG) in a large wind farm. To minimize the outage section, a protection relay for a WTG should operate instantaneously for an internal fault or a connected feeder fault, whereas the relay should not operate for an internal fault of another WTG connected to the same feeder or an adjacent feeder fault. In addition, the relay should operate with a delay for an inter-tie fault or a grid fault. An internal fault of another WTG connected to the same feeder or an adjacent feeder fault, where the relay should not operate, is determined based on the magnitude of the positive sequence current. To differentiate an internal fault or a connected feeder fault from an inter-tie fault or a grid fault, the phase angle of the negative sequence current is used to distinguish a fault type. The magnitude of the positive sequence current is then used to decide either instantaneous operation or delayed operation. The performance of the proposed algorithm is verified under various fault conditions with EMTP-RV generated data. The results indicate that the algorithm can successfully distinguish instantaneous operation, delayed operation, or non-operation depending on fault positions and types.

A case Study for Protection Relay System of small Cogeneration intertie (단순병렬 자가발전 설비 보호방식 검토 사례)

  • Lee, S.J.;Kim, K.S.;Yoon, K.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.234-236
    • /
    • 2002
  • The Co-Gen System which maximize energy efficiency was installed at the industrial plants at the initial stage. However Small Scale Co-Gen System was expanded even to the general end-users such as housing and building owing to ESCO business recently. For this SSC, inter-connected operation to the utility is desirable due to voltage and frequency fluctuation following to unbalance between power output and load. Then voltage unbalance with utility system, frequency, increase of short circuit capacity, reclosing, and ALTS etc. should be fully considered for the inter-connected operation. Voltage variation, protection coordination, Co-Generators single running, and short circuit capacity should also be solved. To research the method and solve the problems through the field test and application, we study individual customers Co-Gen System as a case study.

  • PDF

Smart passive control of buildings with higher redundancy and robustness using base-isolation and inter-connection

  • Murase, Mitsuru;Tsuji, Masaaki;Takewaki, Izuru
    • Earthquakes and Structures
    • /
    • v.4 no.6
    • /
    • pp.649-670
    • /
    • 2013
  • It is known that a base-isolated building exhibits a large response to a long-duration, long-period wave and an inter-connected system without base-isolation shows a large response to a pulse-type wave. To compensate for each deficiency, a new hybrid passive control system is investigated in which a base-isolated building is connected to another building (free wall) with oil dampers. It is demonstrated that the present hybrid passive control system is effective both for pulse-type ground motions and long-duration and long-period ground motions and has high redundancy and robustness for a broad range of disturbances.

Economic Analysis on Inter-Connected System of Port Transport and In-land Transportation -A Container Cargo Transport Oriented- (부산항 항만 운송과 육상 교통 연계시스템에 관한 경제성 분석 -컨테이너 화물 운송을 중심으로-)

  • Kwak, Kyu-Seok;Kim, Tae-Gon;Choi, Jae-Soo;Ahn, Ki-Myung
    • Journal of Korean Port Research
    • /
    • v.5 no.1
    • /
    • pp.29-54
    • /
    • 1991
  • In this study, to identify the ineffectiveness of inter-connected system of cargo volume between the Pusan Port and inland areas and also to make more rational suggestions, the following conclusions were drawn by analyzing Container Cargo Traffic from BCTOC to Off-Dock CY: 1. There existed about 30% to 50% reduction in the container transport times when the container transport vehicles were operated during the off-peak period to alleviate the traffic congestion due to mixed traffic. 2. There appeared to be more economic when Off-Dock DY's scattered around the City of Pusan were unified in one ODCY Unit at YangSan, and the Exclusive Overpass Freeway System for the container transport vehicles were constructed and operated on the existing Urban Freeway from BCTOC ti this ODCY Unit (Expected to make about 230 billions Won in net present value by NPV method).

  • PDF

Development of Inter-Working Function Unit for the Advanced TDX Remote Subscriber Systems (TDX 고도화 시스팀 원격가입자 정합장치 개발)

  • 황우근;우창희;류영일
    • Proceedings of the IEEK Conference
    • /
    • 2000.11a
    • /
    • pp.299-302
    • /
    • 2000
  • In this paper, a Inter-Working Function Unit(IWF) has been developed and designed in order to change to advanced subscriber system the Remote Subscriber System(RSS) that is operating with simple services(PSTN Function only). Regarding the cost and the effectiveness, RSS should be connected to Access Subscriber System with PCM cables directly. As this method being used, in the period of Retrofit, the connecting job covering RSS will be handled easily and safely.

  • PDF