• 제목/요약/키워드: Inter-Rater reliability

검색결과 197건 처리시간 0.021초

Inter- and Intra- Rater Reliability of Navicular Drop Tests Position

  • Kim, So-yeon;Yoo, Jung-eun;Woo, Da-hyun;Jung, Bo-young;Choi, Bo-ram
    • 대한물리치료과학회지
    • /
    • 제26권1호
    • /
    • pp.9-14
    • /
    • 2019
  • Background: Pes planus, or flat foot, causes lower limb malalignment and foot pain during walking or exercise. Therefore, a highly reliable evaluation method to accurately diagnose flat feet is necessary. This study investigated the intra-and inter-rater reliability of the navicular drop test in different postures. Design: Cross sectional study. Methods: Forty healthy volunteers performed the navicular drop test in three different combinations of non-weight-bearing and weight-bearing postures (standing/standing, sitting/sitting, and sitting/standing). Two examiners alternately performed the measurements five times in each subject, and in each posture. Significant differences in measurements were obtained among the three postures, with the highest navicular drop being observed in the sitting/standing posture. Results: Inter-rater reliability was high in the sitting/standing and sitting/sitting postures. Intra-rater reliability was high in all three postures. In the sitting/sitting and sitting/standing postures, large navicular drop values and high inter- and intra-rater reliability were observed. Conclusion: Therefore, the sitting/standing and sitting/sitting postures are recommended for use in navicular drop tests to diagnose flat feet.

청년과 노인 연령군에 따른 척주세움근에 대한 마이오톤의 측정자 간, 측정자 내 신뢰도 (Inter-and Intra-rater Reliabilities of Myotonometric Measurement of the Erector Spinae Muscles in the Young and Old Age Groups)

  • 한효경;최예주;정성호;이나경
    • 대한통합의학회지
    • /
    • 제9권1호
    • /
    • pp.193-202
    • /
    • 2021
  • Purpose : The purpose of this study is to examine inter-and intra-rater reliabilities of myotonometric measurements of tone, elasticity and stiffness for the erector spinae muscles of the young and the elderly populations. Methods : A total of 102 (69 young adults from K university and 33 older adults from the D community center in Daejeon) were enrolled in this study. The two different raters measured each side of the erector spinae muscles at prone position. After each rater performed first measurement for a subject, 30 minutes of rest was given. The same rater then repeated the second myometric measurement on the subject. The collected data on the tone, elasticity, and stiffness of the erector spinae were analyzed using intraclass correlation coefficient (ICC) to determine inter- and intra- rater reliabilities. Results : The inter-and intra-rater reliabilities of the myotonometric measurement of the erector spinae for the total subjects were excellent (ICC > 0.9, p < 0.001). Within each of the elderly group and the young group, inter- and intra-rater reliabilities were also excellent (ICC > 0.8~0.9 / p < 0.001, ICC > 0.75~0.9 / p < 0.001, each). Conclusion : The measurement of muscle tone, elasticity, and stiffness for the erector spinae muscles using the myotonometer had excellent reliability. It was confirmed that a highly reliable myometric measurement on the erector spinae can be obtained regardless of whether it is from young or elderly people. This suggests that the myotonometer can be a useful tool to measure muscular properties of the erector spinae of the young and old as an evaluative instrument.

의료인을 위한 구강점막욕창 시각적 감별도구의 신뢰도 (Reliability of the Visual Discrimination Scale on Oral Mucosa Pressure Ulcer for Healthcare Providers)

  • 엄주연;김명수
    • 한국융합학회논문지
    • /
    • 제11권11호
    • /
    • pp.443-450
    • /
    • 2020
  • 본 연구는 구강점막욕창의 시각적 감별도구에 대한 신뢰성을 평가하기 위한 연구이다. 연구의 절차는 개발단계와 평가단계로, 개발단계에서는 자료수집, 자문단의 타당도와 신뢰도 평가, 최종도구개발이 수행되었으며, 평가단계에서 대상자들에게 9장의 사진도구를 평가하게 하였다. 세 군에서 측정자 간 신뢰도를 구한 결과, 상처 전문간호사군에서는 Krippendorff's alpha 가 .75이었고, 중환자 전문간호사군에서는 .70이었다. 치과의사군에서의 Cohen's weighted kappa값은 .78 로 나타났다. 측정자 내 신뢰도를 살펴본 결과, 중환자실 일반간호사군들의 intra-rater reliability는 .73으로 나타났다. 신뢰도가 입증된 9장의 사진은 실제 중환자실과 같은 구강점막욕창 위험을 가진 환자를 돌보는 임상환경에서 교육용으로 활용될 수 있을 것으로 보인다.

Reliability and Validity of Measurement Using Smart Phone-Based Goniometer on Pelvic Tilting Angle in Standing and Sitting Position

  • Ha, Sung-Min;Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • 제31권1호
    • /
    • pp.35-39
    • /
    • 2019
  • Purpose: The purpose of this study was to assess the intra-rater and inter-rater reliability and validity of pelvic tilting angle measurements using a smart phone-based inclinometer (Clino) compared to a palpation meter (PALM) in the standing and sitting position. This study used an interchangeable method with Clino to measure the pelvic tilting angle in the standing and sitting positions. Methods: Twenty healthy subjects were recruited. Measurements of the pelvic tilting angle in the standing and sitting positions were obtained by two examiners using the Clino and PALM. A resting session was conducted 10 minutes later to assess the intra and inter rater reliability. To assess validity of the measurement using Clino, a PALM was used as the gold standard. The intra-class correlation coefficient (ICC) was used to determine the intra and inter rater reliability of Clino and a PALM. To assess the validity, the Pearson correlation coefficients were used for two measurement techniques to measure the pelvic tilting angle in the standing and sitting positions. The statistical significance was set to ${\alpha}=0.05$. Results: Measurements of the pelvic tilt had high inter-rater reliability in the standing (ICC=0.82) and sitting (ICC=0.88) positions using Clino and intra-rater reliability in the standing (ICC=0.87) and sitting (ICC=0.91) positions using Clino. Measurements of the pelvic tilt had high validity by a comparison of PALM and Clino in the standing (r=0.83) and sitting (r=0.89) positions (p<0.05). Conclusion: The use of Clino can be recommended as a tool to replace the PALM and measure the pelvic tilt angle in the standing and sitting positions while maintaining the clinical reliability and validity.

뇌졸중 환자 평가를 위한 Stroke Rehabilitation Assessment of Movement의 측정자간 신뢰도 (Inter-Rater Reliability of Stroke Rehabilitation Assessment of Movement for Patients With Stroke)

  • 윤성준;원종혁;이충휘
    • 한국전문물리치료학회지
    • /
    • 제17권3호
    • /
    • pp.48-58
    • /
    • 2010
  • The aim of this study was performed to determine the inter-rater reliability of the Stroke Rehabilitation Assessment of Movement (STREAM) translated in Korean. This was a new clinical measurement tool for evaluating the recovery of voluntary movement and basic mobility following stroke. A direct-observation reliability study was conducted on 20 patients who had strokes and were in a rehabilitation setting. Subjects were assessed by two physical therapists. The reliability of the STREAM scores was demonstrated by weighted kappa statistics for inter-rater agreement on scores for individual items ranged from .83 to 1.0, intraclass correlation coefficients for total score was .99, and for subscale scores was ranged from .96 to .99. The internal consistency of the STREAM scores was demonstrated by Cronbach alphas of greater than .99 on the subscales and overall. These high levels of reliability support the use of the STREAM translated in Korean instrument for the measurement of motor recovery following stroke.

Intra-Rater and Inter-Rater Reliability of Various Forward Head Posture Measurements

  • Yoo, Won-Gyu;Kim, Min-Hee;Yi, Chung-Hwi
    • 한국전문물리치료학회지
    • /
    • 제12권4호
    • /
    • pp.41-47
    • /
    • 2005
  • The purpose of this study was to determine the intra-rater and inter-rater reliability of various forward head posture measurements. Ten healthy adults (age, $20.4{\pm}2.2$ yrs; height, $164.0{\pm}5.5$ cm; weight, $58.7{\pm}7.3$ kg) participated in the study. They were free of injury and neurologic deficits in the upper extremities and neck at the time of testing. The subjects were asked to perform head forward posture by under the guidance of physical therapists. Markers were placed on the C7 spinous process, mastoid process, tragus of the ear, outer canthus, and forehead. Measurement 1 for forward head posture assessment was measured as the angle between the horizontal line through C7 and the line connecting the C7 spinous process with the tragus of the ear. Measurement 2 was measured as the angle between the C7 spinous process, the mastoid process and the outer canthus. Measurement 3 was measured as two kinds of angles the HT (head tilt) angle is between the line from the midpoint of forehead to the tragus line and Y-axis at the tragus point. The NF (neck flexion) angle is between the line from the tragus to the C7 line and the Y-axis at the C7. Intra-rater, inter-rater reliability and coefficient of variation was assessed by comparing the measured values from three kinds of measurements of forward head posture. The intra-rater reliability was indicated by intraclass correlation coefficients [ICC(1,1)] and inter-rater reliability was shown by intraclass correlation coefficients [ICC(3,k)]. The results of study were as follows: ICC(1,1) values for intra-rater reliability of three measurements were in the 'excellent' category. ICC(3,k) values for inter-rater reliability of three measurements were also in the 'excellent' category. The coefficient of variation of method 2 had a lower value than method 1 and method 3. This data means that the measured value of method 2 was less scattered. Further research is needed to determine whether the validity of all measurements is revealed in the 'excellent' category.

  • PDF

엉덩정강근막띠의 길이 평가를 위한 세 가지 측정방법들의 신뢰도 비교 (Reliability of Three Methods for Measuring Length of Iliotibial Tract)

  • 김문환;윤성준;원종혁
    • 한국전문물리치료학회지
    • /
    • 제21권3호
    • /
    • pp.20-27
    • /
    • 2014
  • The purpose of this study was to compare the intra-rater and inter-rater reliability of three methods for measuring iliotibial tract length in 40 knees of 20 subjects. The measurements were performed by two examiners and one assistant. The length of the iliotibial tract was measured using three methods: the first used a modified Ober test with an inclinometer, the second used a modified Ober test with a marker, and the third used active adduction test with a marker in the supine position. Each examiner used the three methods in two sessions. For the first method, the inclinometer value was recorded manually. For the second and third methods, Image J analysis software was used to analyze the photographs taken. The intra-rater and inter-rater reliability of the measured value was assessed by means of intra-class correlation coefficients [ICC (3,1)] and the standard error of measurement. The intra-rater reliabilities of the three methods were excellent (ICC=.97, .95, and .94, respectively), and the inter-rater reliabilities of the first and second methods were fair to good (ICC=.64 and .65, respectively). The inter-rater reliability of the third method was excellent (ICC=.88). Our results suggest that the active adduction test is an objective and qualitative measurement method for measuring iliotibial tract length. We recommend that the active adduction test be used for measuring iliotibial tract length in the clinical setting.

The Reliability of the Pediatric Functional Muscle Testing in Children with Developmental Delay

  • Seo, Hye-Jung;Kim, Joong-Hwi
    • The Journal of Korean Physical Therapy
    • /
    • 제27권4호
    • /
    • pp.183-189
    • /
    • 2015
  • Purpose: The aim of this study was to examine the test-retest and inter-rater reliability of the pediatric functional muscle testing (PFMT) when applied to children with developmental delay. Methods: Sixteen children with developmental delay (seven females, nine males) participated in this study. For the inter-rater reliability, each was scored on the PMFT by two pediatric physical therapists with more than 8 years of clinical experience on the same day. For assessment of the test-retest reliability, one therapist tested the children again within 10 days. The second measurement was performed by taking a first measurement in video. Intraclass correlation coefficient (ICC) was calculated to determine the test-retest and inter-rater reliability of the PFMT, and Chronbach's alpha was used to measure internal consistency. Results: The results of this study were as follows: 1) The test-retest ICC of the score of the infant action month and the right side of the PFMT was from 0.53 to 1.00 and from 0.63 to 0.99, respectively. 2) The inter-rater ICC of the score of the infant action month and the right side of the PFMT was from 0.66 to 1.00 and from 0.64 to 1.00, respectively. 3) Chronbach's alpha was 0.93. The internal consistency indicated excellent. Conclusion: In conclusion, this study showed that the test-retest and inter-rater reliability of the PFMT was relatively high, except for a few items. Therefore, it can be suggested that the PFMT will be a useful tool for measurement of muscle strength for children with developmental delay if it be some modifications.

Reliability of rehabilitative ultrasound imaging for measuring the gluteus maximus muscle at rest and during contraction

  • Jeong, Ju-Ri;Lee, Su-Jin;Lee, Wan-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • 제6권1호
    • /
    • pp.7-13
    • /
    • 2017
  • Objective: The aim of this study was to investigate the inter-rater and intra-rater reliability of rehabilitative ultrasound imaging (RUSI) for measurement of muscle thickness with changes in angles of the gluteus maximus (GM) at rest and during contraction. Design: Cross-sectional study. Methods: Twenty-two healthy men volunteered for this study. GM muscle images were obtained in the resting position and during prone hip extension with knee flexion at hip abduction angles of $0^{\circ}$ and $30^{\circ}$, respectively. Two examiners randomly measured the thickness of the GM twice in three different positions. The first position was a comfortable prone position. The second position was prone hip extension with knee flexion (PHEKF) to $90^{\circ}$. The third position was achieved by hanging a 1-kg weight on the ankle of the lifted leg during PHEKF with the angle of the lifted leg the same as the second position. Intra-class correlation coefficients (ICCs), standard error measurements, and minimal detectable changes were used to estimate reliability. Results: The intra-rater reliability ICCs (95% confidence interval) of the GM were >0.870, indicating good reliability. Inter-rater reliability ICCs ranged from 0.668 to 0.913. The reliability of measurements of muscle thickness at each position was similar to the reliability of the angle change. Differences in muscle thickness and ratios for each position with $0^{\circ}$ and $30^{\circ}$ of hip abduction were not statistically significant. Conclusions: In the present study, the intra-rater reliability of muscle thickness measurements of the GM was good, and the inter-rater reliability was moderate to good. Reliable RUSI measurements of wide and large muscles, such as the GM muscle at rest and during contraction, are feasible. Further investigation is required to establish the reproducibility of the protocols presented in this study.

The Reliability of a Pediatric Balance Scale Based on the Raters' Clinical Work Experience and Test Experience

  • Kim, Gi-Won;Ko, Joo-Yeon;Baek, Soon-Gi
    • The Journal of Korean Physical Therapy
    • /
    • 제22권6호
    • /
    • pp.35-42
    • /
    • 2010
  • Purpose: To investigate the rater reliability of a Pediatric Balance Scale (PBS) for children with cerebral palsy, and to investigate possible differences among raters according to their clinical work experience and testing experience. Methods: Study participants included 18 children with spastic cerebral palsy who could walk. They were instructed by pediatric physical therapists, two of whom had ten years of clinical work experience and two who had less than one year of experience. The children's ability to achieve physical balance was videotaped for PBS items. The raters watched the tapes and evaluated each child twice. Rater reliability was analyzed using the intraclass correlation coefficient (ICC). Differences between experienced and novice raters were analyzed using a paired t-test. The statistical significance level was set to 0.05. Results: The total PBS scores averaged 45.78~48.00 and 45.72~47.67 for first and second tests. Intra-rater reliability was very high (ICC=0.89~0.99), and the repeated measurement coincidence was high (p>0.05). Inter-rater reliability was high (ICC=0.83~0.84), but there was a bit of a difference in the coincidence (p<0.05). The experienced raters' reliability and coincidence were higher than those of the novices, and there were differences in reliance and coincidence between experienced and novice raters (p<0.05). Conclusion: Inter-rater and intra-rater reliability is very high. However, rater reliability showed defferences depending on clinical work experience and testing experience. When testing pediatric patients with the PBS, the rater's clinical experience and test experience may affect the test results.