• 제목/요약/키워드: Intensity-modulated radiation therapy (IMRT)

검색결과 202건 처리시간 0.042초

Intensity-modulated radiotherapy for stage I glottic cancer: a short-term outcomes compared with three-dimensional conformal radiotherapy

  • Cho, Ick Joon;Chung, Woong-Ki;Lee, Joon Kyoo;Lee, Min-Cheol;Paek, Jayeong;Kim, Yong-Hyub;Jeong, Jae-Uk;Yoon, Mee Sun;Song, Ju-Young;Nam, Taek-Keun;Ahn, Sung-Ja;Lee, Dong Hoon;Yoon, Tae Mi;Lim, Sang-Chul
    • Radiation Oncology Journal
    • /
    • 제37권4호
    • /
    • pp.271-278
    • /
    • 2019
  • Purpose: To investigate the differences in treatment outcomes between two radiation techniques, intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3DCRT). Materials and Methods: We retrospectively analyzed 160 (IMRT = 23, 3DCRT = 137) patients with stage I glottic cancer treated from January 2005 through December 2016. The IMRT was performed with TomoTherapy (16 patients), volumetric-modulated arc therapy (6 patients), and step-and-shoot technique (1 patient), respectively. The 3DCRT was performed with bilateral parallel opposing fields. The median follow-up duration was 30 months (range, 31 to 42 months) in the IMRT group and 65 months (range, 20 to 143 months) in the 3DCRT group. Results: The 5-year overall survival and 3-year local control rates of the 160 patients were 95.7% and 91.4%, respectively. There was no significant difference in 3-year local control rates between the IMRT and 3DCRT groups (94.4% vs. 91.0%; p = 0.587). Thirteen of 137 patients in the 3DCRT group had recurrences. In the IMRT group, one patient had a recurrence at the true vocal cord. Patients treated with IMRT had less grade 2 skin reaction than the 3DCRT group, but this had no statistical significance (4.3% vs. 21.2%; p = 0.080). Conclusion: IMRT had comparable outcomes with 3DCRT, and a trend of less acute skin reaction in stage I glottic cancer patients.

The Properties of Beam Intensity Scanner(BInS) in IMRT with Phantom for Three Dimensional Dose Verification

  • Young W. Vahc;Park, Kwangyl;Byung Y. Yi;Park, Kyung R.;Lee, Jong Y.;Ohyun Kwon;Park, Kwangyl;Kim, Keun M.
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.64-64
    • /
    • 2003
  • Objectives: Patient dose verification is clinically the most important parts in the treatment delivery of radiation therapy. The three dimensional(3D) reconstruction of dose distribution delivered to target volume helps to verify patient dose and determine the physical characteristics of beams used in intensity modulated radiation therapy(IMRT). We present Beam Intensity Scanner(BInS) system for the pre treatment dosimetric verification of two dimensional photon intensity. The BInS is a radiation detector with a custom made software for relative dose conversion of fluorescence signals from scintillator. Methods: This scintillator is fabricated by phosphor Gadolinium Oxysulphide and is used to produce fluorescence from the irradiation of 6MV photons on a Varian Clinac 21EX. The digitized fluoroscopic signals obtained by digital video camera will be processed by our custom made software to reproduce 3D relative dose distribution. For the intensity modulated beam(IMB), the BInS calculates absorbed dose in absolute beam fluence, which are used for the patient dose distribution. Results: Using BInS, we performed various measurements related to IMRT and found the followings: (1) The 3D dose profiles of the IMBs measured by the BInS demonstrate good agreement with radiographic film, pin type ionization chamber and Monte Carlo simulation. (2) The delivered beam intensity is altered by the mechanical and dosimetric properties of the collimating of dynamic and/or static MLC system. This is mostly due to leaf transmission, leaf penumbra, scattered photons from the round edges of leaves, and geometry of leaf. (3) The delivered dose depends on the operational detail of how to make multileaf opening. Conclusions: These phenomena result in a fluence distribution that can be substantially different from the initial and calculative intensity modulation and therefore, should be taken into account by the treatment planing for accurate dose calculations delivered to the target volume in IMRT.

  • PDF

전립샘암의 방사선 치료 시 입체조형치료법와 세기조절방사선 치료법의 비교 (A Comparison between Three Dimensional Radiation Therapy and Intensity Modulated Radiation Therapy on Prostate Cancer)

  • 김영재;이재섭;홍성일;고혜진
    • 한국방사선학회논문지
    • /
    • 제7권6호
    • /
    • pp.409-414
    • /
    • 2013
  • 본 연구에서는 전립샘암 환자에게 방사선 치료법인 3차원 입체조형법과 세기조절치료법을 각각 적용 할 경우 선량분포의 차이를 관찰하여 치료기법의 우수성을 평가하고자 하였다. 실험대상자 10명의 컴퓨터 단층 모의치료영상을 얻어 종양학과 전문의가 종양용적 및 정상장기를 구분하고 종양용적에 흡수선량을 80 Gy로 설정한 후 각각 다른 치료계획을 수립하였다. 그 결과 선량분포윤곽은 세기조절치료법이 우수 하였고 종양조직의 흡수선량은 세기조절치료법이 처방선량에 근접(100.2%)하였으며 정상조직 흡수율(방광, 직장, 소장, 좌 우 대퇴골두) 또한 우수하였다. 즉, 전립샘암의 방사선 치료시 세기조절방사선치료가 입체조형치료법보다 선량적인 면에서 양호한 것으로 분석되었다.

원발성 폐암에서 정위적 체부 방사선치료의 빔 배열에 따른 선량분포의 비교 (Comparison of the Dose Distributions with Beam Arrangements in the Stereotactic Body Radiotherapy (SBRT) for Primary Lung Cancer)

  • 예지원
    • 한국의학물리학회지:의학물리
    • /
    • 제25권2호
    • /
    • pp.110-115
    • /
    • 2014
  • 원발성 폐암의 정위적 체부 방사선치료(Stereotatic Body Radiation Therapy; SBRT)시에, 종양주위의 빔 배열을 균등하게 한 $360^{\circ}$회전각도(Equally angles; EA)와 종양주위의 빔 배열을 부분각도(Partially angles; PA)로 배열한 치료계획의 선량차이를 확인하기 위하여, 세기조절방사선치료(Intensity-modulated radiation therapy, IMRT)와 체적변조회전치료(Volumetric-modulated arc therapy, VMAT)의 종양의 선량, 동측 폐의 선량, 반대측 폐의 선량, 손상위험장기(Organ at risk, OAR)의 선량, 치료효율 등을 비교분석 하였다. 12명의 환자에서 각각 4종류($IMRT_{EA}$, $IMRT_{PA}$, $VMAT_{EA}$, $VMAT_{PA}$)의 치료계획을 생성하였으며, 처방선량은 총 선량 60 Gy, 4회 분할치료로 표적체적 95%에 대해 100% 선량이 포함되게 하였다. IMRT와 VMAT의 치료계획 평가에서 $360^{\circ}$회전각도의 빔 균등배열과 부분각도 빔 배열에서 변수중 선량일치지수, 균질성지수, 고선량 유출, $D_{2cm}$, $R_{50}$은 빔 배열에 따라 크게 차이가 나지 않았다. 또한 손상위험장기인 척수, 기관지, 식도의 최고선량은 각각의 방법에 따라 차이를 나타내었다. 특히 $HDS_{location}$에서 21.63%와 26.46%의 큰 차이를 나타내었다.

Dose Verification of Intensity Modulated Radiation Therapy with Beam Intensity Scanner System

  • Vahc, Young-Woo;Park, Kwangyl;Ohyun Kwon;Park, Kyung-Ran;Lee, Yong-Ha;Yi, Byung-Yong;Kim, Sookil
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.248-251
    • /
    • 2002
  • The intensity modulated radiation therapy (IMRT) with a multileaf collimator (MLC) requires the conversion of a radiation fluence map into a leaf sequence file that controls the movement of the MLC during radiation treatment of patients. Patient dose verification is clinically one of the most important parts in the treatment delivery of the radiation therapy. The three dimensional (3D) reconstruction of dose distribution delivered to the target helps to verify patient dose and to determine the physical characteristics of beams used in IMRT. A new method is presented for the pretreatment dosimetric verification of two dimensional distributions of photon intensity by means of Beam Intensity Scanner System (BISS) as a radiation detector with a custom-made software for dose calculation of fluorescence signals from scintillator. The scintillator is used to produce fluorescence from the irradiation of 6MV photons on a Varian Clinac 21EX. The BISS reproduces 3D- relative dose distribution from the digitized fluoroscopic signals obtained by digital video camera-based scintillator(DVCS) device in the IMRT. For the intensity modulated beams (IMBs), the calculations of absorbed dose are performed in absolute beam fluence profiles which are used for calculation of the patient dose distribution. The 3D-dose profiles of the IMBs with the BISS were demonstrated by relative measurements of photon beams and shown good agreement with radiographic film. The mechanical and dosimetric properties of the collimating of dynamic and/or step MLC system alter the generated intensity. This is mostly due to leaf transmission, leaf penumbra and geometry of leaves. The variations of output according to the multileaf opening during the irradiation need to be accounted for as well. These phenomena result in a fluence distribution that can be substantially different from the initial and calculative intensity modulation and therefore, should be taken into account by the treatment planning for accurate dose calculations delivered to the target volume in IMRT.

  • PDF

The Role of Intensity Modulated Radiotherapy in Cancer Treatment

  • Cheung, Kin-Yin
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.6-8
    • /
    • 2002
  • Intensity modulated radiotherapy (IMRT) is an advanced but expensive form of 3-dimensional conformal radiation therapy technique. While the initial clinical data appear to be promising for some treatment sites, the cost effectiveness of the treatment modality has yet to be justified by long-term clinical outcome. This presentation reviews the potential efficacy and limitation of IMRT in respect of the practicality, dosimetry, and resource aspects. It tries to explore and draw conclusions on the strategies for using this sophisticated and expensive treatment technique from AFOMP perspective.

  • PDF

유방암의 접선조사 시 Field-in-Field Intensity Modulated Radiation Therapy와 Conventional Radiation Therapy의 전산화 치료계획에 관한 고찰 (A Comparison of Field-in-Field Intensity Modulated Radiation Therapy Planning and Conventional Radiation Therapy Planning with Tangential Beam for Breast Cancer)

  • 유순미;염미숙;김대섭;백금문;권경태
    • 대한방사선치료학회지
    • /
    • 제22권1호
    • /
    • pp.41-46
    • /
    • 2010
  • 목 적: 유방암의 접선조사 시 쐐기필터를 이용한 Conventional RT 기법과 정적다엽조리개를 이용한 FiF-IMRT 기법을 이용하여 전산화 치료계획 시 발생하는 선량분포의 차이를 환자의 유방 크기와 형태에 따라 분류하여 비교 분석하고자 한다. 대상 및 방법: 유방암 환자 30명을 대상으로 Eclipse treatment planning system ($Varian^{TM}$, USA, V8.0)을 사용하여 전산화 치료 계획을 시행하여 유방의 크기와 형태에 따라 분류하고, Dose Volume Histogram (DVH)을 이용하여 Conformity Index (CI)와 Homogeneity Index (HI)를 비교 분석하였다. 결 과: CI값은 ${\pm}1.2%$의 차이를 나타냈으며 FiF-IMRT의 경우 Conventional RT보다 HI값이 평균 1.67% 낮은 값으로 유방의 크기와 형태에 따른 분류값과 ${\Delta}HI$ (%)값의 상관관계를 알아본 결과 단면길이와 부피에서 높은 상관관계를 보였으며 통계적으로 유의(P<0.01)하였다. 결 론: 유방의 단면 길이와 부피가 증가할수록 Conventional RT의 경우보다 FiF-IMRT로 전산화 치료계획 시 유방 내의 선량 균등성이 향상되었으며 유방의 크기에 따라 그 효과가 다르므로 유방의 크기에 따른 적절한 치료계획이 필요할 것으로 생각된다.

  • PDF

세기조절방사선치료를 이용한 뇌종양에서 에너지 의존성에 관한 연구 (Study of Energy Dependency in Intensity Modulated Radiation Therapy of Brain Tumor)

  • 김성규
    • 한국의학물리학회지:의학물리
    • /
    • 제13권2호
    • /
    • pp.104-108
    • /
    • 2002
  • 세기조절방사선치료(Intensity Modulated Radiation Therapy, IMRT)는 기존의 방사선치료에 비해 암조직에는 더 많은 선량을 조사하면서, 주위 정상조직과 중요 장기에는 더 적은 선량이 조사되게 하는 가장 이상적인 치료법 중 하나로 알려져 있다. 뇌종양에서 치료계획자의 의도대로 세기조절방사선치료계획을 시행하여 4 MV, 6 MV, 15 MV의 에너지에 따른 선량분포 특성과 DVH를 살펴보았다. 종양 표적이 있는 오른쪽 뇌간에서 최대 조사선량은 4 MV, 6 MV, 15 MV에서 4 MV에 대해 10.1%, 8.4%의 차이를, 오른쪽 눈에서는 5.2%, 2.7%의 차이를 나타내고 있지만, 왼쪽 뇌간과 눈, 그리고 시신경 교차와 뇌간은 1.7%에서 5.2%의 차이를 나타내었다. 뇌종양에서 세기조절방사선치료계획을 수행한 결과 4 MV, 6 MV, 15 MV의 에너지의 차이에 따른 선량분포특성과 DVH를 비교검토 해본 결과 PTV와 특정 장기에 조사되는 방사선량이 1.7%에서 10.1% 까지 차이를 나타내었지만, 이것은 한 지점에 조사되는 선량이며, 전체적인 비교에서 본다면 세기방사선치료계획을 시행한 9문 조사에서 에너지의 의존성이 없는 것으로 사료된다.

  • PDF

전립선 암 환자의 IMRT, USPT, 및 IMPT 기법에 따른 치료효과 비교 (Comparison of Intensity-modulated Radiation Therapy (IMRT), Uniform Scanning Proton Therapy (USPT), and Intensity-modulated Proton Therapy (IMPT) for Prostate Cancer: A Treatment Planning Study)

  • 손기홍;조승룡;김진성;한영이;주상규;안성환;신은혁;신정석;박원;표홍렬;최두호
    • 한국의학물리학회지:의학물리
    • /
    • 제24권3호
    • /
    • pp.154-161
    • /
    • 2013
  • 본 연구는 총 10명의 전립선 암 환자를 대상으로 세기조절방사선치료(IMRT), 균일스캐닝양성자치료(USPT), 그리고 세기조절양성자치료(IMPT)기술을 이용한 치료계획의 결과를 비교, 평가 하였다. 각 치료 계획은 타깃 체적의 95%에 70 Gy가 28회 분할 조사되도록 하였으며 세기조절방사선치료(IMRT)에서는 step-and-shoot 기법을 이용하여 총 7개의 빔을 사용하여 방사선을 조사하였고, 균일세기양성자치료(USPT)와 세기조절양성자치료(IMPT)에서는 동일한 방사선 가중치의 측방향대향조사면(lateral opposing field)를 사용하여 타깃에 처방선량이 전달되도록 하였다. 한편, 세기조절양성자치료(IMPT)의 최적화를 위해 IMRT치료와 유사한 Inverse planning을 수행하였다. 결과 비교를 위해 타깃의 균질성지수(homogeneity index) 및 동형지수(conformity index)와 정상조직의 정상조직합병증확률(NTCP)을 계산하였다. 비록 치료기법간에 균질성지수(homogeneity index), 동형지수(conformity index)차이가 크지 않았지만, 직장의 경우 각 세기조절방사선치료(IMRT), 균일스캐닝 양성자치료(USPT) 및 세기조절양성자치료(IMPT)에서 2.233, 3.326 및 1.707로 계산되었다. 또한 방광의 정상조직합병증확률(NTCP)는 0.008, 0.003, 및 0.002를 나타내었다. 직장과 방광의 NTCP 값이 IMPT을 사용할 때 유의하게 낮은 값을 보이는 것을 확인하였다. 본 연구를 통해 전립선 암의 방사선 치료 시 세기조절방사선치료(IMRT)보다 양성자를 이용한 방사선 치료, 특히 최적화된 세기조절양성자치료(IMPT)가 치료 효과를 높일 수 있는 치료계획이 될 수 있음을 확인할 수 있었다.