A Comparison of Field-in-Field Intensity Modulated Radiation Therapy Planning and Conventional Radiation Therapy Planning with Tangential Beam for Breast Cancer

유방암의 접선조사 시 Field-in-Field Intensity Modulated Radiation Therapy와 Conventional Radiation Therapy의 전산화 치료계획에 관한 고찰

  • Yoo, Soon-Mi (Department of Radiation Oncology, Asan Medical Center) ;
  • Yeom, Mi-Suk (Department of Radiation Oncology, Asan Medical Center) ;
  • Kim, Dae-Sup (Department of Radiation Oncology, Asan Medical Center) ;
  • Back, Geum-Mun (Department of Radiation Oncology, Asan Medical Center) ;
  • Kwon, Kyeong-Tae (Department of Radiation Oncology, Asan Medical Center)
  • 유순미 (서울아산병원 방사선종양학과) ;
  • 염미숙 (서울아산병원 방사선종양학과) ;
  • 김대섭 (서울아산병원 방사선종양학과) ;
  • 백금문 (서울아산병원 방사선종양학과) ;
  • 권경태 (서울아산병원 방사선종양학과)
  • Received : 2009.12.01
  • Accepted : 2010.02.16
  • Published : 2010.03.31

Abstract

Purpose: To analyze differences in the dose uniformity for the computed breast radiation therapy planning with tangential beam between conventional RT using wedge filter and FiF-IMRT using multileaf collimator based onsizes and volumes of breasts. Materials and Methods: Thirty breast cancer patients were classified according to the sizes and volumes of the breasts using Eclipse treatment planning system ($Varian^{TM}$, USA, V8.0). Conformity Index and Homogeneity Index were computed along with Dose Volume Histogram. Results: No differencein CI (${\pm}1.2%$) was observed. However, lower mean HI (1.67%) in FiF-IMRT was observed compared to that of the conventional RT. Statically significant (P<0.01) correlation was identified between the values of ${\Delta}HI$ (%) and physical parameters such as breast volumes and separations. Conclusion: Increase in breast volume and separation improves the dose uniformities in computed radiation therapy planning for FiF-IMRT. Physical dimension of the breast should be considered to optimize the compured radiation therapy planning.

목 적: 유방암의 접선조사 시 쐐기필터를 이용한 Conventional RT 기법과 정적다엽조리개를 이용한 FiF-IMRT 기법을 이용하여 전산화 치료계획 시 발생하는 선량분포의 차이를 환자의 유방 크기와 형태에 따라 분류하여 비교 분석하고자 한다. 대상 및 방법: 유방암 환자 30명을 대상으로 Eclipse treatment planning system ($Varian^{TM}$, USA, V8.0)을 사용하여 전산화 치료 계획을 시행하여 유방의 크기와 형태에 따라 분류하고, Dose Volume Histogram (DVH)을 이용하여 Conformity Index (CI)와 Homogeneity Index (HI)를 비교 분석하였다. 결 과: CI값은 ${\pm}1.2%$의 차이를 나타냈으며 FiF-IMRT의 경우 Conventional RT보다 HI값이 평균 1.67% 낮은 값으로 유방의 크기와 형태에 따른 분류값과 ${\Delta}HI$ (%)값의 상관관계를 알아본 결과 단면길이와 부피에서 높은 상관관계를 보였으며 통계적으로 유의(P<0.01)하였다. 결 론: 유방의 단면 길이와 부피가 증가할수록 Conventional RT의 경우보다 FiF-IMRT로 전산화 치료계획 시 유방 내의 선량 균등성이 향상되었으며 유방의 크기에 따라 그 효과가 다르므로 유방의 크기에 따른 적절한 치료계획이 필요할 것으로 생각된다.

Keywords