• Title/Summary/Keyword: Intensity limit

Search Result 362, Processing Time 0.024 seconds

Magnetic Properties of Oxide Superconducting Material (산화물 초전도체의 자기적 특성)

  • Lee, Sang-Heon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.115-118
    • /
    • 2003
  • The sensor at liquid nitrogen temperature showed the increase of electrical resistance by applying magnetic field. Actually, the voltage drop across the sensor was changed from zero to a value more than $100\;{\mu}V$ by the applied magnetic field. The change of electrical resistance depended on magnetic field. The sensitivity of this sensor was $2.9\;{\Omega}/T$. The sensing limit was about $1.5{\times}10^{-5}\;T$. The increase of electrical resistance by the magnetic field was ascribed to a modification of the Josephson junctions due to the penetrating magnetic flux into the superconducting material. Considering the observed properties of the superconductor with trapped magnetic flux, a magnetic sensor was fabricated to detect simultaneously both the intensity and the direction of the magnetic field.

  • PDF

Fatigue Crack Behavior of Triple Piece Spot by Crack Tip Opening Angle of Welded Specimen (3중 점용접재의 귤열단 열림각(CTOA)을 이용한 피로균열거동)

  • Song, Sam-Hong;Joo, Dong-Ho;Yang, Yun-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.5
    • /
    • pp.74-83
    • /
    • 2001
  • In this study, internal fatigue crack initiation and propagation behavior were investigated by triple piece spot welded specimen. To estimate fatigue life of the specimen varied with shape and thickness, Crack tip opening angle(CTOA) correlated with stress intensity factor was used as the stiffness parameter. The relation between fatigue life and CTOA can be arranged by the quantitative equation for each specimen by experiment. In addition, the variation of stress distribution was solved and the effect on fatigue crack behavior was examined by finite element method(FEM).

  • PDF

Challenges in the development of the ultrafast electron microscope (초고속 전자 현미경의 개발과 극복 과제)

  • Park, Doo Jae
    • Vacuum Magazine
    • /
    • v.2 no.1
    • /
    • pp.17-20
    • /
    • 2015
  • In this article, a historical and scientific review on the development of an ultrafast electron microscope is supplied, and the challenges in further improvement of time resolution under sub-picosecond or even sub-femtosecond scale is reviewed. By combining conventional scanning electron microscope and femtosecond laser technique, an ultrafast electron microscope was invented. To overcome its temporal resolution limit which originates from chromatic aberration and Coulomb repulsion between individual electrons, a generation of electron pulse via strong-field photoemission has been investigated thoroughly. Recent studies reveal that the field enhancement and field accumulation associated with the near-field formation at sharply etched metal nanoprobe enabled such field emission by ordinary femtosecond laser irradiation. Moreover, a considerable acceleration reaching 20 eV with near-infrared laser and up to 300 eV acceleration with mid-infrared laser was observed, and the possibility to control the amount of acceleration by varying the incident laser pulse intensity and wavelength. Such findings are noteworthy because of the possibility of realizing a sub-femtosecond, few nanometer imaging of nanostructured sample.in silicon as thermoelectric materials.

Direct Aerosol Analysis by Time Resolved Laser Plasma Spectroscopy - Improvement by Single Shot Measurements

  • Schechter, Israel
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.779-786
    • /
    • 1995
  • Environmental and industrial aerosols can be analyzed on-line by laser plasma spectroscopy. The main problem in direct (no preparation or presorting) aerosol analysis is the extensive spectral fluctuations. A method to partially solve this problem is proposed. It is based on single shot measurements and application of a special rejection algorithm. The major factors that influence the spectral variations are discussed, in relation to the correction possibility by a rejection program. The method works well when average intensity of the single spectra is relatively high, as compared to detector's saturation limit. If intensities are too low, the accumulation of readout noise is critical, and no improvement is expected.

  • PDF

A Study of Small Fatigue Crack Measurement and Crack Growth Characteristics (미소균열측정과 성장특성에 관한 연구)

  • Lee, Jong-Hyung;So, Yoon-Sub;Kim, Yun-Gon;Lim, Chun-Kyoo;Lee, Sang-Young
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.10 no.1
    • /
    • pp.39-46
    • /
    • 2007
  • The objective of this paper is to examine the detection limit, growth characteristics and notch curvature radius in short crack problem. Measurement techniques such as ultrasonic method and back-face strain compliance method were adapted. The fatigue crack growth rate of the short crack is slower than that of a long crack for a notched specimen. The short crack is detected effectively by ultrasonic method. A short surface crack occurs in the middle of specimen thickness and is transient to a through crack when maximum crack depth is larger than the notch curvature radius.

  • PDF

Enhancement in quantum noise correlation between the two outputs of a nondegenerate optical amplifier with a non-vacuum state idler input

  • Kim, Chong-Hoon
    • Journal of the Optical Society of Korea
    • /
    • v.1 no.1
    • /
    • pp.1-4
    • /
    • 1997
  • The theoretical limit of the noise correlation between the signal and idler outputs of a nondegenerate optical parametric amplifier (NOPA) with a coherent state signal and vacuum state idler input can be enhanced if a non-vacuum coherent state idler input is employed. By choosing a balanced signal and idler input, the noise correlation is $1/{({\root}g + {\root}{g-1})}^2$, where g is the intensity gain of the NOPA, and that is superior to the prediced outputs with single signal input by approximately 3dB. The result is applicable to all the schemes that use the NOPA to produce a sub-shot noise light generation such as feed-back or feed-forward control.

p-Version Finite Element Analysis of Cracked Panels Based on Linear Elastic Fracture Mechanics (선형탄성파괴역학 이론에 의한 균열판의 p-Version 유한요소해석)

  • 윤영필;우광성;박병기;신영식
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1993.04a
    • /
    • pp.19-26
    • /
    • 1993
  • The p-version crack model based on integrals of Legendre polynomial and virtual crack extension method is proposed with its potential for application to stress intensity factor computations in linear elastic fracture mechanics. The main advantage of this model is that the data preparation effort is minimal because only a small number of elements are used and the high accuracy and the rapid rate of convergence can be achieved in the vicinity of crack tip. There are two important findings from this study. Firstly, the limit value, the strain energy of the exact solution can be estimated with successive three p-version approximations by ascertaining the approximations is entered the asymptotic range. Secondly, the rate of convergence of p-version model is almost twice that of h-version model on the basis of uniform or quasiuniform mesh refinement for the cracked panel problem subjected tension.

  • PDF

Determination of Microamounts of Copper by Fluorescence X-Ray Analysis (형광 X-선 분석에 의한 미량 구리의 정량)

  • Choi Won-hyung;Kim Chan-ho
    • Journal of the Korean Chemical Society
    • /
    • v.16 no.6
    • /
    • pp.373-377
    • /
    • 1972
  • The analytical conditions for the fluorescence X-ray determination of small amount of cupper in solution were established. Copper in solution was extracted by diethyldithiocarbamate ethyl acetate and adsorbed by zinc powder. After drying, it was pressed to tablet under the pressure of $250Kg/cm^2.$$K_{\alpha}2(2{\theta}_{LiF} = 45.08^{\circ})$. The limit of detection was estimated to be about $10{\mu}g$ by the method of standard addition with an error of 10 %.

  • PDF

Determination of Bovine Serum Albumin by Its Enhancement Effect of Nile Blue Fluorescence

  • Lee, Sang-Hak;Suh, Jung-Kee;Li, Ming
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.1
    • /
    • pp.45-48
    • /
    • 2003
  • A novel fluorimetric method has been developed for the determination of microgram quantities of bovine serum albumin (BSA) based on its enhancement effect of Nile Blue fluorescence at 670 nm, caused by binding of Nile Blue to BSA to produce a stable water soluble complex. The binding constant of micromole Nile Blue-BSA complex was estimated by Scatchard plot method. Under the optimal conditions, the increased fluorescence intensity was linearly related to BSA concentration in the range of 0.5-12.0 ㎍/mL. The detection limit was 0.2 ㎍/mL, and the relative standard deviation of six replicate measurements was 1.4% for 10.0 ㎍/mL BSA. There was little interference from amino acids, sugars and most of metal ions.

Magnetic Sensor by Using Magnetic Effect in YBaCuO Superconductor

  • 이상헌;김찬중
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.69-71
    • /
    • 2003
  • The magnetic field sensor was fabricated with superconducting ceramics of YBaCuO system. The sensor at liquid nitrogen temperature showed the increase of electrical resistance by applying magnetic field. Actually the voltage drop across the sensor was changed from zero to a value more than 100 $mutextrm{V}$ by the applied magnetic field. The change in electrical resistance depended on magnetic field. The sensitivity of this sensor was 2.9 $\Omega$/T. The sensing limit was about $1.5\times$10$^{-5}$. The increase of electrical resistance by the magnetic field was ascribed to a modification of the Josephson junctions due to the penetrating magnetic flux into the superconducting material. Considering the observed properties of the superconductor with trapped magnetic flux, a magnetic sensor was fabricated to detect simultaneously both the intensity and the direction of the magnetic field.

  • PDF