• Title/Summary/Keyword: Intensity Correction

Search Result 195, Processing Time 0.031 seconds

The isobaric effect correction and measurement of the Ru isotopes by thermal ionization mass spectrometry (열 이온화 질량분석기를 이용한 Ru 동위원소 측정 및 동중원소 영향 보정)

  • Jeon, Young-Shin;Kim, Jung-Suk;Han, Sun-Ho;Song, Kyu-Seok
    • Analytical Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.498-504
    • /
    • 2010
  • It is very difficult to get stable ion peak intensity of ruthenium by thermal ionization mass spectrometry because of its high ionization potential and high volatility of its oxides which causes to lose much of ruthenium ions, so the intensity of the signal decrease quickly. Accordingly, a study was performed in oder to increase the ionization efficiency and to prevent sample losses due to volatilization and to check with isobaric effect by impurities in filament for the measurement of ruthenium isotopes. Both single filament and double filament were tested. The former was proved to be more efficient for the stable and strong intensity of signal and revealed less isobaric effect from the molybdenum (Mo) as a filament impurity. Also, when the temperature of filament increased too high, the isobaric effect from Mo greatly appeared. That is, Mo impurity from filament gave a serious effect for measuring the ruthenium isotopes. It was proved to be of importance that filament current should be slowly increased with time interval. Finally, ruthenium isotopes were accurately measured by correction with measuring $^{94}Mo/^{99}Ru$.

Research on the optimization of off-axis illumination condition and sub-resolution pattern size for the $0.1{\mu}m$ rule dense pattern formation ($0.1{\mu}m$급 dense 패턴 형성을 위한 사입사 조명 조건과 OPC 보조 패턴 크기의 최적 조건에 관한 연구)

  • 박정보;이재봉;이성묵
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.3
    • /
    • pp.190-199
    • /
    • 2001
  • In this paper, we have researched the depth of focus (DOF) and cutoff intensity of the $0.1{\mu}m$rule dense line'||'&'||'space pattern according to the various off-axis illumination (OAl) conditions in the optical system of 0.65 NA using ArF excimer laser (193 nm). We have also studied the variation of the DOF and cutoff intensity according to the sub-resolution pattern (hammer head type) size for optical proximity correction (OPC) applied to the capacitor pattern and the various OAl conditions in the same optical system. As a result, it is revealed that the cross type quadrupole or annular illumination is preferred to the conventional X type quadrupole for printing the $0.1{\mu}m$ rule dense pattern. Also, we can investigate the optimal illumination condition and the size of ope sub-resolution pattern to keep a consistent DGF and cutoff intensity trends.

  • PDF

Modified parity coding for digital holographic data storage system with spatial beam intensity variations (공간적 빔 세기 불 균일성을 가지는 디지털 홀로그래픽 데이터 저장 시스템을 위한 수정된 패리티 코딩)

  • Choi, An-Sik;Jun, Young-Sik;Baek, Woon-Sik
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.2
    • /
    • pp.150-154
    • /
    • 2003
  • In this paper, we introduce modified parity coding methods to reduce the errors caused by spatial beam intensity variations in a holographic data storage system. We explained the encoding and decoding process of the conventional parity coding and the modified parity coding techniques. We compared the bit-error-rate (BER) performances of the conventional parity coding and the modified parity coding techniques from experimental evaluation.

Assessment of Attenuation Correction Algorithms With a $^{137}$Cs Point Source (Cs-137 점선원을 이용한 감쇠보정기법들에 대한 평가)

  • Bong, Jung-Kyun;Kim, Hee-Joung;Park, Hae-Jung;Kwon, Yun-Youn;Son, Hye-Kyoung;Yun, Mi-Jin;Lee, Jong-Doo;Jung, Hae-Jo
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.96-99
    • /
    • 2004
  • The objective of this study is to assess attenuation correction algorithms utilized in a multipurpose whole-body GSO PET scanner. Four different types of phantoms were tested using different types of attenuation correction techniques. FOV (Field of View) of 256mm was used for brain PET imaging. For compensating attenuation, transmission data of a $^{137}$Cs point source were acquired after the F-18 emission source was infused to the phantoms. Scatter correction were peformed. Reconstructed images of the phantoms were assessed. In addition, reconstructed images of a normal subject were compared and assessed by nuclear medicine physicians. As a result, decreased intensity at the central portion of the attenuation map with cylindrical phantom was noticed during use of the measured attenuation correction. On the other hand, segmentation or remapping attenuation correction provided uniform phantom image. the images reconstructed from the clinical brain data explained the attenuation of a skull, at though reconstructed images of the phantoms couldn't explain it. in conclusion, the complicated and improved attenuation correction methods were required to obtain the better accuracy of the quantitative brain PET images. Our study will be useful in improving quantitative brain PET imaging modalities with attenuation correction of $^{137}$Cs transmission source.

  • PDF

Enhancement on Time-of-Flight Camera Images (Time-of-Flight 카메라 영상 보정)

  • Kim, Sung-Hee;Kim, Myoung-Hee
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.708-711
    • /
    • 2008
  • Time-of-flight(ToF) cameras deliver intensity data as well as range information of the objects of the scene. However, systematic problems during the acquisition lead to distorted values in both distance and amplitude. In this paper we propose a method to acquire reliable distance information over the entire scene correcting each information based on the other data. The amplitude image is enhanced based on the depth values and this leads depth correction especially for far pixels.

  • PDF

Eletromyographic Activities of Trunk and Lower Extremity Muscles During Bridging Exercise in Whole Body Vibration and Swiss Ball Condition in Elderly Women

  • Kim, Tack-Hoon;Lee, Kang-Seong
    • Physical Therapy Korea
    • /
    • v.17 no.4
    • /
    • pp.26-34
    • /
    • 2010
  • The purpose of this study was to compare the trunk and lower extremity muscle activity induced by six different conditions floor, intensity 0, 1, 3, 5 of whole body vibration (WBV), and Swiss ball during bridging exercise. Surface electromyography (EMG) was used to measure trunk and lower extremity muscles activity. Ten elderly women were recruited from Hong-sung Senior Citizen Welfare Center. The collected EMG data were normalized using reference contraction (during floor bridging) and expressed as a percentage of reference voluntary contraction (%RVC). To analyze the differences in EMG data, the repeated one-way analysis of variance was used. A Bonferroni's correction was used for multiple comparisons. The study showed that EMG activity of the rectus abdominis, external oblique, internal oblique, erector spinae and rectus abdominis muscles were not significantly different between six different conditions of during bridging exercise (p>.05). However, there were significantly increased EMG activity of the rectus femoris (p=.034) in the WBV intensity 0, 1, 3, and 5 conditions compared with the floor bridging condition. EMG activity of the medial gastrocnemius were significantly increased in the WBV intensity 0, 1, 3, 5 and Swiss ball conditions compared with the floor bridging condition. Future studies are required the dynamic instability condition such as one leg lifting in bridging.

Error and Correction Schemes of Control Volume Radiative Energy with the Discrete Ordinates Interpolation Method (제어체적 복사열정산을 위한 구분종좌표보간법의 오차 및 보정방안)

  • Cha, Ho-Jin;Song, Tae-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.6
    • /
    • pp.796-803
    • /
    • 2003
  • The discrete ordinates interpolation method (DOIM) has shown good accuracy and versatile applicability for the radiation $problems^{(1,2)}$. The DOIM is a nonconservative method in that the intensity and temperature are computed only at grid points without considering control volumes. However, when the DOIM is used together with a finite volume algorithm such as $SIMPLER^{(3)}$, intensities at the control surfaces need to be calculated. For this reason, a 'quadratic' and a 'decoration' schemes are proposed and examined. They are applied to two kinds of radiation problem in one-dimensional geometries. In one problem, the intensity and temperature are calculated while the radiative heat source is given, and in the other, the intensity and the radiative heat source are computed with a given temperature field. The quadratic and the decoration schemes show very successful results. The quadratic scheme gives especially accurate results so that further decoration may not be needed. It is recommended that the quadratic and the decoration schemes may be used together, or, one of them may be applied for control volume radiative energy balance.

Effect of Bong Chuna Manual Treatment Combined with Oriental Medical Treatment on Posterior Inferior Ilium Deviation ; 3 Cases Report (봉추나요법과 한방치료를 병행한 후하방장골 변위 교정 3예)

  • Oh, Won-Kyo;Shin, Byung-Cheul
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.18 no.1
    • /
    • pp.173-185
    • /
    • 2008
  • Objectives : The purpose of this study was to observe the effect of Bong (a type of stick which is called bong) Chuna manual therapy (CMT) on the correction of posterior inferior (PI) ilium deviation, and evaluate changes of pain intensity and Oswestry Disability Index (ODI) for the treatment of low back pain. Methods : We measured leg length inequality (LLI), as an indicator of correction of PI ilium, before and after the Bong CMT twice immediately, and also checked the change of LLI in the course of 10 times of treatment. Ten times of Bong CMT with oriental medical treatment, such as acupuncture and bee venom pharmacopuncture, were performed not only to correct the PI ilium deviation but also to alleviate pain. Visual Analog Scale (VAS) and Oswetry Low-back Pain Disability Index (ODI) score were scored to evaluate the pain and function of low back. Results : In this study, LLI was decreased in general while we performed correction of PI ilium deviation immediately, also effectively decreased comparing between before and after 10 times of Bong CMT, Bong CMT with oriental medical treatment improved pain and function of low back. Conclusions : These results suggest that Bong CMT may be an effective method for the correction of PI ilium deviation. However more rigorous study should be followed because of small cases report.

A Study on the Noise Correction Factor in Apartment Complex (공동주택에서의 소음보정계수에 관한 연구)

  • Lee, Nae Hyun;Sunwoo, Young;Park, Young Min;Park, Sun Hwan;Cho, Il-Hyoung
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.5
    • /
    • pp.247-254
    • /
    • 2005
  • Road traffic noise has increasing broader effects on urban areas as well as rural areas because of rapidly increasing traffic volume and newly-constructed roads. 10 sites in building development areas were selected and the noise level were measured by the apartment floors and by the various block plans of apartment complex. Analysis result, about correction factor, in the case of right angle arrangement, apply - 2.5dB(A). In the case of apartment house correlation of each floor apply 1st floors 0dB(A), 2st floors 1.2dB(A), 3st floors 2.1dB(A), 4st floors 2.6dB(A), 5st floors 2.7dB(A), 6st floors 2.7dB(A), 7st floors 2.4dB(A), 8st floors 2.0dB(A), 9st floors 1.6dB(A), 10st floors 1.1dB(A), 13st floors 0.2dB(A), 15st floors 0.5dB(A). The level of road traffic noise in the arrangement construction of right angle was about 3.0dB(A) at N-4 point and 2.1dB(A) at N-6 point lower than that of a plan figure, respectively. The results suggested that application of correction coefficient obtained by the apartment floor and by the arrangement construction can be improved in road traffic noise. The results suggested that application of correction coefficient obtained by the apartment floor and by the arrangement construction can be improved in road traffic noise.

Intra-Rater and Inter-Rater Reliability of Brain Surface Intensity Model (BSIM)-Based Cortical Thickness Analysis Using 3T MRI

  • Jeon, Ji Young;Moon, Won-Jin;Moon, Yeon-Sil;Han, Seol-Heui
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.3
    • /
    • pp.168-177
    • /
    • 2015
  • Purpose: Brain surface intensity model (BSIM)-based cortical thickness analysis does not require complicated 3D segmentation of brain gray/white matters. Instead, this technique uses the local intensity profile to compute cortical thickness. The aim of the present study was to evaluate intra-rater and inter-rater reliability of BSIM-based cortical thickness analysis using images from elderly participants. Materials and Methods: Fifteen healthy elderly participants (ages, 55-84 years) were included in this study. High-resolution 3D T1-spoiled gradient recalled-echo (SPGR) images were obtained using 3T MRI. BSIM-based processing steps included an inhomogeneity correction, intensity normalization, skull stripping, atlas registration, extraction of intensity profiles, and calculation of cortical thickness. Processing steps were automatic, with the exception of semiautomatic skull stripping. Individual cortical thicknesses were compared to a database indicating mean cortical thickness of healthy adults, in order to produce Z-score thinning maps. Intra-class correlation coefficients (ICCs) were calculated in order to evaluate inter-rater and intra-rater reliabilities. Results: ICCs for intra-rater reliability were excellent, ranging from 0.751-0.940 in brain regions except the right occipital, left anterior cingulate, and left and right cerebellum (ICCs = 0.65-0.741). Although ICCs for inter-rater reliability were fair to excellent in most regions, poor inter-rater correlations were observed for the cingulate and occipital regions. Processing time, including manual skull stripping, was $17.07{\pm}3.43min$. Z-score maps for all participants indicated that cortical thicknesses were not significantly different from those in the comparison databases of healthy adults. Conclusion: BSIM-based cortical thickness measurements provide acceptable intra-rater and inter-rater reliability. We therefore suggest BSIM-based cortical thickness analysis as an adjunct clinical tool to detect cortical atrophy.