• Title/Summary/Keyword: Intensity

Search Result 18,373, Processing Time 0.039 seconds

Intensity Characteristics of Korean Obstruents (한국어 장애음의 강도 특성)

  • Park Hansang
    • MALSORI
    • /
    • no.47
    • /
    • pp.73-84
    • /
    • 2003
  • This study investigates differences in intensity across the three different Korean obstruent types in terms of the RMS amplitude of both the entire section and the first 512 samples of the immediately following vowel in two positions. The results showed that for the utterance initial position the RMS amplitude of both the entire section and the first 512 samples of the vowel was greatest for fortis obstruents, intermediate for aspirated ones, and weakest for lenis ones, with a significant difference between each pair of them. For the intervocalic position, in contrast, the intensity of the entire vowel was greatest for fortis obstruents, intermediate for lenis ones, and weakest for aspirated ones, with no significant difference between the last two groups, whereas the intensity of the first 512 samples of the vowel was greatest for fortis obstruents, intermediate for lenis ones, and weakest for aspirated ones, with a significant difference between each pair of the three groups. This means that the intensity of the earlier part of the vowel functions as a discriminator of Korean obstruents. The positional difference is due to the different behavior of the lenis obstruents in the intervocalic position, such that the intensity build-up is already on its way with voice lead.

  • PDF

The Effect of Low-intensity Ultrasound (noblelife) on Pain Relief of Upper Trapezius (저강도 초음파치료기 노블라이프가 상부 승모근 통증에 미치는 영향)

  • Lee, Jao-On;Choi, Jong-Duk;Jung, Nak-Su;Choi, Kyu-Hwan
    • Physical Therapy Korea
    • /
    • v.9 no.2
    • /
    • pp.97-105
    • /
    • 2002
  • The purpose of this study was to investigate the effectiveness of the low-intensity ultrasound (noblelife) treatment on the pain points of upper trapezius muscle. The study recruited 20 patients who had trigger points in one side of the upper trapezius. The effectiveness of the low-intensity ultrasound treatment was assessed with subjective pain intensity using visual analog scale (VAS) and pressure pain threshold (PPT). The PPT was measured by pressure threshold algometer. Before and after the treatment, changes of pain were evaluated. Wilcoxon test for VAS data and paired t-test for PPT data were used for statistical significance. Compared to the pain intensity before the treatment, the pain intensity after treatment was significantly decreased (p<.05). Low-intensity ultrasound could be safely used in clinical application and at home for the treatment of patients with pain in upper trapezius muscle.

  • PDF

Intensity Local Map Generation Using Data Accumulation and Precise Vehicle Localization Based on Intensity Map (데이터 누적을 이용한 반사도 지역 지도 생성과 반사도 지도 기반 정밀 차량 위치 추정)

  • Kim, Kyu-Won;Lee, Byung-Hyun;Im, Jun-Hyuck;Jee, Gyu-In
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.12
    • /
    • pp.1046-1052
    • /
    • 2016
  • For the safe driving of autonomous vehicles, accurate position estimation is required. Generally, position error must be less than 1m because of lane keeping. However, GPS positioning error is more than 1m. Therefore, we must correct this error and a map matching algorithm is generally used. Especially, road marking intensity map have been used in many studies. In previous work, 3D LIDAR with many vertical layers was used to generate a local intensity map. Because it can be obtained sufficient longitudinal information for map matching. However, it is expensive and sufficient road marking information cannot be obtained in rush hour situations. In this paper, we propose a localization algorithm using an accumulated intensity local map. An accumulated intensity local map can be generated with sufficient longitudinal information using 3D LIDAR with a few vertical layers. Using this algorithm, we can also obtain sufficient intensity information in rush hour situations. Thus, it is possible to increase the reliability of the map matching and get accurate position estimation result. In the experimental result, the lateral RMS position error is about 0.12m and the longitudinal RMS error is about 0.19m.

Characteristics of Parameters for the Distribution of Fatigue Crack Growth Lives under Constant Stress Intensity Factor Control (일정 응력확대계수 제어하의 피로균열전파수명 분포의 파라메터 특성에 관하여)

  • Kim, Seon-Jin;Kim, Young-Sik;Jeong, Hyeon-Cheol
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.301-306
    • /
    • 2002
  • The characteristics of parameters for the probability distribution of fatigue crack growth lives by the non-Gaussian random process simulation method is investigated. In this paper, the material resistance to fatigue crack growth is treated as a spatial random process, which varies randomly on the crack surface. Using the previous experimental data, the crack length - the number of cycles curves are simulated. The results are obtained for constant stress intensity factor range conditions with stress ratio of R=0.2, three specimen thickness of 6, 12 and 18mm, and the four stress intensity level. The probability distribution function of fatigue crack growth lives seems to follow the 3-parameter Wiubull and shows a slight dependence on specimen thickness and stress intensity level. The shape parameter, ${\alpha}$, does not show the dependency of thickness and stress intensity level, but the scale parameter, ${\beta}$, and location parameter, ${\upsilon}$, are decreased by increasing the specimen thickness and stress intensity level. The slope for the stress intensity level is larger than the specimen thickness.

  • PDF

Evaluation of Light Intensity and Uniformity of LEDs for Protected Crop Production

  • Kim, MunJung;Choo, YounKug;Kim, YongJoo;Chung, SunOk
    • Agribusiness and Information Management
    • /
    • v.6 no.1
    • /
    • pp.37-44
    • /
    • 2014
  • This study was conducted to evaluate light intensity and uniformity of two SMD (surface-mount device) type LEDs for protected crop production. A low-power (0.1 W) and a high-power (1 W) LEDs were selected and the intensity and uniformity was evaluated at different vertical (height) and horizontal (distance) intervals. When the horizontal interval of the LED bar was fixed, the light intensity increased and the uniformity decreased as the height decreased. At the 30~40 cm heights, 20~30% of the area showed $200{\pm}20{\mu}molm^{-2}s^{-1}$. As the horizontal distance of the LED bars increased, while the uniformity increased as well, the light intensity decreased. At the distances of 6~10 cm, 17~23% of the area showed $200{\pm}20{\mu}molm^{-2}s^{-1}$. When the LED bars were added to the sides, the light intensity and uniformity were generally improved. Results showed that the light intensity and uniformity depended on the height and interval of the LED bulbs; therefore, optimum arrangement for the crops interested should be determined through experiments.

Effects of Ohmic Thawing on the Physicochemical Properties of Frozen Pork

  • Kim, Jee-Yeon;Hong, Geun-Pyo;Park, Sung-Hee;Lee, Sung;Min, Sang-Gi
    • Food Science and Biotechnology
    • /
    • v.15 no.3
    • /
    • pp.374-379
    • /
    • 2006
  • This study was carried out to investigate the physicochemical properties of frozen pork muscle which has been thawed using the ohmic thawing process, and to establish the optimal ohmic power intensity. The samples were frozen at $-40^{\circ}C$ and thawed at 0, 10, 20, 30, and 40 V by ohmic thawing. Increasing ohmic power intensity correlated with increased thawing rates. The relationship between ohmic power intensity and thawing rate can be represented as a polynomial function. The pH value decreased with increasing ohmic power intensity (p<0.05). With regard to color measurement, the $L^*$, a, and b values of thawing at all ohmic power intensities were not significantly different. The water holding capacity showed a peak value of 41.62% with an ohmic thawing intensity of 30 V. Cooking losses were lowest at the lowest ohmic thawing intensity of 10 V. Thiobarbituric acid reactive substance (TBARS) levels with all thawing processes were slightly higher than that of the control (p<0.05). Increasing ohmic power intensity did not tend to change the total volatile basic nitrogen (TVBN) value.

R&D Intensity and Regulation Fair Disclosure

  • Park, Jin-Ha;Shim, Hoshik
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.6 no.1
    • /
    • pp.281-288
    • /
    • 2019
  • This study examines the relationship between R&D intensity and disclosure. R&D activities are essential in bringing innovation to companies. However, R&D activities are naturally uncertain and increase information asymmetry. Thus, firms with high R&D activities are more likely to have the incentive to communicate the potential of R&D investment to the market through voluntary disclosure and, concurrently, resolve information asymmetry. Meanwhile, incentives to less voluntary disclosure exist because of the proprietary cost and the risk of competitiveness loss. Furthermore, the uncertainties inherent in R&D activities caused the possible decrease in the information accuracy. For the two opposing views, this study investigates the relationship between R&D intensity and disclosure frequency using the Regulation Fair Disclosure data in Korea. Moreover, the relationship between R&D intensity and usefulness of the information disclosed is also examined. Using firm sample listed in the 2011-2016 Korea Stock Market, results show that firms with high R&D intensity make disclosures more frequent. Subsequently, the analysis using forecast sample shows that management forecast error is higher in firms with high R&D intensity. This research contributes to the existing literature by presenting evidence that R&D intensity is a significant factor affecting manager's disclosure behavior and information usefulness.

Dose Intensity of Oxaliplatin in 5-Fluorouracil and Leucovorin Regimens in Pretreated Metastatic Colorectal Cancer (5-Fluorouracil, Leucovorin과 병용 투여된 Oxaliplatin의 Dose Intensity가 재발된 전이성 대장암 치료에 미치는 영향)

  • Jeong, Kyong-Ju;Choi, Seung-Ki;Oh, Jung-Mi
    • Korean Journal of Clinical Pharmacy
    • /
    • v.14 no.1
    • /
    • pp.1-10
    • /
    • 2004
  • Studies of oxaliplatin, 5-fluorouracil and leucovorin in pretreated metastatic colorectal cancer showed that oxaliplatin dose intensity is important prognostic factor for objective response rates and progression-free-survival (PFS). To evaluate response rates, PFS and toxicity according to oxaliplatin dose intensity, we retrospectively analyzed data from patients with metastatic colorectal cancer received oxaliplatin,5-fluorouracil, leucovorin regimens. Sixty-three patients were reviewed in this study, 42 patients received low dose intensity oxaliplatin (LDI: $\leq85\;mg/m^2/2wks$) and 21 patients high dose intensity oxaliplatin (HDI: $>85\;mg/m^2/2wks$). Objective responses occurred in 10 $(47.7\%)$ HDI patients and 9 $(21.4\%)$ LDI patients (p = 0.014). Median PFS was 24.7 weeks in HDI group, with $45.1\%$ of HDI patients progression free at 6 months, and 20.5 weeks in LDI group, with $33.5\%$ of LDI patients progression free at 6 months (p = 0.344). Increased oxaliplatin dose intensity was not associated with neutropenia, thrombocytopenia, neuropathy, nausea and vomiting. This study showed that oxaliplatin dose intensification significantly improves objective response rate in pretreated metastatic colorectal cancer without increasing severe toxicity.

  • PDF

A novel proficient and sufficient intensity measure for probabilistic analysis of skewed highway bridges

  • Bayat, M.;Daneshjoo, F.;Nistico, N.
    • Structural Engineering and Mechanics
    • /
    • v.55 no.6
    • /
    • pp.1177-1202
    • /
    • 2015
  • In this paper, a new intensity measure of earthquakes for probabilistic seismic analysis is presented for skewed highway bridges. Three different cases of skewed bridges with different skew angles ($0^{\circ}$, $30^{\circ}$ and $45^{\circ}$) are considered. Well-known intensity measures (e.g., PGA, $S_a$) are evaluated and critically discussed based on sensitivity analysis: efficiency, practically, proficiency and sufficiency of intensity measures are considered in detail. The analyses demonstrated that the intensity measures have to take into account structural acceleration on a wide range of periods so that a new seismic intensity measure is proposed showing that it has less dispersion compared to others. Since the proposed intensity represents the average value of the $S_a$ (between a lower and upper structural period) it has been called Averaged Spectral Acceleration (ASA). Based on performed incremental dynamic analysis (IDA), the seismic analytical fragility curves of typical skewed highway bridges have been evaluated for different states of damage controlling the low dispersion of the ASA index as well as its proficiency and sufficiency.

The Variation of Sapphire Substrate Shape of Micro LED Array to Increasing of Light Intensity and Contrast Ratio (Light Intensity 및 명암비 향상을 위한 마이크로 LED의 사파이어 기판 형상 변화 연구)

  • Cha, Yu-Jung;Kwak, Joon Seop
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.1
    • /
    • pp.8-15
    • /
    • 2021
  • Micro-LEDs can be applied to various parts of a product. However, it has disadvantages compared to general LEDs in large displays such as low efficiency, intensity, and contrast ratio, among others, owing to their short history of study. The simulations were carried out using ray-tracing software to investigate the change in light intensity and light distribution according to pattern shapes on the sapphire substrate of the flip-chip micro-LED (FC μ-LED) array. Three patterns-concave square patterns, convex square patterns, and Ag coated convex patterns-which existed on the opposite side of FC μ-LEDs (115 ㎛ × 115 ㎛) array, were applied. The intensity of FC μ-LEDs on the center of the receivers depends on the pattern depth with shape. The concave square patterns having FC μ-LEDs arrays show that decreasing intensity as the patterns depth. On the contrary, the convex square patterns having FC μ-LEDs arrays shows that increasing intensity as the patterns depth. In addition, the highest intensity shows that FC μ-LEDs having Ag-coated convex patterns on the opposite side of sapphire lead to a reduction in light crosstalk owing to the Ag film.