Journal of Institute of Control, Robotics and Systems
/
v.6
no.2
/
pp.127-137
/
2000
This paper presents a novel neural based controller which controls the water level of the nuclear power plant steam generator. The controller consists of a model reference feedback linearization controller and a PI controller for stabilizing the feedback linearization controller. The feedback linearization controller consists of a neural network model and an inversing module which uses the neural network model for computing the control input to the steam generator. We chose Piecewise Linearly Trained Network(PLTN) and Recurrent Neural Netwrok(RNN) for an approximator of the plant and used these approximators in calculating the input from the feedback linearization controller. Combining the above two controllers gives a result of better performance than the case which uses only a PI controller Each control result of PLTN and RNN is given.
Cho Su Eog;Choi Cheol;Park Han Woong;Kim Cheol Woo
Proceedings of the KIPE Conference
/
2002.07a
/
pp.542-545
/
2002
This paper deals with the optimization inverter design and minimization Conduced EMI noise by customizing IPM(Intelligent Power Module). Generally, In case of IPM, we realized that the trade-off relation between switching loss and spike voltage. Higher gate resistor causes tile lower spike voltage and the higher turn-off switching loss. But we know that the life cycle of inverter and the susceptibility of noise, so we optimized the gate resistor. Proposed method is that optimized the gate resistor suitable for the inverter and motor. The simulation and experimental results show that the spike voltage and Conduced EMI noise can be reduced without the additional circuit.
Seo Mun-Seok;Bae Jong-Pyo;Choe Jae Hyeok;Kim Jong-Sun;Yoo Ji-Yoon;Yeo Hyeong-Gee
Proceedings of the KIPE Conference
/
2002.07a
/
pp.124-128
/
2002
This Paper propose a novel sensorless drive system for the trapezoidal brushless DC motor in Bow speed region. The inverter DC input voltage is controlled by step-down converter for low speed operation. A indirect rotor position sensing technique based on a detailed analysis of the terminal voltage characterisrics is proposed in this paper. A sensorless drive system is implemented using a TMS320F240 for the main process and IPM(Intelligent Power Module) for the inverter.
In this paper, AC electric vehicle propulsion system(Converter/Inverter) using high power semiconductor, IPM(Intelligent Power module) is proposed. 2-Parallel operation of two PWM converter is adopted for increasing capacity of system and the VVVF inverter control is used a mixed control algorithm, where the vector control strategy at low speed region and slip-frequency control strategy at high speed region. The proposed propulsion system is verified by experimental results with a 1,350kW converter and 1.100kVA inverter with four 210kW traction motors.
The Transactions of the Korea Information Processing Society
/
v.13
no.3
/
pp.111-121
/
2024
Recently, thanks to the development of artificial intelligence technologies such as image recognition, research on unmanned aerial vehicles is being actively conducted. In particular, related research is increasing in the field of military drones, which costs a lot to foster professional pilot personnel, and one of them is the study of an intelligent framework for autonomous mission performance of reconnaissance drones. In this study, we tried to design an intelligent framework for unmanned aerial vehicles using the methodology of designing an intelligent framework for service robots. For the autonomous mission performance of unmanned aerial vehicles, the intelligent framework and unmanned aerial vehicle module must be smoothly linked. However, it was difficult to provide interworking for drones using periodic message protocols with model-based interfaces of intelligent frameworks for existing service robots. First, the message model lacked expressive power for periodic message protocols, followed by the problem that interoperability of asynchronous data exchange methods of periodic message protocols and intelligent frameworks was not provided. To solve this problem, this paper proposes a message model extension method for message periodic description to secure the model's expressive power for the periodic message model, and proposes periodic and asynchronous data exchange methods using the extended model to provide interoperability of different data exchange methods.
Jihyun, Kim;Ju-Hee, Kim;Jeongjun, Lee;Jongsung, Park;Changheon, Kim
Current Photovoltaic Research
/
v.10
no.4
/
pp.133-137
/
2022
The economic feasibility of a photovoltaic (PV) system is greatly influenced by the initial investment cost for system installation. Also, electricity generation by PV system is highly important. The profits competitiveness of PV system will be maximized through intelligent operation and maintenance (O&M). Here, we developed a microconverter which can maximize electricity generation from PV modules by tracking the maximum power point of PV modules, and help efficient O&M. Also, the microconverter mitigates current mismatch caused by shading, hence maximize power generation. The microconverters were installed PV modules and demonstrated through the field tests. Power outputs such as voltage, string current were measured with variuos weather environments and partial shadings. We found that PV modules with the microconvertors shows 12.05% higher power generation compared to the reference PV modules.
Journal of the Korean Institute of Intelligent Systems
/
v.23
no.2
/
pp.107-112
/
2013
In the paper, velocity controller of switching module and temperature controller for the high-voltage static var compensator are proposed. Because of the continuous increase in demand for electric power, transmission and distribution facilities of power plant are required. There is a bottleneck problem of transportation routes according to new construction and expansion of power transmission facilities. Therefore there are researches to maximize the utilization of existing facilities and to increase transmission capacity without new construction. The previous static var compensator detects voltage of input circuit of power, switches the SCR directly and generates switching noise. The proposed method increases switching velocity and decreases noise using switching control based on the voltage between both sides of SCR. Also the proposed method enhance the stability using realtime temperature control for heating of the system from increase of switching velocity. We experiment the velocity and temperature control of the proposed high-voltage static var compensator in the real environment and verify the performance of the proposed system by applying in the real field.
Journal of the Institute of Electronics Engineers of Korea SD
/
v.38
no.1
/
pp.13-22
/
2001
This paper presents three dimensional structure of RF packages and the improvement effect of its electrical characteristics when implementing RF transceivers. We divided RF modules into several subunits following each subunit function based on the partitioning algorithm which suggests a method of three dimension stacking interconnection, PAA(pad area array) interconnection and stacking of three dimensional RF package structures. 224MHz ITS(Intelligent Transportation System) RF module subdivided into subunits of functional blocks of a receiver(RX), a transmitter(TX), a phase locked loop(PLL) and power(PWR) unit, simultaneously meeting the requirements of impedance characteristic and system stability. Each subfunctional unit has its own frequency region of 224MHz, 21.4MHz, and 450KHz~DC. The signal gain of receiver and transmitter unit showed 18.9㏈, 23.9㏈. PLL and PWR modules also provided stable phase locking, constant voltages which agree with design specifications and maximize their characteristics. The RF module of three dimension stacking structure showed $48cm^3$, 76.9% reduction in volume and 4.8cm, 28.4% in net length, 41.8$^{\circ}C$, 37% in maximum operating temperature, respectively. We have found that three dimensional PAA package structure is able to produce high speed, high density, low power characteristics and to improve its functional characteristics by subdividing RF modules according to the subunit function and the operating frequency, and the features of physical volume, electrical characteristics, and thermal conditions compared to two dimensional RF circuit modules.
Kim, Man-Ho;Park, Jee-Hun;Lee, Suk;Lee, Kyung-Chang
Journal of Institute of Control, Robotics and Systems
/
v.17
no.2
/
pp.176-182
/
2011
Industrial network, often referred to as fieldbus, becomes an indispensable component for intelligent manufacturing systems. Thus, in order to satisfy the real-time requirements of field devices such as sensors, actuators, and controllers, numerous fieldbus protocols have been developed. But, the application of fieldbus has been limited due to the high cost of hardware and the difficulty in interfacing with multi-vendor products. As an alternative to fieldbus, the Ethernet (IEEE 802.3) technology is being adapted to the industrial environment. However, the crucial technical obstacle of Ethernet is its non-deterministic behavior that cannot satisfy the real-time requirements. Recently, the EtherCAT protocol becomes a very promising alternative for real-time industrial application due to the elimination of uncertainties in Ethernet. This paper focuses on the implementation of the IEC 61800 based real-time EtherCAT network for multi-axis smart driver. To demonstrate the feasibility of the implemented EtherCAT slave module, its synchronization performance is evaluated on the experimental EtherCAT testbed with a single axis smart driver.
요 몇 해 사이에 고내압$\cdot$대용량 파워디바이스에서는 아주 새로운 진전이 일어나고 있다. 파워일렉트로닉스 장치의 소형화$\cdot$고효율화 및 제어의 고속화 등의 요구에 응할 수 있는 차세대의 새로운 소자가 출현하여 그 제품화가 비약적으로 진전되고 있는 것이다. 새로운 파워디바이스의 대표적인 것으로는 다음의 3가지를 들 수 있다. $\cdot$HVIGBT(High Voltage Insulated Gate Bipolar Transistor Module)$\cdot$HVIPM(High Voltage Intelligent Power Module)$\cdot$GCT(Gate Commutated Turn-off)사이리스터 이들의 파워디바이스를 종래의 GTO(Gate Turn-off) 사이리스터와 비교해 보면 다음과 같은 특징이 있다.(1)GTO 사이리스터가 필요로 했던 스나버회로가 없어도(Snabber-less)턴오프가 가능하며, di/dt 억제용 아노드리액터의 생략 또는 저감이 가능하기 때문에 반도체 부녀회로의 소형화를 기할 수 있다. (2)게이트파워와 전체손실(소자 및 주변회로를 포함)의 저감으로 에너지 절약을 도모할 수 있다. (3)스위칭주파수를 2$\~$3kHz 정도까지 높일 수 있다. 이런 장점 때문에 다음과 같은 용도에의 적용이 기대되고 있다. (1)신간선, 지하철 등의 전철 응용 (2)액티브필터, SVG(무효전력발생장치), SVC(무효전력보상장치) BTB, 가변속 양수발전 스위치 등의 전력응용 (3) 철강압연이나 제지공장용 등의 대용량공업용 컨버터$\cdot$인버터 응용 HVIGBT와 HVIPM은 전철분야에서 신간선의 추진용 컨버터$\cdot$인버터장치와 보조전원장치, 그리고 지하철의 추진용 인버터 장치나 보조전원장치 등에 채용되고 GCT 사이리스터는 전력용 주파수변환기 등에 실용화되고 있다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.