• 제목/요약/키워드: Integrated display processing module

검색결과 11건 처리시간 0.022초

가상현실과 모바일 환경 기반의 통합 에이전트 제어 시스템 (An Integrated Agent Control System Based on Virtual Reality and Mobile Environment)

  • 박준홍;변광호;석정호;안현식
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2002년도 추계학술발표논문집 (상)
    • /
    • pp.27-30
    • /
    • 2002
  • Recently, there are lots of concerning on the control of multi-agent control system and mixed reality integrating real and virtual environments. In this paper, an integrated agent control system based on mixed reality and mobile environment is proposed. The system consists of a manager, agents, a mapping module, a geographic information module, a WAP server, and a mobile manager. The manager has Hybrid Device Manager(HDM) working for revising images and position data of the agents to display that at the 3D virtual and mobile environments respectively. Especially, the images of the agent is translated to LBM format and displayed on the mobile phone, and the current position of the agent is displayed on the display screen, so that a user are able to control the agent when he is moving. Experimental results shows the proposed system lets us control the agents conveniently at a computer and a mobile phone.

  • PDF

Indoor positioning system for naval ship personnel using beacon

  • Kim, Jong-Hwa;Kim, Joo-Yong
    • 한국컴퓨터정보학회논문지
    • /
    • 제24권11호
    • /
    • pp.135-142
    • /
    • 2019
  • 본 논문에서는 블루투스 기반의 비콘을 활용하여 해군 함정의 인력들의 위치를 한눈에 파악할 수 있는 시스템을 제안한다. 이 논문에서 제안된 시스템은, 근거리 무선통신장치인 비콘을 수신할 수 있는 비콘 수신기를 선실마다 설치하고 인력들이 소지한 비콘에서 발신하는 정보를 수신한다. 수신된 정보는 처리 서버로 송신하고 처리서버에서는 객실별 인원 정보를 통합 처리하여 전시모듈로 송신한다. 전시모듈에서는 각 객실별로 위치하고 있는 인력정보를 전시한다. 설계한 시스템을 이용하여 모의시험을 실시한 결과 통합 처리된 객실별 인력 위치정보가 전시모듈로 전달되어 전시 되는 것을 확인하였다. 함정 내에서 구두로 인력 위치가 보고되는 기존 상황과 달리 실시간으로, 신속하게 인력 위치를 확인할 수 있는 본 시스템은 비전투 상황에서의 인원관리, 전투상황에서의 신속한 전투배치에 도움을 준다. 이는 전투력 향상에 큰 기여를 할 것으로 기대된다.

FTP와 JSON을 활용한 대용량 미디어의 항공장비용 데이터 로드 프로세스 (Data Load Process of large-sized media for avionics using FTP and JSON)

  • 최지환;최낙민;신재권
    • 한국항행학회논문지
    • /
    • 제27권5호
    • /
    • pp.610-620
    • /
    • 2023
  • 4차 산업 혁명에 기반한 기술발전 및 항공사들의 고객 유치를 위한 경쟁으로 인해 항공기 인테리어 시장에 대한 관심이 증가하고 있으며, 그 일환으로 국내에서는 FAA Part.25급 민항기를 대상으로 한 CDS (Cabin Display System)이 개발되고 있다. CDS는 IDPM (Integrated Display Processing Module)로 제어되는 대형 Flexible 및 투명 OLED (Organic Light Emitting Diodes)를 활용하여 승객들에게 다양한 멀티미디어 서비스를 제공하는 시스템으로 고품질의 서비스 제공을 위해 대용량의 미디어 콘텐츠 활용이 필수적으로 요구된다. 본 논문에서는 대용량 파일들의 효율적인 Data Load Process를 수행하기 위한 새로운 방안을 제시하고 그 구현 및 성능을 다룬다. 본 연구 결과는 기존 ARINC-615A 대비 Data Load Process 개발 비용의 절감과 더불어 신뢰성 높은 대용량 파일 전송이 필요한 항공 장비의 Data Load Process 개발에 대체 적용이 가능할 것으로 기대된다.

자동 표면 결함검사 시스템에서 Retro 광학계를 이용한 3D 깊이정보 측정방법 (Linear System Depth Detection using Retro Reflector for Automatic Vision Inspection System)

  • 주영복
    • 반도체디스플레이기술학회지
    • /
    • 제21권4호
    • /
    • pp.77-80
    • /
    • 2022
  • Automatic Vision Inspection (AVI) systems automatically detect defect features and measure their sizes via camera vision. It has been populated because of the accuracy and consistency in terms of QC (Quality Control) of inspection processes. Also, it is important to predict the performance of an AVI to meet customer's specification in advance. AVI are usually suffered from false negative and positives. It can be overcome by providing extra information such as 3D depth information. Stereo vision processing has been popular for depth extraction of the 3D images from 2D images. However, stereo vision methods usually take long time to process. In this paper, retro optical system using reflectors is proposed and experimented to overcome the problem. The optical system extracts the depth without special SW processes. The vision sensor and optical components such as illumination and depth detecting module are integrated as a unit. The depth information can be extracted on real-time basis and utilized and can improve the performance of an AVI system.

Full Color LED 디스플레이장치와 휘도 개선과 호환성을 갖는 통합인터페이스 제어장치 구현 (Implemented of Integrated Interface Control Unit with Compatible and Improve Brightness of Existing Full Color LED Display System)

  • 이주연
    • 융합정보논문지
    • /
    • 제11권12호
    • /
    • pp.90-96
    • /
    • 2021
  • 본 논문에서는 밝기제어장치 및 색상제어장치 그리고 기존의 제어장치와의 호환성을 갖는 통합 인터페이스 제어장치 설계하고 제작하여 구현하였다. 구현 방법으로는 데이터 전송방식은 DVI/HDMI 전송방식의 규격을 적용하였으며 적용한 IC는 Sil1169 IC를 사용하였다. 밝기제어는 AT89C2051을 사용하여 8단계의 밝기조절 기능을 갖도록 프로그래밍하였다. 또한 영상 및 디밍 데이터 처리를 위하여 EPM240T100C5 IC를 사용하여 제작하였다. 그 결과로 기존에 제작하여 사용되어지고 있는 DVI/HDMI 전송방식을 적용한 제어장치와 호환이 가능하고, 주변 밝기에 따라 선명하고 고품질의 Full HD급 영상을 LED 디스플레이 장치에 통하여 재생할 수 있는 결과를 얻었다.

캐빈 디스플레이 시스템을 위한 원격 제어 소프트웨어의 설계 및 구현 (Design and Implementation of Remote Control Software for Cabin Display System)

  • 신재권;최지환;최낙민;김정열;김준형
    • 한국항행학회논문지
    • /
    • 제28권5호
    • /
    • pp.698-705
    • /
    • 2024
  • 최근 항공 산업 경쟁이 심화함에 따라 항공기 인테리어 산업도 첨단 IT (information technology) 요소를 접목하는 등 빠르게 발전하고 있다. 국내에서는 보잉사와 협력하여 항공기용 디스플레이 시스템인 CDS (cabin display system)를 개발 중이며, 본 논문에서는 CDS의 원격 제어 소프트웨어인 CDS RCS (cabin display system remote control software)의 설계 및 구현의 내용을 다룬다. CDS RCS 는 ARINC-615A 표준을 응용하여 자체 개발한 항공기용 데이터로드 프로세스와, MQTT (message queuing telemetry transport) 프로토콜을 적용하여 개발하였다. 또한 CDS RCS는 기존의 CDS 제어 소프트웨어와 달리 MQTT client 형태로 설계되어 다른 MQTT client 장치들과 독립적으로 운용할 수 있다는 장점이 있으며, 개인 단말기에 쉽게 설치할 수 있는 안드로이드 기반으로 개발되어 승무원들의 편의성이 크게 향상될 것으로 기대된다.

세상에서 가장 얇은 그래핀 발광 소자 (The World's Thinnest Graphene Light Source)

  • 김영덕
    • 진공이야기
    • /
    • 제4권3호
    • /
    • pp.16-20
    • /
    • 2017
  • Graphene has emerged as a promising material for optoelectronic applications including as ultrafast and broadband photodetector, optical modulator, and nonlinear photonic devices. Graphene based devices have shown the feasibility of ultrafast signal processing for required for photonic integrated circuits. However, on-chip monolithic nanoscale light source has remained challenges. Graphene's high current density, thermal stability, low heat capacity and non-equilibrium of electron and lattice temperature properties suggest that graphene as promising thermal light source. Early efforts showed infrared thermal radiation from substrate supported graphene device, with temperature limited due to significant cooling to substrate. The recent demonstration of bright visible light emission from suspended graphene achieve temperature up to ~3000 K and increase efficiency by reducing the heat dissipation and electron scattering. The world's thinnest graphene light source provides a promising path for on-chip light source for optical communication and next-generation display module.

어구 식별 및 관리를 위한 통합 관제 시스템 개발 (A Development of Integrated Monitoring and Control System for Identification and Management of Fishing Gears)

  • 황훈규;김배성;우상민;우윤태;김남수;남경태;황지중;이영근
    • 한국정보통신학회논문지
    • /
    • 제22권9호
    • /
    • pp.1228-1236
    • /
    • 2018
  • 최근 폐어구로 인한 해양 환경오염이 심각하게 대두되고 있으며, ICT 기술의 접목을 통해 어구를 체계적으로 관리함으로서 이러한 문제를 해결하기 위한 방법이 요구되고 있다. 기존 어구 식별 및 관리를 위한 시스템들은 소유주의 선택에 의해 사용하던 실정으로 보다 통합적이고 국가적인 관제 체계가 필요하다. 이를 위해 본 논문에서는 어구에 자동식별 부이를 부착하고, 사물인터넷망을 활용하여 어구의 위치 및 상태정보를 어선, 관리 선박, 육상 관제센터 등으로 전송하여 효과적인 모니터링 및 관리가 가능하도록 하는 체계를 소개하며, 특히 통합 관제 시스템의 개발 및 기능 성능 검증에 관한 내용을 중점적으로 다룬다. 개발하는 시스템은 효율적인 어구 관제를 위하여 전자해도를 기반으로 어구 위치, 상태정보, 유실알람 등을 표시해주는 기능을 한다. 또한, 가상 어구 자동식별 부이 생성 모듈을 개발하고, 이를 기반으로 개발한 시스템의 처리 및 시각화 성능을 테스트하는 것에 관한 내용을 다룬다.

사용자 중심적 GIS 인터페이스를 이용한 시계열적 원격탐사 영상의 변화탐지 기법의 개발 (Development of Change Detection Technique Using Time Seriate Remotely Sensed Satellite Images with User Friendly GIS Interface)

  • 양인태;한성만;윤희천;김흥규
    • 한국측량학회지
    • /
    • 제22권2호
    • /
    • pp.151-159
    • /
    • 2004
  • 현대사회는 인간 활동 범위의 다양함과 영역확대에 따른 급속한 도시화로 자연환경의 파괴와 천연자원의 고갈이라는 문제에 봉착되었다. 이러한 상황에서 국토의 효율적인 관리와 이용 계획을 위해서 광범위한 토지이용에 따른 변화를 신속하고 정화하게 탐지할 수 있는 변화탐지기술이 요구되었다. 본 연구에서는 원격탐사 영상의 변화탐지를 실시하기 위해 지형공간정보 시스템이 갖고 있는 공간분석기법을 적용하여 새로운 변화탐지 알고리즘과 검색, 질의 및 분석 등의 기능을 수행할 수 있는 소프트웨어를 제작하였다. 이 소프트웨어는 그래픽 사용자 인터페이스를 기본으로 하여 파일변환, 그리드연산, 통계계산, 디스플레이, 검색 등의 기능이 포함되어 있다. 본 연구의 수행 결과 다중시기의 위성영상에 대한 변화탐지를 동시에 수행할 수 있었으며, 네 시기에 대한 통합된 변화영상을 제작할 수 있었다. 또한 사용자가 토지피복에 대한 년도별 변천 내용을 질의하고 검색할 수 있게 함으로써 특정지역의 토지피복에 대한 변천 정보를 획득할 수 있었다. 마지막으로 변화탐지 수행을 위한 개개 응용프로그램의 각 모듈을 윈도우 기반의 Visual Basic으로 통합함으로써 사용자 편의 제공과 자동화를 가져올 수 있었다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF