• Title/Summary/Keyword: Integrated Floor

Search Result 134, Processing Time 0.027 seconds

Floor Impact Noise Level for Concrete Slab Integrated with Floor Finishing Layers (콘크리트 슬래브와 바닥 상부구조가 일체된 바닥구조의 바닥충격음)

  • Mun, Dae Ho;Oh, Yang Ki;Jeong, Gab Cheol;Park, Hong Gun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.2
    • /
    • pp.130-140
    • /
    • 2016
  • Floating floor is most commonly used at apartment houses in Korea for thermal insulation and reducing impact noise. But it in proven that the floating floor is not effective for reducing the floor impact noise in low frequency range. In most cases, impact sound pressure level under 63 Hz frequency band were actually increased by the resonance of resilient material, lightweight concrete and the finishing mortar installed on it. In this paper, an integrated floor system consist of 70 mm light weight concrete and 40 mm finishing mortar successively installed on the concrete slab was suggested to avoid the resonance. Integrated floor system increases total flexural stiffness and mass per unit area. The natural frequencies of first and second vibration mode were increased and acceleration response and floor impact sound level was decreased in all measurement range.

Development of a Shop Floor-Centered Integrated Design/Manufacturing Information System for the Production of Aerospace Structure Parts (항공기 기체 부품 생산을 위한 생산 현장 중심의 설계 생산 통합 / 정보 시스템 개발)

  • 한관희;최운집;박찬우;이상한
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1007-1012
    • /
    • 2004
  • To increase the productivity and efficiency of an enterprise, all relevant product information should be provided to shop floor workers timely and in a unified form because shop floor workers are final consumers of most accumulated information generated from various departments of an enterprise. but, most existing enterprise information systems have an emphasis upon providing design/manufacturing information to office workers. Proposed in this study is a development of integrated design/manufacturing information system focused system, the function required for shop floor activities. For developing integrated information system, the functional required for shop floor are identified and analyzed. Based on the extracted functional requirements, object-oriented system design and implementation is conducted. By using this system, shop floor workers can refer to all relevant information necessary to their work easily and in a integrated form.

  • PDF

An Experimental Study for Evaluating Performance of Radiant Floor Cooling System Integrated with Dehumidification (제습기능이 통합된 바닥복사 냉방시스템의 용 가능성에 관한 실험적 연구)

  • 이상엽;황석호;김가현;이승복
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.2
    • /
    • pp.143-152
    • /
    • 2002
  • It is critical for radiant floor cooling system using Ondol to cause condensation on a floor surface. To solve this problem, a radiant floor cooling system integrated with dehumidification was proposed and evaluated in terms of its applicability and prevention of condensation. Therresults show that the proposed system of radiant floor cooling integrated with dehumidification properly maintained the indoor setpoint temperatures and prevented the condensation on a floor surface. To achieve more stable indoor temperatures and humidity control, a further study for the operation of dehumidification panel will be needed.

The Development of a Shop Floor-Centered Information System for the Integration of Design and Manufacturing Data (생산 현장 중심의 설계/생산 통합 정보 시스템 개발)

  • Han K. H.;Park C. W.;Oak J. S.;Kim K. S.
    • Korean Journal of Computational Design and Engineering
    • /
    • v.10 no.4
    • /
    • pp.237-243
    • /
    • 2005
  • To increase the productivity and efficiency of an enterprise, all relevant product information should be provided to shop floor workers timely and in a unified form because shop floor workers are final consumers of most accumulated information generated from various departments of an enterprise. But, most existing enterprise information systems have an emphasis upon providing design/manufacturing information to office workers. Proposed in this study is the development of integrated design/manufacturing information system focused on providing cohesive information required to shop floor activities. For developing integrated information system, the functional requirements at the shop floor are identified and analyzed. Based on the extracted functional requirements, object-oriented system design and implementation is conducted. By using this system, shop floor workers can use all relevant information required to their daily operation in a integrated and unified form.

A Study on the System Integration and Control Method of Radiant floor Cooling in Apartment Buildings (공동주택에서 바닥복사냉방의 시스템 구성과 제어 방안에 관한 연구)

  • 조영흠;석호태;김광우;여명석
    • Journal of the Korean housing association
    • /
    • v.15 no.2
    • /
    • pp.107-115
    • /
    • 2004
  • The objective of this study is to show the system Integrations and control method for operation of the Radiant Floor Cooling. The systems for radiant floor cooling system consist of only using the radiant floor cooling and the radiant floor cooling integrated with a dehumidification system. And the study is suggested control method with composed radiant floor cooling system through simulations. Radiant floor cooling systems compose of four main parts: an existing radiant heating panel, manifold, cooling source and controller, and sensors. If dehumidifying or supplementary cooling is needed, additional equipments such as PAC and AHU are needed. Simulation results show that control method only using radiant floor cooling system can prevent condensation and set room air temperature with the exception of hot and humid periods and control method using the radiant floor cooling integrated with a dehumidification system is comfort thermal environments and can reduce the cooling load quickly, moreover, show comfort control method to meet various cooling operation situations.

Hybrid Shop Floor Control System for Computer Integrated Manufacturing (CIM)

  • Park, Kyung-Hyun;Lee, Seok-Hee
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.544-554
    • /
    • 2001
  • A shop floor can be considered as an important level to develop Computer Integrated Manufacturing system (CIMs). However, a shop floor is a dynamic environment where unexpected events continuously occur, and impose changes to the planned activities. To deal with this problem, a shop floor should adopt an appropriate control system that is responsible for the coordination and control of the manufacturing physical flow and information flow. In this paper, a hybrid control system is described with a shop floor activity methodology called Multi-Layered Task Initiation Diagram (MTD). The architecture of the control model contains three levels: i.e., he shop floor controller (SFC), the intelligent agent controller (IAC) and the equipment controller (EC). The methodology behind the development of the control system is an intelligent multi-agent paradigm that enables the shop floor control system to be an independent, an autonomous, and distributed system, and to achieve an adaptability to change of the manufacturing environment.

  • PDF

Lowering Error Floor of LDPC Codes Using an Improved Parallel WBF Algorithm

  • Ma, Kexiang;Li, Yongzhao;Zhu, Caizhi;Zhang, Hailin;Zhang, Yuming
    • ETRI Journal
    • /
    • v.36 no.1
    • /
    • pp.171-174
    • /
    • 2014
  • In weighted bit-flipping-based algorithms for low-density parity-check (LDPC) codes, due to the existence of overconfident incorrectly received bits, the metric values of the corresponding bits will always be wrong in the decoding process. Since these bits cannot be flipped, decoding failure results. To solve this problem, an improved parallel weighted bit flipping algorithm is proposed. Specifically, a reliability-saturation strategy is adopted to increase the flipping probability of the overconfident incorrectly received bits. Simulation results show that the error floor of LDPC codes is greatly lowered.

Formal integration of process planning and shop floor control with petri nets

  • Lee, Kyung-Huy
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1996.04a
    • /
    • pp.619-622
    • /
    • 1996
  • This paper presents the formal integration of process planning and shop floor control with Petri net formalism. Formal integration means that both planning and control problems can be modeled, interfaced, and transformed with the Petri net formalism. This integrated framework provides a systematic approach for rapidly developing a formal shop floor controller from process planning with respect to shop floor configuration.

  • PDF

A Comparative Study on the Spatial Layout Characteristics of Modern Apartment Floor Plan and 'Standard Korea Traditional-Houses Floor Plan' (현대 아파트 평면도와 한옥표준평면도의 공간배치 특성 비교 연구)

  • Hwang, Yong-Woon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.271-278
    • /
    • 2019
  • This study compares the space depth and layout of a modern apartment floor plan (MAFP) and the standard floor plan of traditional Korean houses (STKHs), which has preserved the traditional beauty of Korea. Space Syntax was applied to compare the MAFP and STKH. The space within MAFP was more divided into many spaces than the STKH. In both types of floor plans, the living room space had the highest degree of integration and was used for central functions in the each floor plan. The STKH and the space in the MAFP have more segregated space than integrated space. In the STKH, the master bedroom and other rooms were found to be segregated space. However, the master bedroom of the MAFP was highly integrated space. The function of the thet maru has been greatly reduced in the STKH, and the numaru was classified as a highly segregated space. The evacuation space was the most segregated space in the MAFP. The STKH has been adapted and changed according to the trends of the times, and the MAFP reflects our traditional living habits.

A Study on the Architectural Planning for Integrated Nursing Care Service in Ward of Public Hospital - Focused on the Regional Public Hospital in Korea - (간호·간병통합서비스를 위한 국내 공공병원 병동부에 대한 건축 계획적 연구 - 국내 지역거점 지방의료원을 중심으로 -)

  • Han, Suk-Bum;Park, Jae-Seung
    • Korean Institute of Interior Design Journal
    • /
    • v.26 no.3
    • /
    • pp.121-129
    • /
    • 2017
  • The study is to identify the status of the ward of public hospital for integrated nursing care service. Integrated nursing service has expanded nationwide from 2016 but 10 out of 34 public hospitals are currently unable to operate as nurses due to the shortage. Analyze each floor plan and space program of ward and provide the basic data for the construction of the architecture plans for Integrated nursing care service. For this study, selecting 14 wards of public hospital in Korea and then analyzes space organization, distance from NS to bedroom and NS to core(Elevator) and spatial hierarchy of them. Among the 14 public hospitals, there are 7 types of double-loaded corridor, 4 types of double corridor and 3 types of single corridor. If NS is placed centrally, the control of the outsider and the patient's control would be efficient, but most of NS are lean on one side of floor. the placement of NS should be independent of individual arrangements, but it should be smooth alignment with patient spaces, staff spaces, and public spaces. This study could serve as basic research for the architectural plan for future integrated nursing care in ward of public hospital.