• Title/Summary/Keyword: Integrated Demonstration

Search Result 99, Processing Time 0.041 seconds

Demonstration Study of 10kW Poly Metal Panel integrated PV Module (10kW급 지붕재용 태양전지모듈 실증연구)

  • Yi, So-Mi;Noh, Ji-Hee;Joo, Man-Sic
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.246-249
    • /
    • 2007
  • The application of photovoltaics into building as integrated building components has been paid more attention worldwide. Photovoltaics or solar electric modules are sol id state devices, directly converting solar radiation into electricity; the process does not require fuel and any moving parts, and produce no pollutants. And the prefab building method is very effective because the pre- manufactured building components is simply assembled to making up buildings in the construction fields especially the sandwich panel. So, this paper describes a design and performance test of the 10kW poly metal pv module(pmpp) system. It is concluded that the prediction of BIPV system's performance should be based on the more accurate PV module installation.

  • PDF

Evaluation of Electricity Generation According to Installation Type of Photovoltaic System in Residential Buildings (주거용 건물 태양광발전시스템의 설치유형에 따른 발전성능 평가)

  • Kim, Deok-Sung;Kim, Beob-Jeon;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.2
    • /
    • pp.35-45
    • /
    • 2017
  • The types of installation of the photovoltaic system applied to domestic residential buildings are classified as follows: Mounted modules with air circulation, semi-integrated modules with air duct behind, integrated modules with fully insulated back. In order to study generation characteristics of PV system, we verified the validity of interpretation program based on long-term measurement data of demonstration house installed in BAPV form and also analyzed the generation characteristics and performance of each installation type. The results are as follows. First, the RMSE of amount of generation and simulation according to annual daily insolation of demonstration system located in Daejeon was 0.98kWh and the range of relative error of monthly power generation was -5.8 to 3.1. Second, the average annual PR of mounted modules was 82%, semi-integrated modules 76.1% and integrated modules 71.9%. This differences were attributed to temperature loss. Third, the range of operating temperature of annual hourly photovoltaic modules was -6.5 to $61.0^{\circ}C$ for mounted modules, $-6.0{\sim}73.9^{\circ}C$ for semi-integrated modules and -5.5 to $88.9^{\circ}C$ for integrated modules. The temperature loss of each installation type was -14.0 to 16.1%, -13.8 to 21.9%, and -13.6 to 28.5%, respectively.

A study on the performance of various BIPV modules applied in a real building demonstration (BIPV시스템의 건물적용 실증에 대한 구성요소별 발전성능 분석)

  • Lee, Sang-Moon;Huh, Jung-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.2
    • /
    • pp.53-63
    • /
    • 2016
  • Building Integrated Photovoltaic (BIPV) is one of the best ways to generate electric power using the solar energy, which is clean and inexhaustible energy resources. The most of BIPV modules have the form of GtoG (Glass to Glass) photovoltaic in building applications. Degradation leading to failure in photovoltaic modules is very important factor in BIPV modules. This paper analyzed the performance of various BIPV modules through outdoor exposure tests. Performance of three BIPV modules(c-Si type, a-Si type and DSSC type) with three installation angles influenced by sun light, outdoor temperature, and wind velocity was monitored and analyzed. As a result, c-Si type BIPV module outperforms other BIPV modules(a-Si type). In terms of power efficiency of the module, the installed angle of $45^{\circ}$ is better than others(90 degree, 0 degree). In addition, more realistic data of various BIPV system performance could be available through the field test and integrated building test. In this study, relationship of the BIPV system is identified module's installation angle, power generation, architectural performance, etc.

Development of Korea eCall System and Effects Analysis through Integrated Demonstration (한국형 eCall 시스템 개발 및 통합실증을 통한 기대효과 분석)

  • Sangheon Kim;Youngsung Cho;Sunwoo Kim
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.23 no.1
    • /
    • pp.61-81
    • /
    • 2024
  • eCall system assists traffic accident victims by connecting emergency rescue institutions with accurate accident information, helping them to identify the on-site situation in the event of a traffic accident. The purpose of this paper is to develop a Korean eCall system that reflects the requirements of domestic emergency rescue institutions and to analyze the expected effects through an integrated demonstration. The results of an integrated demonstration indicated that the communication success rate between the eCall IVS and the call center was 99.25%, and the average location information error was 1.2 m. In particular, it has been confirmed that the average location information error is less than 21.6 meters, as assessed by the Korea Communications Commission when evaluating the accuracy of domestic emergency rescue location information. When the eCall system was introduced, it was confirmed that the time from traffic accidents to hospital arrival could be shortened by 3 m 38 s for highways and 1 m 22 s for general roads. By it to traffic deaths from 2005 to 2022, it was analyzed that the number of fatalities decreased by 82,662, resulting in a reduction of approximately social costs.

파이로 기술추적시스템 개발 현황

  • Kim, Seong-Gi
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2010.10a
    • /
    • pp.315-316
    • /
    • 2010
  • 본 연구는 파이로일관공정시험시설인 PRIDE (Py-Roprocess Integrated DEmonstration facility)의 최상위 요구사항부터 파이로 세부공정의 설계요건까지 논리적이며 체계적인 연관성을 제시할 수 있는 파이로 기술추적시스템 개발현황을 기술하였다. 이러한 기술추적기능을 도출하기 위하여 시스템 엔지니어링 도구인 Cradle 데이터베이스를 이용하였다.

  • PDF

Non-Toxic Post Boost Stage Demonstration

  • Fukuchi, Apollo B.;Ooya, Koji;Harada, Osamu;Makino, Takashi;Matsuda, Seiji;Akiyama, Masao
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.437-441
    • /
    • 2008
  • A non-toxic Post Boost Stage(PBS) with LOX/Ethanol engine was successfully demonstrated at the Tomioka Facility of IHI Aerospace. IHI Aerospace has researched and developed the nontoxic propulsion systems and the LOX/Ethanol is one of the most attractive non-toxic bipropellant candidates. ${\rho}ISP$ of LOX/Ethanol is higher than ${\rho}ISP$ of the other non-toxic bipropellants as LOX/HC or $LOX/LH_2$. The authors studied the combustion characteristics of LOX/Ethanol propellant with the engine designed for LOX/LNG propellant. Also the injector with a built-in igniter was designed and examined its feasibility, ignition and combustion characteristics. We have demonstrated Post Boost Stage with future LOX/Ethanol engines. This propulsion system is targeted for expandable vehicle upper stage to accelerate delta-V to reach the required orbit. PBS Demonstration Model is designed as a test stand to evaluate feed system for integrated propulsion system and also to demonstrate Integrated Vehicle Health Management(IVHM) technique using local valve control and also valve behavior-monitoring capability.

  • PDF

High Plasticity of the Gut Microbiome and Muscle Metabolome of Chinese Mitten Crab (Eriocheir sinensis) in Diverse Environments

  • Chen, Xiaowen;Chen, Haihong;Liu, Qinghua;Ni, Kangda;Ding, Rui;Wang, Jun;Wang, Chenghui
    • Journal of Microbiology and Biotechnology
    • /
    • v.31 no.2
    • /
    • pp.240-249
    • /
    • 2021
  • Phenotypic plasticity is a rapid response mechanism that enables organisms to acclimate and survive in changing environments. The Chinese mitten crab (Eriocheir sinensis) survives and thrives in different and even introduced habitats, thereby indicating its high phenotypic plasticity. However, the underpinnings of the high plasticity of E. sinensis have not been comprehensively investigated. In this study, we conducted an integrated gut microbiome and muscle metabolome analysis on E. sinensis collected from three different environments, namely, an artificial pond, Yangcheng Lake, and Yangtze River, to uncover the mechanism of its high phenotypic plasticity. Our study presents three divergent gut microbiotas and muscle metabolic profiles that corresponded to the three environments. The composition and diversity of the core gut microbiota (Proteobacteria, Bacteroidetes, Tenericutes, and Firmicutes) varied among the different environments while the metabolites associated with amino acids, fatty acids, and terpene compounds displayed significantly different concentration levels. The results revealed that the gut microbiome community and muscle metabolome were significantly affected by the habitat environments. Our findings indicate the high phenotypic plasticity in terms of gut microbiome and muscle metabolome of E. sinensis when it faces environmental changes, which would also facilitate its acclimation and adaptation to diverse and even introduced environments.

Empirical evaluation for design parameters and operating characteristics of the integrated sedimentation and dissolved air flotation (SeDAF) process at the pilot-scale plant (파일럿 플랜트 규모에서 일체형 침전부상공정 (SeDAF)의 설계인자 및 운전특성에 대한 실증적 평가)

  • Jang, Yeoju;Jung, Jinhong;Lim, Hyunman;Kim, Weonjae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.1
    • /
    • pp.1-14
    • /
    • 2021
  • Eutrophication and algal blooms can lead to increase of taste and odor compounds and health problems by cyanobacterial toxins. To cope with these eco-social issues, Ministry of Environment in Korea has been reinforcing the effluent standards of wastewater treatment facilities. As a result, various advanced phosphorus removal processes have been adopted in each wastewater treatment plant nation-widely. However, a lot of existing advanced wastewater treatment processes have been facing the problems of expensive cost in operation and excessive sludge production caused by high dosage of coagulant. In this study, the sedimentation and dissolved air flotation (SeDAF) process integrated with sedimentation and flotation has been developed for enhanced phosphorus removal in wastewater treatment facilities. Design and operating parameters of the SeDAF process with the capacity of 100 ㎥/d were determined, and a demonstration plant has been installed and operated at I wastewater treatment facility (located in Gyeonggi-do) for the verification of field applicability. Several empirical evaluations for the SeDAF process were performed at demonstration-plant scale, and the results showed clearly that T-P and turbidity values of treated water were to satisfy the highest effluent standards below 0.2 mg/L and 2.0 NTU stably for all of operation cases.