• 제목/요약/키워드: Integral image

검색결과 332건 처리시간 0.024초

Identification and Correction of Microlens-array Error in an Integral-imaging-microscopy System

  • Imtiaz, Shariar Md;Kwon, Ki-Chul;Alam, Md. Shahinur;Hossain, Md. Biddut;Changsup, Nam;Kim, Nam
    • Current Optics and Photonics
    • /
    • 제5권5호
    • /
    • pp.524-531
    • /
    • 2021
  • In an integral-imaging microscopy (IIM) system, a microlens array (MLA) is the primary optical element; however, surface errors impede the resolution of a raw image's details. Calibration is a major concern with regard to incorrect projection of the light rays. A ray-tracing-based calibration method for an IIM camera is proposed, to address four errors: MLA decentering, rotational, translational, and subimage-scaling errors. All of these parameters are evaluated using the reference image obtained from the ray-traced white image. The areas and center points of the microlens are estimated using an "8-connected" and a "center-of-gravity" method respectively. The proposed approach significantly improves the rectified-image quality and nonlinear image brightness for an IIM system. Numerical and optical experiments on multiple real objects demonstrate the robustness and effectiveness of our proposed method, which achieves on average a 35% improvement in brightness for an IIM raw image.

거리에 따른 집적 영상 복원을 지원하는 에뮬레이터의 구현 (Implementation of an Emulator for the Integrated Image Reconstruction according to Distance)

  • 장하은;이은지;이연주;임순범
    • 한국멀티미디어학회논문지
    • /
    • 제19권3호
    • /
    • pp.548-556
    • /
    • 2016
  • Integral imaging is an auto-stereoscopic display method that can produce 3D image of a finite viewing window through an array of micro elemental lenses. Integral imaging requires the pickup part of each elemental images acquisition and display part of reconstruction of the images. The successful reconstructed image depends on various parameters such as distance between lens arrays and display device, focal length of lenses, and a number of the array. In this paper, we present reconstruction emulator for display of Integral imaging in order to adjust parameters for 3D contents reconstruction and to observe the result from different configuration. Especially, we provide the user interface for the emulator to control the distance easily. We have confirmed through various experiments that the emulator adjusted the distance and could check error in the process of creating elemental images.

집적 영상 시스템을 위한 향상된 이미지 매핑 방법 (Enhanced Image Mapping Method for Computer-Generated Integral Imaging System)

  • 이빛나라;조용주;박경신;민성욱
    • 정보처리학회논문지B
    • /
    • 제13B권3호
    • /
    • pp.295-300
    • /
    • 2006
  • 집적 영상(Integral Imaging) 시스템은 사용자가 특수 안경을 착용하지 않고 3차원 입체영상을 볼 수 있도록 해주는 무안경식 양안시차 디스플레이 방식 중 한가지이다. 집적 영상 시스템은 3차원 정보를 조금씩 다른 방향에서 제한된 크기로 촬영된 이미지인 기초영상(Elemental Image)의 형태로 저장한다. 그리고 이런 이미지들을 다시 렌즈 어레이를 통해서 보여주어 사용자들로 하여금 3차원 정보를 얻을 수 있도록 한다. 이런 기초영상은 컴퓨터 그래픽을 이용해서 만들어낼 수도 있는데 이런 집적 영상 방식을 CG(Computer Generated) 집적 영상 시스템이라고 한다. 그리고 컴퓨터를 이용해 기초영상을 만드는 과정을 이미지 매핑(Image Mapping)이라고 한다. 이제까지 제안된 이미지 매핑 방식에는 PRR(Point Retracing Rendering), MVR(Multi-Viewpoint Rendering), PGR(Parallel Group Rendering) 등이 있다. 그러나 이런 방식들은 계산양이 많거나 렌즈 어레이 개수의 증가에 의해 생성 속도에 영향을 받는 단점이 있어, 아직 가상현실 같은 실시간 CG(Computer Graphics) 응용 분야에서 사용하기 어려운 문제가 있다. 따라서 본 논문에서는 기존의 방법에 비해 속도 향상을 이룬 VVR(Viewpoint Vector Rendering)이라는 향상된 이미지 매핑 방법을 제안한다. 먼저 VVR 개념을 설명한 후 VVR을 사용한 집적 영상 시스템을 구현하여 MVR 방법과 비교 분석한 실험결과와 추후 개선되어야 할 방향을 제시한다.

On the Vibration Analysis of the Floating Elastic Body Using the Boundary Integral Method in Combination with Finite Element Method

  • K.T.,Chung
    • 대한조선학회지
    • /
    • 제24권4호
    • /
    • pp.19-36
    • /
    • 1987
  • In this research the coupling problem between the elastic structure and the fluid, specially the hydroelastic harmonic vibration problem, is studied. In order to couple the domains, i.e., the structural domain and the fluid domain, the boundary integral method(direct boundary integral formulation) is used in the fluid domain in combination with the finite element method for the structure. The boundary integral method has been widely developed to apply it to the hydroelastic vibration problem. The hybrid boundary integral method using eigenfunctions on the radiation boundaries and the boundary integral method using the series form image-functions to replace the even bottom and free surface boundaries in case of high frequencies have been developed and tested. According to the boundary conditions and the frequency ranges the different boundary integral methods with the different idealizations of the fluid boundaries have been studied. Using the same interpolation functions for the pressure distribution and the displacement the two domains have been coupled and using Hamilton principle the solution of the hydroelastic have been obtained through the direct minimizing process. It has become evident that the finite-boundary element method combining with the eigenfunction or the image-function method give good results in comparison with the experimental ones and the other numerical results by the finite element method.

  • PDF

The Optimal Condition for Velocity Modulation

  • Park, Joon-Suk;Kim, Do-Nyun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.1157-1159
    • /
    • 2003
  • The effect of the scan velocity modulation is studied. The effect of the velocity modulation on the picture image is judged from the intensity profile of the image. The intensity profile is obtained as time integral of moving Gaussian beam. To confirm the applicability of this integral formula, the measurement and simulation data is compared. And by calculating the intensity profile for different amounts of velocity modulation, the optimum modulation displacement that gives the best image quality is obtained. This optimum modulation displacement can be used in designing scan velocity modulation system.

  • PDF

Real-Time All-Optical Three-Dimensional Image Projector

  • Jang, Ju-Seog;Javidi, Bahram
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.285-288
    • /
    • 2002
  • We propose the use of synchronously moving micro-optics (lenslet arrays) for image pickup and display in three-dimensional integral imaging to overcome the upper resolution limit imposed by the Nyquist sampling theorem. With the proposed technique, we present an all-optical three-dimensional integral imaging projector. An optically addressed spatial light modulator is used, which potentially provides better image resolution than the conventional CCD and liquid crystal display pair. We present experimental results using a liquid crystal light valve.

  • PDF

3D Visualization Technique for Occluded Objects in Integral Imaging Using Modified Smart Pixel Mapping

  • Lee, Min-Chul;Han, Jaeseung;Cho, Myungjin
    • Journal of information and communication convergence engineering
    • /
    • 제15권4호
    • /
    • pp.256-261
    • /
    • 2017
  • In this paper, we propose a modified smart pixel mapping (SPM) to visualize occluded three-dimensional (3D) objects in real image fields. In integral imaging, orthoscopic real 3D images cannot be displayed because of lenslets and the converging light field from elemental images. Thus, pseudoscopic-to-orthoscopic conversion which rotates each elemental image by 180 degree, has been proposed so that the orthoscopic virtual 3D image can be displayed. However, the orthoscopic real 3D image cannot be displayed. Hence, a conventional SPM that recaptures elemental images for the orthoscopic real 3D image using virtual pinhole array has been reported. However, it has a critical limitation in that the number of pixels for each elemental image is equal to the number of elemental images. Therefore, in this paper, we propose a modified SPM that can solve this critical limitation in a conventional SPM and can also visualize the occluded objects efficiently.

퍼지적분을 이용한 단백질패턴에 관한 특징추출 (Feature Extraction for Protein Pattern Using Fuzzy Integral)

  • 송영준;권혁봉;김미혜
    • 한국콘텐츠학회논문지
    • /
    • 제7권1호
    • /
    • pp.40-47
    • /
    • 2007
  • 단백질 매크로 어레이 영상에서 단백질 칩 각각의 특징을 규명하는 것은 중요한 것이다. 사람의 시각에 의한 판단은 많은 단백질 칩 영상을 실험할 경우, 장시간의 관찰과 그로 인한 오류가 발생할 수 있다. 따라서 시뮬레이터를 통한 특성 파악이 필요하게 되고, 매크로 어레이 스캔 영상에 대해 특성 분석을 할 경우 효율을 극대화할 수 있다. 형광 스캔 영상에 있어서, 각 셀의 반응도는 컬러 영상의 R, G, B 분포에 의존하여 왔다. 그러나 중첩되는 영상의 경우는 한쪽으로 구분하여 분류하기가 어렵다. 본 논문은 이러한 단점을 극복하기 위해 사용자가 원하는 색상에 대한 퍼지 측도 값을 적용한 퍼지 적분 값으로서 단백질 칩의 반응색상을 구분 지었다. Scan Array 5000에 의해 구성된 매크로 어레이 형광 영상들에 대해 실험한 결과, 퍼지 적분을 사용한 제안 방법이 모호한 색상에 대해 결정을 내릴 수 있는 요소가 됨을 보여 주었다.

2차원 참조 기법을 이용한 3D 컬러 집적 영상의 압축 (Compression of 3D color integral images using 2D referencing technique)

  • 김종호;유훈
    • 한국정보통신학회논문지
    • /
    • 제13권12호
    • /
    • pp.2693-2700
    • /
    • 2009
  • 본 논문에서는 렌즈 배열에 의한 대용량의 3차원 집적 영상을 활용하기 위한 효율적인 압축 방법을 제안한다. 기존의 정지영상 압축 기법은 각 요소 영상간의 상관도를 적절하게 제거하지 못하여 압축 효율 및 화질 측면에서 낮은 성능을 보인다. 또한, 각 요소 영상을 1차원 스캔방법에 의해 분리하여 동영상 압축기법을 이용할 경우 요소 영상간 상관도를 효과적으로 제거하는 데 한계가 있다. 제안하는 방식에서는 2차원 참조기법에 의해 각 요소 영상을 분리하고, 이를 H.264/AVC의 다중 프레임 참조 기법을 이용하여 효과적으로 압축한다. 제안하는 2차원 참조 기법은 요소 영상의 수직, 수평 및 대각 방향의 상관도에 따라 최적의 참조 영상을 선택할 수 있어 가장 좋은 압축성능을 나타낸다. 실험 결과는 정지 영상 압축 방법에 비해 요소 영상을 분리하는 방법이 압축 성능을 향상시킴을 보이고, 제안하는 2차원 참조 기법이 1차원 스캔 방식에 비해 주관적 화질 및 객관적 성능에 있어 뛰어남을 보인다.

Computational integral imaging reconstruction by use of scale-variant magnification technique

  • Shin, Dong-Hak;Yoo, Hoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.726-729
    • /
    • 2008
  • In this paper, we present an interference problem among elemental images in computational integral imaging reconstruction. To overcome the interference problem, we propose a method to calculate a minimum magnification factor and the preliminary experiments are performed.

  • PDF