A Numerical Study for Optimum Design of Dust Separator Screen Based on Coanda Effect (코안다효과를 이용한 제진기 스크린의 최적설계를 위한 수치적 연구)

  • Yun, Seong-Min;Kim, Yong-Sun;Shin, Hee-Jea;Ko, Sang-Cheol
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.6
    • /
    • pp.177-185
    • /
    • 2018
  • There is a need to study dust separator screens with good drainage efficiency while effectively filtering suspended solids and other contaminants entering the intake pumping station, the drainage pumping station and the mediation pumping station, the cooling water inlet of the power plant, and the like. In this paper, Numerical studies were conducted for the optimal design of the dust separator screen using the Coanda effect. The shape of the dust separator screen is important, such as the right curvature radius $R_1$ at the top of the dust separator screen and the left curvature radius $R_2$ at the top, h is the height difference and shape between the screen and the accelerating plate, and ${\theta}$ is the inclination angle of the screen. A total of 4 shape factors were set and the effects of Coanda and drainage performance of each element were compared and analyzed, the optimum length and size of each shape element were derived by classifying the shape elements into direct and indirect influences. Finally, it was possible to effectively filter foreign matter by narrowing the screen spacing, and the drainage performance was analyzed and optimized through numerical studies of dust separator screen.

Water Quality Improvement in the River through Reformation of Irrigation Water Supply Systems (관개용수 공급체계 변경을 통한 하천의 수질개선)

  • Lee, Kwang-Ya;Kim, Hae-Do;Lee, Jong-Nam;Park, Jong-Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.540-545
    • /
    • 2006
  • The objective of the study is to assess the water quality improvement resulted from the rearrangement of the irrigation water supply systems at Mankyeong River and Ansung Chun basin. There is a mixed type of watershed composed of urban and rural areas in the region. The water intake facilities for agricultural use such as reservoir, weir and pumping station are generally located at upstream river where the water quality maintains relatively clean. However, this study focuses on moving the water intake to downstream and rearranging the irrigation water supply system, then investigating how effective they are for water quality improvement in the river. When the water intake is moved downstream, the stream flow is increased as much as the amount of irrigation water that is to be taken upstream. The augmented flow which is frequently referred to as environmental flow can function as dilution water for improving the quality of polluted water that is originated from the wastewater in tributaries.

  • PDF

Using of Riverbed Filtration for Intake System (기술사마당 - 하상여과를 이용한 간접취수 확보방안)

  • Lee, Sang-Soo
    • Journal of the Korean Professional Engineers Association
    • /
    • v.42 no.3
    • /
    • pp.47-53
    • /
    • 2009
  • Riverbed filtration(RBF) system is used to develop ground water and infiltrated water supplies from permeable sand and gravel deposits. RBF plants are constructed with a reinforced concrete caisson that serves as a wet well pumping station. The lateral well screens are projected horizontally into waterbearing deposits from inside the caisson. Riverbed filtration(RBF) is a low-cost and efficient alternative water treatment for drinking-water applications.

  • PDF

The Effect of Pump Intake Leaning Angle and Flow Rate on the Internal Flow of Pump Sump

  • Lee, Youngbum;Kim, Kyung-Yup;Chen, Zhenmu;Choi, Young-Do
    • The KSFM Journal of Fluid Machinery
    • /
    • v.20 no.1
    • /
    • pp.74-80
    • /
    • 2017
  • Pump sump system or pumping stations are built to draw water from a source such as river and used for irrigation, thermal power plants etc. If pump sump is improperly shaped or sized, air entraining vortices or submerged vortices may develop. This may greatly affect pump operation if vortices grow to an appreciable extent. Moreover, the noise and vibration of the pump can be increased by the remaining of vortices in the pump flow passage. Therefore, the vortices in the pump flow passage have to be reduced for a good performance of pump sump station. In this study, the effect of pump intake leaning angle and flow rate on the pump sump internal flow has been investigated. There are three cases with different leaning angle. Moreover, a pipe type with elbow also has been studied. The flow rate with three classes of air entraining vortices has been examined and investigated by decreasing the water level. The result shows that the air entraining vortices easily occurs at the pump intake with large leaning angle. Moreover, the elbow type of the pump intake easily occurs air entraining vortices at the high flow rate (or velocity) in comparison to other pump intake type.

Methodology for Estimating Agricultural Water Supply in the Han River Basin (한강수계의 농업용수 공급량 조사방법의 개발)

  • Im, Sang-Jun;Park, Seung-U;Kim, Hyeon-Jun
    • Journal of Korea Water Resources Association
    • /
    • v.33 no.6
    • /
    • pp.765-774
    • /
    • 2000
  • The purpose of this study are to develop a realistic methodology to estimate agricultural water supply for rice paddy fields from reservoirs, pumping stations, intake structures, and tube wells on river basin scale. Agricultural water supply from irrigation reservoirs are estimated using the daily or ten day's storage rate data and DIROMmaily Inigation Reservoir Operation Model) model. Estimation of daily water supply from pumping station are carried out from the annual water use with typical water supply patterns. The daily groundwater withdrawn are investigated from the gross water requirement for rice and the design capacity of tube well. And, the daily intake discharge are estimated the minimum amount from the gross water requirement, stream discharge, and the design capacity. During 1993 to 1997, the annual water supply for irrigation in the Han river basin ranged from 569 to 709 million $\textrm{m}^3/yr$, and the mean was estimated to be 640 million $\textrm{m}^3/yr$.

  • PDF

Recovery Increase by Recycling Backwash Residuals in Microfiltration System

  • Yu, Myong-Jin;Pak, Hong-Kyoung;Sung, Il-Wha
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.4
    • /
    • pp.13-21
    • /
    • 2008
  • With the rise in membrane applications, residuals management has become a growing challenge for membrane system. The primary residuals of MF/UF (microfiltration/ultrafiltration) system results from the wastes generated during backwashing. Many regulatory agencies, utilities, and water process engineers are unfamiliar with the characteristics and methods for treatment and disposal of membrane residuals. Therefore, this study was performed to investigate the backwash residuals water quality from the pressurized system with and without pre-coagulation, and to suggest approaches for the backwash residuals treatment. Pressurized MF system was installed at Guui water intake pumping station and operated with raw water taken from the Han River. We compared performances with and without the recycling backwash residuals at flux conditions, 50 LMH and 90 LMH with and without pre-treatment (coagulation). Based on the results, recycling of backwash residuals in pressurized system with pre-coagulation showed applicability of backwash residuals managements. Moreover, the recovery rate also increased up to over 99%.

Insulation Analysis of Starting Reactor for High Voltage Induction Motors (고압유도전동기용 기동리액터의 절연진단)

  • Lee, Eun-Chun;Kim, Tae-Ho;Buyn, Il-Hwan;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.61-62
    • /
    • 2006
  • Since the starting reactor used for reducing inrush current of high voltage induction motor applies an electric current only when it is at the stage of transition, it gets lots of electrical or mechanical stress. In this aspect, the reliability on the starting reactor is very important because the reactor-relating-accident takes 80% of all the accident concerned with high voltage motor starting panel. In this study, we conducted an insulation test of starting reactor of high voltage induction motor of intake pumping station to the Seoul area And the result from this study was used as data for determining whether it's still usable or not.

  • PDF

A study on the applicability of power usage method for the analysis of river water intake (하천수 취수량 분석을 위한 전력량법의 적용성 연구)

  • Baek, Jongseok;Kim, Chiyoung;Cha, JunHo;Song, Jaehyun
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.12
    • /
    • pp.975-984
    • /
    • 2019
  • As an essential prerequisite for systematic and integrated management of river water, it is necessary to secure the basic data such as discharge supplied to the river and released from the river. Under the current permit system for river water use, 59.1% of licensed facilities were found to have no discharge meters in 2017, especially for agricultural water, which makes it difficult to secure reliable data as a large portion of the reports are voluntarily reported by users. In this study, the indirect discharge measurement method of calculating the discharge through the power usage of the pumping station was applied to secure reliable discharge data. In particular, focusing on the fact that the discharge calculated by the power usage method differed with the actual discharge according to the level of the river, the study was conducted on improving the power usage method reflecting the river water level and improving the accuracy of discharge data. Analysis of the discharge calculated using the power usage method considering river water level using the correlation analysis method such as regression analysis, percent difference, root mean square error etc. confirmed that the results are not high compared to the conventional power usage method, but are slightly more approximated to the actual discharge. Therefore, although reliable discharge data can be obtained from the existing power usage method, it is expected that more accurate data on intaking water of river water can be obtained if the improved power usage method is used at points where the variation in the water level of the river is large.

Development of Smart Remote Terminal Unit for Water Treatment SCADA System (상하수도 원격감시제어 시스템 구현을 위한 스마트 RTU의 개발 및 적용)

  • Jang, Sang-Bok;Lee, Ho-Hyun;Hong, Sung-Taek;Chun, Myung-Geun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.2
    • /
    • pp.24-30
    • /
    • 2014
  • In this paper, a new remote terminal unit(hereafter RTU) is proposed to manage a wide range of applications and a variety of sensors (eg, pressure, water quality, temperature and humidity sensors, the amount of pollutants, $CO_2$, etc.) to monitor and control the facility such as water treatment plant, intake and effluent pumping station, water tank and distribution network. Fault status of local sensor devices and network are alerted by using the embedded fault handling capabilities of the RTU in the system and also sent to the fault handling server, by which fault can be easily monitored to users. The developed system was applied to one of K-water branch offices in Geoje city and improved its reliability and stability for controlling and monitoring water facility.

The plan of depreciation vortex developing a Pump suction Pipes through Sump model test (수리모형실험을 통한 펌프 흡입배관부 보텍스 현상 저감방안)

  • Ahn, IS;Kim, SH;Kim, KY;Roh, HW;Lee, YH
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.193-198
    • /
    • 2004
  • In general, the function of intake structure, whether it be a open channel, a fully wetted tunnel, a sump or a tank is to supply an evenly distributed flow to a pump station. An even distribution of flow, characterized by strong local flow, can result in formation of surface or submerged vortices, and with certain low values of submergence, my introduce air into pun, causing a reduction of capacity and efficiency, an increase in vibration and additional noise. This study investigated experimentally the formation of the vortex to understand the mechanism of vortex formation and to prevent the formation of vortex in the sump model using by the model test and PIV tool. Sump model was manufactured to 1/8 scale with the drawing of W intake pumping station. from the results of model test and PIV, the vortex were occurred the in the whole section. Thus, sump model tests with the anti-vortex device might be considered to prevent the formation of vortex in the sump model.

  • PDF