• Title/Summary/Keyword: Insulators

Search Result 652, Processing Time 0.034 seconds

Analysis on Properties of Porcelain Insulators with Alumina Composition (알루미나 조성에 따른 송전용 자기애자의 특성 분석)

  • Cho, H.G.;Lee, Y.J.;Yoon, H.S.;Han, S.W.;Choi, I.H.;Choi, Y.K.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.317-318
    • /
    • 2005
  • This paper presents the analysis on the properties of porcelain insulators with the manufactured year. The domestic porcelain insulators manufactured in 1995, 1997, and 2002 and the imported one are prepared. The content of alumina was increased with the manufactured year, and the hardness of ceramic parts showed the same trend. Moreover, the distribution and the size of pore were more decreased and reduced on the junction parts between the glaze and the ceramic. Therefore, we concluded that the domestic porcelain insulators have been improved with the lapse of time.

  • PDF

Evaluation of Ageing Characteristics of Polymeric Insulators for Distribution Lines by Tracking Wheel Test (Tracking wheel 시험을 통한 배전용 폴리머애자 열화특성 평가)

  • Lee, Byung-Sung;Han, Jae-Hong;Han, Yong-Heui;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2314-2316
    • /
    • 1999
  • This study describes the results of aging characteristics of polymer insulators through the tracking wheel test. In order to evaluate the reliability of polymer insulators, 4 polymer insulators which used in the field were selected. Electrical tests such as power frequency voltage test, steep-front impulse voltage test were performed after tracking wheel test. Chemical structure and contact angle were measured for investigating an aging characteristics. Although some changes have occurred on the surface of insulator, there are no critical changes between new and tracking wheel tested insulator.

  • PDF

The analysis of leakage current characteristics of polymer insulators for estimation under Pollution conditions (고분자 절연물의 내오손 진단을 위한 누설전류 특성 해석)

  • Kim, I.S.;Han, S.W.;Cho, H.G.;Soh, J.J.;Kim, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1452-1454
    • /
    • 1997
  • Properties of flashover in polymer insulators are very important under pollution environments. It is necessary to analyse flashover characteristics whether insulators are still safe or not. A lot of precious information can be got out of polluted polymer insulators through leakage current measurement. The behavior of partial arc discharge leads to flashover directly. It is possible to measure partial arc discharge as leakage current pulses analysis. The shape of histogram reflects degree of pollution, wetting and voltage stress level. It can be expressed by Weibull distribution function.

  • PDF

Pre-Flashover of Alumina in Vacuum (진공 중에서 알루미나의 플래쉬오버)

  • Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.375-376
    • /
    • 2008
  • The flashover of insulators in vacuum is the main factor to limit the performance of insulation in vacuum insulation system. It is believed that the pre-flashover phenomena would play a very important role in the procedure of the flashover in the interface between the insulators and vacuum. This paper is mainly concerned on the pre-flashover phenomena of Alumina insulators in vacuum. There are 24 different types of alumina insulators were tested with a 0.7/4 ${\mu}s$ pulsed voltage under a $1\times10^{-4}$Pa vacuum. The observed pre-flashover phenomena were classified and the pre-flashover characteristics were concluded. It is useful to study further on the flashover mechanism in vacuum.

  • PDF

The Effect of the Non Soluble Industrial Dust on the Electrical Properties of Distribution Porcelain Suspension Insulators (비용해성 산업용 분진이 배전용 자기제 현수애자의 전기적 특성에 미치는 영향)

  • Kim, Chan-Young;Song, Il-Keun;Kim, Ju-Yong;Han, Jae-Hong;Kim, Dong-Myung;Lee, Byung-Sung
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.4
    • /
    • pp.182-189
    • /
    • 2001
  • In this paper, the distribution suspension porecelain insulators which had been used for long periods in the contaminated area were evaluated. The contaminated area is close to the sea and in the high density of industries. The heavily contaminated domestic and imported insulators were investigated by using electrical characteristics, such as power-frequency dry flashover voltage, power-frequency wet, flahover voltage, and leakage current. Also, these electrical results were compared with the contaminants on the surface. From these analysis, we found that the contamination from the industrial dust, only slightly decreased flashover voltage and increased leakage current. Therefore, the electrical properties of insulators used for 30 years in the area of coast and industrial complex were not much changed.

  • PDF

The Design Analysis and Electrical Performance Test of Polymer LP Insulator (폴리머 LP애자의 설계해석과 전기적 성능 시험)

  • 이운용;조한구;박상호;송홍준
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.399-401
    • /
    • 2000
  • Recently polymer insulators are being used for outdoor high voltage applications. Polymer insulators for transmission and distribution line have significant advantages over porcelain and glass insulators, especially for ultra-high voltage(UHV) transmission lines. Their advantages are light weight, vandalism resistance and hydrophobicity. In this paper, polymer line post insulator has been designed and investigated electric field distribution by FEM. Designed LP insulators have been tested as insulator performance test, such as power frequency voltage test, lightning impulse voltage test, artificial pollution test and flexural load test.

  • PDF

Characteristic Analysis of Suspension Insulators for Distribution Line (배전용 현수애자의 특성분석)

  • 김찬영;김주용;송일근;이병성
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.3
    • /
    • pp.259-264
    • /
    • 2000
  • The paper provides the characteristic analyses of porcelain suspension insulators. The comparisons of characteristics were made as a function of failed and unfailed insulators which had ben used in the fields. This paper also describes the failure modes occurred in the fields. The aging of cement corrosion of metal breaking of shed puncture in the head and separation of glaze are different failure modes for porcelain suspension insulators. Among these failure modes the puncture breaking and glaze problems were major concerns in this research. The cracks porosities of porcelain and micro-crystals on the graze were the causes of these failures. These results were confirmed by conducting various failure analyses.

  • PDF

Analysis of Polymeric Insulators Exposed to In-service Conditions (실 포설 환경에 노출된 송전용 고분자애자의 평가)

  • Lee, Sang-Jin;Youn, Bok-Hee;Bai, Kyoung-Moo;Jeon, Seung-Ik
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.248-250
    • /
    • 2004
  • We have investigated the surface state of 154kV polymeric insulators exposed to in-service conditions for about five years. In order to evaluate surface aging of silicone rubber exposed to real field environments, we used various analytic methods such as contact angle, ATR-FTIR, SEM-EDS. Although contaminants were accumulated on weathershed surface, polymeric insulator has retained its intrinsic surface hydrophocity. In addition, ATR-FTIR confirmed the diffusion layer of a low molecular weight silicone fluid on surface layer and no surface cracking and chalking were Indicated by SEM. Polymeric insulators have still retained their improved pollution performance over porcelain insulators. That will lead to very low frequency of flashovers throughout their useful life, often under contaminated conditions.

  • PDF

The Dielectric Analysis of Insulators for Home Appliances (가전설비용 절연재의 유전열 분석)

  • Jung, Jin-Soo;Jung, Jong-Wook;Yi, Gun-Ho;Bae, Seok-Myung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.206-207
    • /
    • 2006
  • This paper describes the dielectric analysis of several insulators for home appliances. The dielectric characteristics of ABS(acrylonitrile butadiene styrene) were tested in relative permittivity, dielectric loss($tan{\delta}$) and specific resistance and compared with those of the other 4 insulators of PE(polyethylene) series. As a result, the relative permittivity of only the ABS slightly decreased with temperature. In the case of the tan6, the ABS showed higher dielectric loss than the other insulators but more excellent thermal performance. In addition, its changing pattern in specific resistance was very similar to that in $tan{\delta}$.

  • PDF

A Simulation for Kaolin Contaminants Accumulation and Varying Characteristics of Leakage Currents (Kaolin 오손물 누적량 모의실험 및 누설전류변화 특성)

  • ark, Jae-.Jun;Song, Il-keun;Lee, Jae-bong;Chun, Sung-nam
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.11
    • /
    • pp.483-489
    • /
    • 2005
  • This study performs a simulation for an accumulation mechanism of contaminants, which were produced in an industrial belt of inland, on the surface of insulators. From the simulation, silicon insulators presented higher accumulation than that of EPDM(Ethylene Propylene Diene Terpolymer : EPDM) insulators on the same distance in the case of the Virgin polymer insulator, and this result presented the same result in the insulator applied in actual fields. In the case of the accumulation test for the Virgin insulator and insulators used in actual fields, it is evident that the Virgin insulator presented more accumulation than that of the insulator used in actual fields. The results can be caused by the generation of LMW (Low Molecular Weight) on the external material of polymer insulators, and the level of the accumulation can be changed according to the degree of the continuous generation of LMW. In order to simulate a certain pollution of an industrial belt, which is located along the coastline, leakage currents were measured by applying the contaminant compulsively that was produced with salts and Kaolin according to the ratio of its weight on the surface of insulators. The more increase in the content of Kaolin pollution, the level of leakage currents on the surface of polymer insulator more increased. In addition, the approaching time to the maximum value of leakage currents presented a nearly constant level regardless of the content of Kaolin. The level of leakage currents significantly decreased according to the passage of time, and the level of leakage currents on the surface maintained a constant level at a specific time regardless of the content of Kaolin.