• 제목/요약/키워드: Insulator inspection

검색결과 32건 처리시간 0.024초

활선애자점검기의 개발 및 154kV 선로에의 적용 - 제1부 : 점검기 개발 (Development of Live-line Insulator Tester and Its Application to 154kV Power Lines - Part 1 : Tester Development)

  • 이재경;박준영;조병학;오기용
    • 전기학회논문지P
    • /
    • 제59권1호
    • /
    • pp.83-88
    • /
    • 2010
  • A new live-line insulator tester was developed to detect faulty insulators in 154kV power transmission lines. This paper is the first part of the two-part paper and deals with its tester development. The developed tester has the following characteristics. First, it automates parts of the insulator inspection process by using a sensor and an actuator, and secondly, it sustains its weight by itself, not by a lineman. Finally, it measures the insulation resistance of an insulator together with its distribution voltage to provide more information for its analysis and diagnosis. These leads to the improvement of its operation efficiency, measurement reliability and usability. Its effectiveness was validated by live-line field tests in actual power lines.

UV 센서 어레이를 이용한 폴리머 애자의 코로나 방전 신호분석 연구 (A Study on the Signal Analysis of Corona Discharge on the Polymer Insulator using UV Sensor Array)

  • 최명일;김재철
    • 조명전기설비학회논문지
    • /
    • 제28권4호
    • /
    • pp.16-20
    • /
    • 2014
  • To prevent any accident in electric power utilities, many researches for inspection and diagnosis deteriorations occurring by corona discharges have been continuously studying. Inspection and diagnosis of electric power utility is very important to prevent an accident. This paper studies a measurement of ultra-violet(UV) ray of corona discharges on polymer insulators using an UV sensor array with an optic lens. The detection of an UV signal begins at 60kV, which is about 37.5% of the breakdown voltage of the polymer insulator and the stronger the high voltage increased to the polymer insulator was. It can be determined that the polymer insulator mounted on a live part must be examined when the discharge risk exceeds approximately 40%. In conclusion, the status of power utilities can be checked using an UV sensor.

국내 기후와 환경에 적합한 터널브래킷 선정에 관한 연구 (A Study on the Appropriate Tunnel Bracket using in Korea Peninsula)

  • 장광훈;서기범
    • 전기학회논문지
    • /
    • 제63권7호
    • /
    • pp.1008-1012
    • /
    • 2014
  • Tunnel bracket is used in railway tunnel area in order to maintain insulation. Insulator performance evaluation test is proceeded refer to IEC 61109 but it is impossible to reflect all the field condition where insulator installed. Korea has clear four season in climatic condition and peninsula with lots of mountain in geomorphology condition. Tunnel bracket material which used in korea are butyl rubber, polymer and silicone. Most of them were installed without any internal climatic and geomorphology condition. According to the KORAIL operation data most of the insulator break down occurs in tunnel. So interval of inspection period is shorter then any other insulator and lots of maintenance cost incurs. Most major railway advanced country such as germany and japan maintain tunnel bracket with their own experience. For example visual inspection carried out with in one or two years and detailed inspection carried out between three to five years. This paper analyzed materials and shapes of tunnel bracket to in order to find optimized one in korea peninsula. Proposed bracket were tested under regulation and experience field data. Finally it was installed at the field and evaluated until now.

방음재를 삽입한 합성슬래브의 수평전단성능에 관한 실험적 연구 (An Experimental Study on Longitudinal Shear Capacity of Composite Slab Embedded with Silence Insulator)

  • 이선근;이치형;윤성기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권5호
    • /
    • pp.64-71
    • /
    • 2018
  • 본 연구는 방음재를 삽입한 새로운 개념의 합성슬래브 시스템을 제안하고, T-형 바의 폭, 전단보강 철근의 설치 등을 실험의 주요변수로 한 총 7개의 실험체를 제작 Push-Down실험방법으로 수행한 수평전단성능에 대한 실험 결과를 제공하고 있다. 실험결과 T-형 바를 전단키로 적용하고 방음재를 삽입한 실험체가 기본실험체에 비해 수평전단성능에서 2배 이상 우수한 것으로 나타났다. 이는 제안한 합성슬래브상세를 실제 현장 적용하여도 기존의 합성슬래브 보다 구조적 측면에서 상당한 안전율을 확보할 것으로 생각되며, 내진동 및 방차음의 개선에도 크게 기여할 것으로 판단된다.

방한용 화섬솜의 섬도 측정방법의 표준화에 관한 연구 (A Study on the Standardization of Fineness Measurement for the Thermal Insulator of Military Textiles)

  • 홍성돈;김병순
    • 품질경영학회지
    • /
    • 제43권3호
    • /
    • pp.253-272
    • /
    • 2015
  • Purpose: The purpose of this study is to enhance the reliability of quality inspection by standardize the fineness test method of the thermal insulator of military textiles Methods: We have measured the thermal insulator of military textiles by microscope with three different ways and the effectiveness of their difference were analyzed by one-way layout design. Results: We have suggest the standardized the fineness test method of the thermal insulator of military textiles through advanced research. As a result we have verified hollow ratio of heat insulating fiber affect fineness test methods. The fineness test method for the thermal insulator applied with different methods following hollow ratio. We have verified that when the hollow ratio over 90%, the fineness of the thermal insulator measured from fiber-length, if it has over 80%, the cross-section length of hollow and if it has less 80%, the cross-section area of hollow is applied, respectively. Conclusion: This study indicated that the test method of fineness shows high reliability. Heat insulating fibers which have high evenness shows narrow variations(5/% or less, only CV 25%) irrespectively under different testing equipment or institute. Based ons the results, we have suggest the standardization of test methods for fineness by microscope method and produced the registration of Group Standard in Korean Standards Association.

고조파 추출을 이용한 불량애자 검출장치 개발연구 (Defective Porcelain Insulator Inspection Based on Harmonic Retrieval)

  • 로호;김홍철;한순신;이장명
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2007년도 하계종합학술대회 논문집
    • /
    • pp.291-292
    • /
    • 2007
  • Porcelain insulators are widely used in overhead high-voltage power transmission lines while providing adequate insulation to withstand switching and lightning over voltages. For the safety consideration, we proposed a novel insulator inspection method using harmonic, which is retrieved from the low frequency signal. The working principle of this new method is based on the relationship between the low frequency harmonic and the defective characteristic of the insulators. So, in this paper, the harmonic retrieval in the complex noise is solved with the HOC (High Order Cumulants) is extended. In the experiment, as one of our dedicated contribution, we illustrate low frequency harmonic and the defective characteristics of the porcelain insulators.

  • PDF

연면방전에 의한 폴리머애자의 자외선 발생과 열화특성 (The Characteristics of UV Generation and Aging Materials in According to Surface Discharge)

  • 송길목;방선배;김종민;김영석;정진수
    • 전기학회논문지
    • /
    • 제57권9호
    • /
    • pp.1606-1611
    • /
    • 2008
  • Recently, The diagnosis techniques of electric facilities are developed on live line. This paper describes the discharge characteristics of polymer insulator(EPDM A type). Keeping the facilities in good working order, the goal of this paper will provide the information to enable user to easily judge conditions of facilities on the spot. The performance of polymer insulator is assessed from the KS C IEC 60270 and CEA LWIWG-01(96)(Tracking Wheel Test). As the results, UV generation patterns of polymer insulator grow like a jellyfish shape follow the ramping voltage. Discharging UVs are detected at about 31.25% of breakdown voltage. Just then, dimension of UV image is about $0.84cm^{2}$. The dimension of max. UV image is about $297.4cm^{2}$ at $160kV(V_{bd})$. The position of UV generation due to surface discharge of polymer insulator is the center of insulator in the early, then moved the ground side and the last, UV image moved through the junction part of source side. Surface of aged polymer insulator is cracked and faded due to arc. UV absorption spectrum of polymer insulator are appeared the C-H bond of scissoring vib. at $1014cm^{-1}$ and C=O bond of recombination structure. Also, recombined UV absorption peak such as C-H, N-H, and O-H is detected at the $3321cm^{-1}$. Through the paper, there are inspection data which are the relations between surface discharge of polymer insulator and UV detecting image.

Microphone Array와 열화상 카메라를 이용한 고압설비 고장검출 (Malfunction Detection of High Voltage Equipment Using Microphone Array and Infrared Thermal Imaging Camera)

  • 한순신;최재영;이장명
    • 제어로봇시스템학회논문지
    • /
    • 제16권1호
    • /
    • pp.25-32
    • /
    • 2010
  • The paper proposes a hierarchical fault detection method for the high voltage equipment using a microphone array which detects the location of fault and the thermal imaging and CCD cameras which verifies the fault and stores the image, respectively. There are partial arc discharges on the faulty insulators, which generates a specific pattern of sound. Detecting the signal using the microphone array, the location of the faulty insulator can be estimated. The 6th band-pass filter was applied to remove noise signal from wind or external influence. When the mobile robot carries the thermal and CCD cameras to the possible place of the fault insulator, the fault insulators or power transmission wires can be detected by the thermal images, which are caused by the aging or natural erosion. Finally, the CCD camera captures the image of the fault insulator for the record. The detection scheme of fault location using the microphone array and the thermal images have been proved to be effective through the real experiments. As a result of this research, it becomes possible to use a mobile robot with the integrated sensors to detect the fault insulators instead of a human being.

프랙탈 수학을 이용한 옥외용 설비의 정량적 평가법 제안 (The New Estimation Methods for Outdoor Equipment using Fractal Mathematics)

  • 박범수;임장섭;소순열;이진;송일근;이재봉
    • 한국전기전자재료학회논문지
    • /
    • 제20권2호
    • /
    • pp.183-187
    • /
    • 2007
  • Fractal mathematics is being highlighted as a research method for classification of image. But the application of Fractal dimension(FD) has been requited the complicated calculation method because of its complex repetition progressing. In this paper, it has been developed the new approach method to express the Fractal Dimension(FD) for aging level calculation and estimation system of outside insulator using special image processing algorithm. As a result after FD testing, the recognized aging estimation of FD has a very characteristics compared to the conventional visual inspection.

이동통신망의 SMS방식을 이용한 변전기기 무선진단 시스템 개발 (Development of Wireless Diagnostic System for Substation Equipments Using SMS Mode of Mobile Communication Network)

  • 김진철;김지호;윤만식;송호준;이향범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.259-261
    • /
    • 2003
  • This paper suggests wireless diagnosis and monitoring system using SMS mode of mobile communication network for distribution transformer which could prevent electrical accident in the near future. Data are acquired by measuring the temperature of insulator oil in the distribution transformer and load current. Data acquisition of sensor using mobile communication network carried out filtering of sensor's output to optimize the size of send data Merit of this inspection method is that management, control and monitoring some transformers can be carried out using only one server. This inspection method will be the way of inspection to be worth spotlight in the near future because it is able to solve easily with the minimum facility inspection about state of transformer which is operating, to wide coverage about machine's wrong operation in other field.

  • PDF