Abstract
Tunnel bracket is used in railway tunnel area in order to maintain insulation. Insulator performance evaluation test is proceeded refer to IEC 61109 but it is impossible to reflect all the field condition where insulator installed. Korea has clear four season in climatic condition and peninsula with lots of mountain in geomorphology condition. Tunnel bracket material which used in korea are butyl rubber, polymer and silicone. Most of them were installed without any internal climatic and geomorphology condition. According to the KORAIL operation data most of the insulator break down occurs in tunnel. So interval of inspection period is shorter then any other insulator and lots of maintenance cost incurs. Most major railway advanced country such as germany and japan maintain tunnel bracket with their own experience. For example visual inspection carried out with in one or two years and detailed inspection carried out between three to five years. This paper analyzed materials and shapes of tunnel bracket to in order to find optimized one in korea peninsula. Proposed bracket were tested under regulation and experience field data. Finally it was installed at the field and evaluated until now.
Keywords
Tunnel bracket; Polymer; KORAIL;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Young sik Park et, al., Management method of pollution area(tunnel, sea side) catenary system insulator, KORAIL Electrification department., Aug. 2013.
2 Yong Joo Jeon et, al., "A study on the tunnel bract insulator pollution characteristic", KORAIL Research institute, Aug. 2009.
3 Young Sik Park et, al., Management method and future plan of Tunnel bracket insulator, KORAIL Electrification department., Dec. 2008.
4 KORAIL, "2013 Civil work present" KORAIL Civil engineering division, 2013.01.
5 R. Vogelsang et al., "The Effect of Barriers on Electrical Tree Propagation in Composite Insulation Materials", IEEE Trans. on DEI Vol. 13, No. 1, pp.373-382, Apr. 2006   DOI   ScienceOn
6 IEC Publ. 60112, "Recommended Method for Determining Comparative Tracking Index of Solid Insulating Materials under Moist Conditions", 2nd Ed., 1971
7 Luiz H. Meyer et al., "A Novel Technique to Evaluate the Erosion Resistance of Silicone Rubber Composites for High Voltage Outdoor Insulation Using Infrared Laser Erosion", IEEE Trans. on DEI Vol. 12, No. 6, pp.1201-1208, Dec. 2005
8 Young-Seok Kim et. al., "The Accident Hazards and Properties of the Surface Leakage Current on the Polymer Insulation caused by Salt-water and Dust", Kiiee, Vol. 21, No. 8, pp. 129-135, 2007   과학기술학회마을   DOI   ScienceOn
9 Kil-Mok Song et, al., "Conductivity Measurement According to Sampling Dusts on Spot and Risk Assessment for Electrical Installations", Kiiee autumn conference, 2007.
10 Jung-Suk Nam et, al., "A study on the safty countermeasure of electrification equipment at tunnel and factory area", KRRI, July. 1996.
11 Yong Joo Jeon etal, "A research on the Tunnel bracket insulator pollution characteristic in Korea Railroad", ICEE 2009 Shenyang, china, 2009