• Title/Summary/Keyword: Insulation systems

Search Result 416, Processing Time 0.022 seconds

Field Application of Power Cable Diagnosis System (전력케이블 열화진단기법의 현장적용)

  • Kim, Ju-Yong;Han, Jae-Hong;Song, Il-Keun;Kim, Sang-Jun;Lee, Jae-Bong;Oh, Jae-Hyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.148-151
    • /
    • 2002
  • In order to prevent the failures of underground distribution power cables we need to measure insulation condition in the field. Until now we used DC high voltage as a power source for the cable diagnosis but it was not proper method to the XLPE insulation cables because DC high voltage can affect sound insulation and can't diagnose exactly insulation degradation. For these reasons we imported isothermal relaxation current measurement system called by KDA-1 from germany but it's reliability did not proved in our URD cables. DC voltage decay measurement system was developed by domestic company but they don't have field experience. In this paper we tried to prove reliability of these two systems in the field. Through the field diagnosis and Ac breakdown test the two systems showed similar results.

  • PDF

Analysis of PD Patterns Depending on Defect Types in Insulation System (절연계의 결함별 부분방전 패턴분석)

  • Park, Chan-Yong;Kim, Hwang-Kuk;Kim, Sung-Wook;Ji, Hong-Keun;Kil, Gyung-Suk
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.912-918
    • /
    • 2009
  • In this paper, we carried out a comparative analysis of partial discharge(PD) patterns caused by deterioration of cast-resin and oil insulation systems. Various electrode systems were fabricated such as needle-needle, needle-plane and plane-plane to simulate defects that may exist in the insulation system of transformers. A low-noise amplifier which has a gain of 40 dB and a frequency bandwidth of 500 kHz $\sim$ 30 MHz (-3 dB) was designed to detect small PD signals. From the analysis of acquired PD signals, we could find that a unique PD pattern is formed according to types of defect. These data will be applied usefully to diagnose insulation condition of transformers.

  • PDF

A Study on the Insulation Characteristics of Low-Voltage Induction Motor driven by IGBT PWM Inverter (IGBT 인버터 구동 저압 유도전동기의 절연특성 연구)

  • Hwang, D.H.;Park, D.Y.;Kim, Y.J.;Koo, J.Y.;Park, T.I.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.206-210
    • /
    • 1999
  • Since the introduction of IGBT PWM inverters, many low-voltage induction motors have been driven by them. Recently, the stator winding insulation failures have attracted much concern due to high dv/dt of IGBT inverter output. In this paper, presented are the detailed insulation test results of 26 low-voltage induction motors. Six different types of insulation techniques are applied to 26 motors. The tests include PD, $tan{\delta}$, and DIV tests. Also, break-down tests by high voltage pulses are performed.

  • PDF

Analysis of Partial Discharge Signals Using Statistical and Pattern Recognition Technique (통계처리와 패턴 인식 기법에 의한 부분방전 해석)

  • Byun, Doo-Gyoon;Hong, Jin-Woong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.12
    • /
    • pp.1231-1234
    • /
    • 2006
  • In this study, we detected electromagnetic waves generated in an enclosed switchgear and applied various statistical methods for detecting signals. We calculated the various statistical factors via the appropriate statistical methods. Further, we used these statistics to recognize the characteristics for each pattern by identifying the partial discharge in each case for normal, proceeding and abnormal states. The characteristics of electromagnetic wave patterns occurred in various states at electric power facilities and were used as an output variable for more efficient diagnosis. In this paper, we confirmed that the pattern of partial discharge signal can be used as one of the factors used to analyze the insulation state and to consider while estimating diagnosis of insulation states by recognizing the signal pattern to intelligence. We will utilize the proposed diagnosis method to determine insulation degradation states.

An Evaluation of the Linear Thermal Transmittance for the Internal Insulation versus the External Insulation in Apartment Housings (공동주택의 단열형태별 선형열관류율 평가)

  • Lee, Jong-Sung;Lee, Do-Heun;Jun, Myoung-Hoon
    • Land and Housing Review
    • /
    • v.5 no.4
    • /
    • pp.315-323
    • /
    • 2014
  • In this study, thermal transmittance which is a parameter to measure the thermal performance was evaluated for an internal insulation versus an external insulation. Then the ISO regulation was applied to evaluate it, and the superiority of an external insulation was verified by the thermal transmittance values. The three zones of apartment housing were selected to evaluate the performance. (1) The junction of an outer wall and a protruded slab : If there is no a thermal bridge protection system, then the values are about same in the two insulation systems, so the protection system should certainly be installed. If it is installed, then the value for the external insulation is 2 times lower than internal system. (2) The junction of a side wall and a flat slab: The value is 0.509W/mK for the internal insulation and about zero for the external insulation. (3) The junction of an outer wall and a division wall: The value is 0.451W/mK for the internal insulation and also about zero for the external insulation. A domestic regulation that could evaluate a thermal transmittance has to be established by applying the ISO regulation for the evaluation of external insulation systems in apartment housing in the future. Additionally, the government must decide which length should be used for the national standard.

The Analysis Results of Lightning Overvoltages by EMTP for Lightning Protection Design of 500kV Substations

  • Ju Hyung-Jun;Lee Heung-Ho
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.4
    • /
    • pp.366-370
    • /
    • 2005
  • To meet increasing power demand, 500 kV power systems are under consideration in the regions of some Middle Asian countries. As the power system voltage becomes higher, the cost for the power system insulation increases significantly. 500 kV transmission systems will become the basis of a region's power system and they require much higher system reliability. Consequently, by the methods of limiting overvoltages effectively, a reasonable insulation design and coordination must be accomplished. In particular, the Substations must be constructed to be of outdoor type. In order to determine the various factors for the insulation design, the EMTP (Electro-magnetic transient program) is used for the magnification of transient phenomena of the 500 kV systems in the planned network. In this paper, we will explain the calculation results of lightning overvoltages by the EMTP for lightning protection design for the 500 kV substations. To obtain reliable results, the multi-story tower model and EMTP/TACS model are introduced for the simulation of dynamic arc characteristics.

The Basic Study on the Insulation Design of Vacuum Interrupter using Finite Element Method (유한요소법을 이용한 진공인터럽터 절연설계 기초연구)

  • Park, Chi-Young;Ahn, Hee-Il;Ham, Gil-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1635-1637
    • /
    • 1998
  • This paper describes on the basic study for the insulation design of vacuum interrupter using Finite Element Method. For the basic study of insulation design, first, the maximum electric field was calculated on each curvature radius of arc shield and electrode. Second, the maximum electric field was also calculated on applied voltage and end shield with or not. Thus, the maximum electric field calculated have an effect on curvature radius and voltage polarity.

  • PDF

Detailed Study on Insulation Coordination of a 25kV Power System Connected with a VCB and Transformer

  • Baek, Byung-San;Kim, Yong-Han
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1245-1249
    • /
    • 2017
  • Recently, unusual transformer failures have been reported in 25kV power systems connected with a VCB and transformer. In this study, performance of the protection system, dielectric strength of the transformers, characteristics of switching surges and resonance phenomena were analysed and assessed. All investigations regarding the insulation breakdown of the transformers were carried out by simulations, laboratory tests, factory tests and on-site measurements in order to thoroughly investigate the root causes. Furthermore, experimental methods for investigating the resonance phenomenon were derived and tests were conducted applying the derived method to recreate the phenomenon in the transformer. It is found that resonance between the transformer and switching surge generated by closing a VCB can initiate the breakdown of internal windings of a transformer.

Effects of Metal Particle on Dielectric Breakdown of Epoxy Insulation (금속 이물질이 에폭시 절연물의 절연파괴에 미치는 영향)

  • Jang, Yoon-Ki;Lee, Dong-Won;Kim, Jung-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.207-208
    • /
    • 2007
  • Epoxy resin insulators show a lot of advantages for electrical power apparatus. Because epoxy resin provide electrical and mechanical characteristic which is excellent, it is desirable to apply epoxy resin as a spacer and post insulation in Gas Insulated Switchgear (GIS). In this study, we have investigated the influence of surface electric field attached particle contaminated spacer surfaces under SF6 gas. Also, we performed analysis of electric field. As a result, when the particle was attached on spacer, we found out a surface electric field of characteristics.

  • PDF

Properties of Electrical Performance on Stator Coil of Traction Motor by Accelerated lest using Transient Surge (과도서지를 이용한 가속열화 시험법에 따른 견인전동기 고정자 코일의 전기적 특성 변화)

  • 박현준;장동욱;이길헌;최종선;김저우
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.9
    • /
    • pp.783-789
    • /
    • 2003
  • The winding problems of traction motor are the major determinant of motor's life. The root cause of winding failure is gradual deterioration of the insulation due to thermal, electrical, mechanical and environmental stresses. The aging of the insulation reduces the electrical and mechanical strength of the insulation. At same point, a voltage surge or mechanical shock from a traction motor start will fracture or break down the insulation. To achieve the expected life usually requires extensive laboratory evaluation of the insulation systems and the use of accelerated aging tests. There are several nondestructive test available for checking, the condition of motor insulation, the probable extent of aging, and the rate of which aging is taking place. So the insulation characteristics of stator coil were each analyzed by measurement of dielectric loss(tan$\sigma$), capacitance and partial discharge. The method of diagnosis is able to analyze the insulation condition and evaluate the life of the traction motor.