• 제목/요약/키워드: Insulation systems

검색결과 419건 처리시간 0.025초

Sound transmission of lightweight block walls and panels-Theory and Experiments

  • S Kandaswamy;A Ramachandraiah
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2004년도 춘계학술발표대회 논문집 제23권 1호
    • /
    • pp.235-239
    • /
    • 2004
  • Sound transmission either as airborne or structure borne is a potential problem that occurs in buildings either from sources within or from outside. With the expansion of real estate activities in countries like India, the need to attend sound insulation requirements also assumes greater dimensions. The focus of this research is on studying the sound transmission characteristics of building structures made of hollow blocks, neocrete block, aerocon block and prefabricated panels such as Ferrocement panel. The tests were carried out the blocks with and without plastering and their sound reduction index was measured at one-third octave frequencies. In the case of ferrocement panels, different types of systems were tested in the TL suite. Panels with cavity, with cavity ties, with insulation, with stiffeners and with plasterboard were investigated. Sound reduction index of these panels was measured with additional quantities like longitudinal wavespeed, and loss factors (internal and total loss factor). Tests were also conducted on Cypcrete wall panel and Sandwiched wooden panel in a similar way. Theoretical investigations were carried out using Statistical Energy Analysis (SEA) for the above systems. Sound reduction index was then compared between the predicted and the measured values.

  • PDF

Analysis of Voltage Stress in Stator Windings of IGBT PWM Inverter-Fed Induction Motor Systems

  • Hwang Don-Ha;Lee Ki-Chang;Jeon Jeong-Woo;Kim Yong-Joo;Lee In-Woo;Kim Dong-Hee
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권1호
    • /
    • pp.43-49
    • /
    • 2005
  • The high rate of voltage rise (dv/dt) in motor terminals caused by high-frequency switching and impedance mismatches between inverter and motor are known as the primary causes of irregular voltage distributions and insulation breakdowns on stator windings in IGBT PWM inverter-driven induction motors. In this paper, voltage distributions in the stator windings of an induction motor driven by an IGBT PWM inverter are studied. To analyze the irregular voltages of stator windings, high frequency parameters are derived from the finite element (FE) analysis of stator slots. An equivalent circuit composed of distributed capacitances, inductance, and resistance is derived from these parameters. This equivalent circuit is then used for simulation in order to predict the voltage distributions among the turns and coils. The effects of various rising times in motor terminal voltages and cable lengths on the stator voltage distribution are also presented. For a comparison with simulations, an induction motor with taps in the stator turns was made and driven by a variable-rising time switching surge generator. The test results are shown.

지중송전계통에서 절연접속함 위치 및 접지방식 변경의 효용성 평가 (Effectiveness Evaluation According to Change of IJ Joint Box Location and Grounding System in Underground Transmission System)

  • 고광만;이종범
    • 전기학회논문지
    • /
    • 제64권2호
    • /
    • pp.247-253
    • /
    • 2015
  • Dielectric breakdown accidents have been mainly occurred in the vicinity of service entrance section in underground power transmission systems. One cause among them is due to the excessive component value of sheath located around service entrance of cable. In this paper, as one of the alternative to prevent these accidents, the change of cross bond grounding system and the location change of IJ(Insulation Joint) are suggested. Also, to evaluate effectiveness of this changing system, circulating current and induced voltage of sheath were analyzed in steady and transient state. By comparison of the analytical results for the several possible changing systems, a grounding system and location of IJ which has the smallest sheath component values is proposed. In this paper, analysis to evaluate the proposed system is carried out by EMTP/ATPDraw. It can be used as a valuable operational material to prevent accident of the service entrance section in underground power transmission system.

LNGC 2차 방벽에 적용된 Aramid 섬유의 Weibull 통계 분석을 이용한 피로특성 평가 (Estimation of Fatigue Characteristics Using Weibull Statistical Analysis with Aramid Fiber on LNGC Secondary Barrier)

  • 박진형;오동진;김민규;김명현
    • 대한조선학회논문집
    • /
    • 제54권5호
    • /
    • pp.415-420
    • /
    • 2017
  • Insulation systems in Liquefied Natural Gas Carriers (LNGC) are vulnerable to sloshing impact and fatigue loads because of waves. If gas leaks into the primary barrier, the Flexible Secondary Barrier (FSB) prevents the leakage of gas in this system. Fatigue strength of the FSB largely depends on the behavior of composite materials. In this study, a new system is applied to the FSB using aramid fiber to improve the fatigue strength of the secondary barrier, with the intention of replacing conventional E-glass fibers. The manufacturing method involved varying the ratio of the aramid fiber to the E-glass fiber for optimum design of the FSB. The fatigue tests results of the secondary barrier using aramid fiber were superior to that using E-glass fiber. The statistical analysis is performed to obtain the fatigue test results and estimate the probability of failure as well as the design guideline of LNGC secondary barriers.

전동 블라인드 내장형 창호시스템 적용에 따른 공동주택 에너지 성능평가 연구 (Energy Performance Evaluation of Apartment Building in Case of Applying a Blind Integrated Window System)

  • 최경석;손장열
    • 설비공학논문집
    • /
    • 제22권7호
    • /
    • pp.429-435
    • /
    • 2010
  • Although recently revised building code requires 15~20% increased thermal insulation performance for window systems, since the code is focusing on winter heat loss, it is not satisfactory to contribute on reducing rapidly rising cooling load in summer. Window systems have great impact on building heat gain and loss. Therefore technological development for window system specialized in shading solar gain in summer is an urgent matter. This study evaluates the performance of sun shading and thermal insulation for blind integrated window system. Also, computer simulation evaluates the effect of heating and cooling energy consumption reduction for an individual unit(floor area of $85m^2$) of a multi-family housing. Physibel Voltra, a heat transfer analysis software, was used to analyse the effect of energy consumption reduction, and the energy load was converted to the cost to compare the actual effect of economical benefit.

Numerical Study of Estimating the Arrival Time of UHF Signals for Partial Discharge Localization in a Power Transformer

  • Ha, Sang-Gyu;Cho, Jeahoon;Lee, Juneseok;Min, Byoung-Woon;Choi, Jaehoon;Jung, Kyung-Young
    • Journal of electromagnetic engineering and science
    • /
    • 제18권2호
    • /
    • pp.94-100
    • /
    • 2018
  • Partial discharges (PDs) are electrical sparks that occur inside insulation between two conducting electrodes and can lead to the disastrous failure of insulation systems. To determine the location of a PD, a distributed array of UHF PD sensors is used to detect the electromagnetic (EM) signals emitted from the PD source, and the localization of the PD source can be estimated using the time difference of arrival (TDOA) between EM signals captured by the UHF PD sensor array. There are four popular methods to estimate the TDOA-the first peak method, the cross-correlation method, the energy criterion method, and the average time window threshold method. In this work, we numerically investigate the influence of noise on estimating the TDOA for the four different methods. Numerical results show that the energy criterion method is more robust against noise than other methods.

Identity-based Provable Data Possession for Multicloud Storage with Parallel Key-Insulation

  • Nithya, S. Mary V.;Rhymend Uthariaraj, V.
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제15권9호
    • /
    • pp.3322-3347
    • /
    • 2021
  • Cloud Storage is the primary component of many businesses on cloud. Majority of the enterprises today are adopting a multicloud strategy to keep away from vendor lock-in and to optimize cost. Auditing schemes are used to ascertain the integrity of cloud data. Of these schemes, only the Provable Data Possession schemes (PDP) are resilient to key-exposure. These PDP schemes are devised using Public Key Infrastructure (PKI-) based cryptography, Identity-based cryptography, etc. PKI-based systems suffer from certificate-related communication/computational complexities. The Identity-based schemes deal with the exposure of only the auditing secret key (audit key). But with the exposure of both the audit key and the secret key used to update the audit key, the auditing process itself becomes a complete failure. So, an Identity-based PDP scheme with Parallel Key-Insulation is proposed for multiple cloud storage. It reduces the risk of exposure of both the audit key and the secret key used to update the audit key. It preserves the data privacy from the Third Party Auditor, secure against malicious Cloud Service Providers and facilitates batch auditing. The resilience to key-exposure is proved using the CDH assumption. Compared to the existing Identity-based multicloud schemes, it is efficient in integrity verification.

흑연 노즐목 내열재의 열화학적 침식 특성 분석 (Analysis on Thermochemical Erosion Properties for Thermal Insulation Materials of Graphite Nozzle Throat)

  • 김영인;이수용
    • 한국항행학회논문지
    • /
    • 제22권2호
    • /
    • pp.90-95
    • /
    • 2018
  • 로켓 (rocket)이란 배출가스를 빠르게 분사하여 그 반작용의 힘으로 추진력을 발생시키는 추진 장치이다. 그리고 고체추진 로켓 (solid rocket motor)의 구조에서 노즐(nozzle)은 추력을 발생시키는 중요한 구성품으로 고온/고압 환경으로 인하여 연소되며 액체로켓 (liquid rocket propulsion systems)과 다르게 노즐을 냉각시킬 수 없어 연소가스에 의해 침식 (erosion)이 발생한다. 본 논문은 oxy-acetylene torch tester를 개발 및 이용하여 흑연 (graphite) 재질의 노즐목 (nozzle throat) 내열재에 대하여 열화학적 침식 특성을 실험 및 이론적 모델로 규명하고 이를 통하여 침식에 영향을 미치는 주요 인자에 대하여 연구하였다.

A Fast Sorting Strategy Based on a Two-way Merge Sort for Balancing the Capacitor Voltages in Modular Multilevel Converters

  • Zhao, Fangzhou;Xiao, Guochun;Liu, Min;Yang, Daoshu
    • Journal of Power Electronics
    • /
    • 제17권2호
    • /
    • pp.346-357
    • /
    • 2017
  • The Modular Multilevel Converter (MMC) is particularly attractive for medium and high power applications such as High-Voltage Direct Current (HVDC) systems. In order to reach a high voltage, the number of cascaded submodules (SMs) is generally very large. Thus, in the applications with hundreds or even thousands of SMs such as MMC-HVDCs, the sorting algorithm of the conventional voltage balancing strategy is extremely slow. This complicates the controller design and increases the hardware cost tremendously. This paper presents a Two-Way Merge Sort (TWMS) strategy based on the prediction of the capacitor voltages under ideal conditions. It also proposes an innovative Insertion Sort Correction for the TWMS (ISC-TWMS) to solve issues in practical engineering under non-ideal conditions. The proposed sorting methods are combined with the features of the MMC-HVDC control strategy, which significantly accelerates the sorting process and reduces the implementation efforts. In comparison with the commonly used quicksort algorithm, it saves at least two-thirds of the sorting execution time in one arm with 100 SMs, and saves more with a higher number of SMs. A 501-level MMC-HVDC simulation model in PSCAD/EMTDC has been built to verify the validity of the proposed strategies. The fast speed and high efficiency of the algorithms are demonstrated by experiments with a DSP controller (TMS320F28335).

6.6 kV 케이블의 절연저항 측정을 위한 부하전류 및 온도 측정 (Load Current and Temperature Measurement for Measuring the Insulation Resistance of the 6.6 kV Cable)

  • 박용규;조영식;이관우;엄기홍;박대희
    • 한국전기전자재료학회논문지
    • /
    • 제28권1호
    • /
    • pp.46-50
    • /
    • 2015
  • The cable degradation process is largely divided into three steps; Step 1 : Thermal degradation, Step 2 : Weibull degradation, Step 3 : Partial discharge. it is progress in step order. This article aims to explain the process of cable degradation using the method of insulation resistance and accordingly to compose and manufacture a system of measuring the life of electrical cable. Before measuring the insulation resistance, a system of measuring the temperature and current of cables was made, and the established system was installed for test on the site of a power plant to collect the measured data. The current sensor was used TFC30P80A-CL420, and temperature sensor was used the DK-1270 PT100 sensor as RTD sensor. When measured the temperature and the load current at the same position, was confirmed that in case of the load current value was high, also temperature value high. Therefore, the correlation between load currents and temperature was verified, and the analysis of diagnostic data was evaluated, which could be utilized in identifying the fault condition of cable systems.