• 제목/요약/키워드: Insulation systems

검색결과 416건 처리시간 0.025초

Comparison of Conventional DC-DC Converter and a Family of Diode-Assisted DC-DC Converter in Renewable Energy Applications

  • Zhang, Yan;Liu, Jinjun;Ma, Xiaolong;Feng, Junjie
    • Journal of Power Electronics
    • /
    • 제14권2호
    • /
    • pp.203-216
    • /
    • 2014
  • In the conventional dc-dc converter, a pair of additional diode and the adjacent passive component capacitor/inductor can be added to the circuit with an X-shape connection, which generates a family of new topologies. The novel circuits, also called diode-assisted dc-dc converter, enhance the voltage boost/buck capability and have a great potential for high step-up/step-down power conversions. This paper mainly investigates and compares conventional dc-dc converter and diode-assisted dc-dc converter in wide range power conversion from the aspects of silicon devices, passive components requirements, electro-magnetic interference (EMI) and efficiency. Then, a comprehensive comparison example of a high step-up power conversion system was carried out. The two kinds of boost dc-dc converters operate under the same operation conditions. Mathematical analysis and experiment results verify that diode-assisted dc-dc converters are very promising for simultaneous high efficiency and high step-up/step-down power conversion in distributed power supply systems.

A Fast-Transient Repetitive Control Strategy for Programmable Harmonic Current Source

  • Lei, Wanjun;Nie, Cheng;Chen, Mingfeng;Wang, Huajia;Wang, Yue
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.172-180
    • /
    • 2017
  • The repetitive control (RC) strategy is widely used in AC power systems because of its high performance in tracking period signal and suppressing steady-state error. However, the dynamic response of RC is determined by the fundamental period delay $T_0$ existing in the internal model. In the current study, a ($nk{\pm}i$)-order harmonic RC structure is proposed to improve dynamic performance. The proposed structure has less data memory and can improve the tracking speed by n/2 times. $T_0$ proves the effectiveness of the ($nk{\pm}i$)-order RC strategy. The simulation and experiments of ($6k{\pm}1$)-order and ($4k{\pm}1$)-order RC strategy used in the voltage source inverter is conducted in this study to control the harmonic current source, which shows the validity and advantages of the proposed structure.

중온형 원통다관형 수증기 개질기의 부분단열 및 반경방향 분배 구조의 영향 (Partial Insulation and Heating Tubes Configuration of Shell and Tube Steam Reformer at Medium Temperature)

  • 박다인;유상석
    • 한국수소및신에너지학회논문집
    • /
    • 제28권6호
    • /
    • pp.618-626
    • /
    • 2017
  • Conventional high temperature reformers are not suitable for hybrid fuel cell systems that use waste heat as a heat source. So, development of a low temperature type reformer is needed. However, the analysis was conducted in two ways to increase the thermal efficiency, because of low reforming rate due to the low heat source. First, it is a way to ger thermal gain from the outside through partial insulation. In the case of one heat source tube and several heat source tubes, we analyzed the effect of partial heat insulation in some cases. Second, we found the most efficient arrangement of the heat source tubes by changing the location of the heat source tubes. The interpretation was carred out using the COMSOL Mutiphysics program.

고온초전도 시스템 냉각용 고화질소의 기초 절연 특성 (The Basic Insulation Characteristics of Solid-Nitrogen for Cryocooling of HTS Systems)

  • 최재형;최진욱;이해근;송정빈;김해종;성기철;김상현
    • 전기학회논문지
    • /
    • 제58권1호
    • /
    • pp.132-136
    • /
    • 2009
  • Recently, for improvement of the magnetic field of high temperature superconductor (HTS) apparatus, many studies investigating on operating in the range of $20{\sim}65\;K$ with liquid helium or the conducting method using cryocooler are actively reviewed. Also, the cooling method using solid nitrogen as cryogen is being suggested. Since the nitrogen has very large specific heat in solid state, it is expected that it can be operated for a long time without a continuous supply of cooling energy. However, there are still insufficient data on the characteristics of solid nitrogen such as thermodynamic properties and liquid-solid phase change. Especially, there was almost no study done on the electrical insulation properties of solid nitrogen so far. In this study, solid nitrogen to find the electrical characteristics was made by using cryocooler and cryostat, and investigated the flashover discharge and breakdown. The results of this study will be useful as a basic data for electrical insulation design of the HTS system using solid nitrogen as cryogen.

수정 Berggren 법과 수치해석법에 의한 동결깊이 산정 비교 (Comparison of Modified Berggren Method with Numerical Method for the Frost Penetration Depth)

  • 김광진;김영진;이대영;이하영
    • 한국지반환경공학회 논문집
    • /
    • 제14권6호
    • /
    • pp.21-29
    • /
    • 2013
  • 본 논문은 수정 Berggren 법과 상전이 현상을 모델링할 수 있는 유한요소 수치해석법을 사용하여 단열재를 포함한 대표적인 다층 지반에 대하여 동결깊이를 산정하여 비교 분석하였다. 균일한 단층 지반에서 수정 Berggren 법은 유한요소 수치해석법과 거의 동일한 결과를 보여주고 있다. 그러나 단열재를 포함한 다층 지반에서 수정 Berggren 법은 유한요소 수치해석 결과와 비교할 때 정확하지 않은 결과를 나타내고 있다. 따라서 단열재를 포함한 다층 지반에서는 수정 Berggren 법 대신에 유한요소나 유한차분법에 기반을 둔 수치해석법을 사용하여 동결깊이를 산정하여야 할 것으로 사료된다.

유중 부분방전의 음향검출에 관한 연구 (A Study on the Acoustic Detection of Partial Discharges in Insulation Oil)

  • 길경석;김성욱;박대원;김선재;송재만
    • 한국전기전자재료학회논문지
    • /
    • 제23권1호
    • /
    • pp.53-60
    • /
    • 2010
  • This paper dealt with the acoustic detection of partial discharge (PD) in insulation oil for insulation diagnostics of oil immersed transformers. Electrode systems such as needle to plane, plane to plane, and floating were fabricated to simulate some defects in transformers. A wide band acoustic emission(AE) sensor with the frequency ranges of 100 kHz~1 MHz and a narrow band AE sensor with the resonant frequency of 140 kHz were used in the experiment. Also, a decoupler and an amplifier were designed to detect and amplify the acoustic signal only. The decoupler separates acoustic signal from DC source without any distortion, and the amplifier has the gain of 40 dB in frequency ranges of 11 kHz~4 MHz. In the experiment, frequency components and propagation characteristics of acoustic signal were analyzed, and an algorithm of positioning of PD occurrence by the time difference of arrival was proposed. From the results, the frequency components of the acoustic signal exist from 50 kHz to 200 kHz and the positioning error of PD calculated by three AE sensors was within 1%.

인공신경망을 이용한 전기배선의 트랙킹 식별에 관한 연구 (Identification of Tracking Conduct Wiring Using Neural Networks)

  • 최태원;이오걸;김이곤
    • 한국지능시스템학회논문지
    • /
    • 제8권2호
    • /
    • pp.1-8
    • /
    • 1998
  • In this paper, a method which cna detect tracking caused by the insulation deterioration of conduct wiring, is proposed. To investigate it, we analyzed the harmonics of each load current waveform and those of tracking current waveform with FFT. The computer which take experiment data is learned by neural network algorithm, which has recently been used for the load recognition. The proposed metod in our study can be applied to the development of several measuring equipments such as hotline insulation tester, cna earch tester for the detection of tracking under hot-line state, Furthermore, it can substitutes molded case circuit breaker, fuse, and so on.

  • PDF

전력용변압기 단선 보호용 NGR 성능 개선 (The Improvement of NGR for Power Transformer Open Circuit Protection)

  • Kang, Y.W.;Shim, E.B.;Kwak, J.S.
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.83-88
    • /
    • 2004
  • As the electric system is getting larger to meet the increasing demand for electric power, the rating of power apparatus is becoming inevitably higher in its working voltage and larger in its capacity. According to KEPCO reports, power transformers in the KEPCO system have undergone troubles such as winding short insulation breakdowns every year since 1981. the cause of this troubles were high one line grounding fault currents in KEPCO systems that had direct grounding systems. KEPCO has installed the NGR(neutral grounding reactor) to lower this fault current and reduced winding short insulation breakdowns in power transformers. But when a circuit breaker opened a no load bus, some trips of circuit breakers for protecting transformer have occurred by mal-operation of 59GT(overvoltage ground relay) that detect disconnection of NGR. Therefore, in this paper, we analyzed the cause and examined the effect of time delav circuit to prevent wrong operation of 59GT.

  • PDF

10 MW 급 초전도 풍력발전기용 고온초전도 레이스트렉 코일의 응력 해석 (Stress analysis of HTS racetrack coils for 10 MW class superconducting wind power generator)

  • 김광민;김경훈;박민원;유인근
    • 한국산업정보학회논문지
    • /
    • 제18권2호
    • /
    • pp.13-18
    • /
    • 2013
  • The authors designed a high temperature superconductor (HTS) racetrack coil for a 10 MW class superconducting synchronous wind turbine generator. The designed HTS racetrack coil was analyzed by an electromagnetic finite element method (FEM) to determine the magnetic field distribution, inductance, stress, etc. This paper describes the stress analysis and structure design result of the HTS racetrack coil for 10 MW class superconducting synchronous wind turbine generators, considering orthotropic material properties, a large magnetic field, and the resulting Lorentz force effect. Insulated HTS racetrack coils and no-insulation HTS racetrack coils were also considered. According to the results of the stress analysis, the no-insulation HTS racetrack coil results were better than the insulated HTS racetrack coil results.

지중송전케이블계통에서 절연통 보호대책 및 과전압 해석 (Protection of Insulation Joint Box and Analysis of Overvoltage in Underground Power Cable Systems)

  • 홍동석;진혜영;정채균;이종범;조한구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.380-382
    • /
    • 2001
  • This paper describes the protection of insulation joint box in combined transmission line which is connected with the 154kV underground power cables. An actual power cable system was selected to establish modeling and to analyze. Modeling was established in EMTP and ATPDraw. Simulation was carried out according to the buried method of cable and connection method of CCPU. Results presented in this paper will be applied to another power cable systems.

  • PDF