• 제목/요약/키워드: Insulation systems

검색결과 416건 처리시간 0.033초

전력케이블 열화진단기법의 현장적용 (Field Application of Power Cable Diagnosis System)

  • 김주용;한재홍;송일근;김상준;이재봉;오재형
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.148-151
    • /
    • 2002
  • In order to prevent the failures of underground distribution power cables we need to measure insulation condition in the field. Until now we used DC high voltage as a power source for the cable diagnosis but it was not proper method to the XLPE insulation cables because DC high voltage can affect sound insulation and can't diagnose exactly insulation degradation. For these reasons we imported isothermal relaxation current measurement system called by KDA-1 from germany but it's reliability did not proved in our URD cables. DC voltage decay measurement system was developed by domestic company but they don't have field experience. In this paper we tried to prove reliability of these two systems in the field. Through the field diagnosis and Ac breakdown test the two systems showed similar results.

  • PDF

절연계의 결함별 부분방전 패턴분석 (Analysis of PD Patterns Depending on Defect Types in Insulation System)

  • 박찬용;김황국;김성욱;지홍근;길경석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.912-918
    • /
    • 2009
  • In this paper, we carried out a comparative analysis of partial discharge(PD) patterns caused by deterioration of cast-resin and oil insulation systems. Various electrode systems were fabricated such as needle-needle, needle-plane and plane-plane to simulate defects that may exist in the insulation system of transformers. A low-noise amplifier which has a gain of 40 dB and a frequency bandwidth of 500 kHz $\sim$ 30 MHz (-3 dB) was designed to detect small PD signals. From the analysis of acquired PD signals, we could find that a unique PD pattern is formed according to types of defect. These data will be applied usefully to diagnose insulation condition of transformers.

  • PDF

IGBT 인버터 구동 저압 유도전동기의 절연특성 연구 (A Study on the Insulation Characteristics of Low-Voltage Induction Motor driven by IGBT PWM Inverter)

  • 황돈하;박도영;김용주;구자윤;박태익;김진홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.206-210
    • /
    • 1999
  • Since the introduction of IGBT PWM inverters, many low-voltage induction motors have been driven by them. Recently, the stator winding insulation failures have attracted much concern due to high dv/dt of IGBT inverter output. In this paper, presented are the detailed insulation test results of 26 low-voltage induction motors. Six different types of insulation techniques are applied to 26 motors. The tests include PD, $tan{\delta}$, and DIV tests. Also, break-down tests by high voltage pulses are performed.

  • PDF

통계처리와 패턴 인식 기법에 의한 부분방전 해석 (Analysis of Partial Discharge Signals Using Statistical and Pattern Recognition Technique)

  • 변두균;홍진웅
    • 제어로봇시스템학회논문지
    • /
    • 제12권12호
    • /
    • pp.1231-1234
    • /
    • 2006
  • In this study, we detected electromagnetic waves generated in an enclosed switchgear and applied various statistical methods for detecting signals. We calculated the various statistical factors via the appropriate statistical methods. Further, we used these statistics to recognize the characteristics for each pattern by identifying the partial discharge in each case for normal, proceeding and abnormal states. The characteristics of electromagnetic wave patterns occurred in various states at electric power facilities and were used as an output variable for more efficient diagnosis. In this paper, we confirmed that the pattern of partial discharge signal can be used as one of the factors used to analyze the insulation state and to consider while estimating diagnosis of insulation states by recognizing the signal pattern to intelligence. We will utilize the proposed diagnosis method to determine insulation degradation states.

공동주택의 단열형태별 선형열관류율 평가 (An Evaluation of the Linear Thermal Transmittance for the Internal Insulation versus the External Insulation in Apartment Housings)

  • 이종성;이도헌;전명훈
    • 토지주택연구
    • /
    • 제5권4호
    • /
    • pp.315-323
    • /
    • 2014
  • 본 연구는 외단열시스템 성능평가의 주요인자인 선형열관류율을 국제규격(ISO)에서 제시하고 있는 평가방법에 의거, 내단열시스템 대비 외단열시스템의 열성능에 대한 우수성을 정량적으로 파악하고, 향후 외단열시스템의 열성능 평가를 위한 기초자료로의 활용을 목적으로 한다. 이를 위해 공동주택의 대표적 열교부위인 3개 부위를 내단열과 외단열 시스템으로 설계하고, 각 부위별 단열형태별로 선형열관류율을 평가하였다. 그 결과, 외벽-발코니 슬라브 부위는 열교차단재 설치가 필수적인 것으로 분석되었으며, 열교차단재를 설치할 경우 외단열시스템이 내단열시스템보다 선형열관류율이 1/2 이상 줄어드는 것으로 나타났다. 측벽-발코니 부위와 같이 슬라브가 외부로 돌출되지 않는 구조에서는 외단열시스템을 적용할 경우, 선형열관류율이 거의 0인 것으로 나타났다. 내단열로 설계된 외벽-경계벽의 경우, 선형열관류율은 0.451W/m 로 내단열로 설계된 외벽-발코니 슬라브 등 열교가 있는 부위와 비슷한 값을 보이며, 외단열로 설치될 경우 이 또한 거의 0인 것으로 나타났다. 향후, 공동주택의 외단열시스템 도입 및 성능평가를 위해서는 국제기준을 적용한 국내 평가기준의 제도화마련이 필요하며, 특히 제도화 마련과정에서 선형열관류율 계산 인자 중의 하나인 벽체길이의 계산방법은 국가차원의 결정이 필요할 것으로 판단된다.

The Analysis Results of Lightning Overvoltages by EMTP for Lightning Protection Design of 500kV Substations

  • Ju Hyung-Jun;Lee Heung-Ho
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권4호
    • /
    • pp.366-370
    • /
    • 2005
  • To meet increasing power demand, 500 kV power systems are under consideration in the regions of some Middle Asian countries. As the power system voltage becomes higher, the cost for the power system insulation increases significantly. 500 kV transmission systems will become the basis of a region's power system and they require much higher system reliability. Consequently, by the methods of limiting overvoltages effectively, a reasonable insulation design and coordination must be accomplished. In particular, the Substations must be constructed to be of outdoor type. In order to determine the various factors for the insulation design, the EMTP (Electro-magnetic transient program) is used for the magnification of transient phenomena of the 500 kV systems in the planned network. In this paper, we will explain the calculation results of lightning overvoltages by the EMTP for lightning protection design for the 500 kV substations. To obtain reliable results, the multi-story tower model and EMTP/TACS model are introduced for the simulation of dynamic arc characteristics.

유한요소법을 이용한 진공인터럽터 절연설계 기초연구 (The Basic Study on the Insulation Design of Vacuum Interrupter using Finite Element Method)

  • 박치영;안희일;함길호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1635-1637
    • /
    • 1998
  • This paper describes on the basic study for the insulation design of vacuum interrupter using Finite Element Method. For the basic study of insulation design, first, the maximum electric field was calculated on each curvature radius of arc shield and electrode. Second, the maximum electric field was also calculated on applied voltage and end shield with or not. Thus, the maximum electric field calculated have an effect on curvature radius and voltage polarity.

  • PDF

Detailed Study on Insulation Coordination of a 25kV Power System Connected with a VCB and Transformer

  • Baek, Byung-San;Kim, Yong-Han
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권3호
    • /
    • pp.1245-1249
    • /
    • 2017
  • Recently, unusual transformer failures have been reported in 25kV power systems connected with a VCB and transformer. In this study, performance of the protection system, dielectric strength of the transformers, characteristics of switching surges and resonance phenomena were analysed and assessed. All investigations regarding the insulation breakdown of the transformers were carried out by simulations, laboratory tests, factory tests and on-site measurements in order to thoroughly investigate the root causes. Furthermore, experimental methods for investigating the resonance phenomenon were derived and tests were conducted applying the derived method to recreate the phenomenon in the transformer. It is found that resonance between the transformer and switching surge generated by closing a VCB can initiate the breakdown of internal windings of a transformer.

금속 이물질이 에폭시 절연물의 절연파괴에 미치는 영향 (Effects of Metal Particle on Dielectric Breakdown of Epoxy Insulation)

  • 장윤기;이동원;김정배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.207-208
    • /
    • 2007
  • Epoxy resin insulators show a lot of advantages for electrical power apparatus. Because epoxy resin provide electrical and mechanical characteristic which is excellent, it is desirable to apply epoxy resin as a spacer and post insulation in Gas Insulated Switchgear (GIS). In this study, we have investigated the influence of surface electric field attached particle contaminated spacer surfaces under SF6 gas. Also, we performed analysis of electric field. As a result, when the particle was attached on spacer, we found out a surface electric field of characteristics.

  • PDF

과도서지를 이용한 가속열화 시험법에 따른 견인전동기 고정자 코일의 전기적 특성 변화 (Properties of Electrical Performance on Stator Coil of Traction Motor by Accelerated lest using Transient Surge)

  • 박현준;장동욱;이길헌;최종선;김저우
    • 한국전기전자재료학회논문지
    • /
    • 제16권9호
    • /
    • pp.783-789
    • /
    • 2003
  • The winding problems of traction motor are the major determinant of motor's life. The root cause of winding failure is gradual deterioration of the insulation due to thermal, electrical, mechanical and environmental stresses. The aging of the insulation reduces the electrical and mechanical strength of the insulation. At same point, a voltage surge or mechanical shock from a traction motor start will fracture or break down the insulation. To achieve the expected life usually requires extensive laboratory evaluation of the insulation systems and the use of accelerated aging tests. There are several nondestructive test available for checking, the condition of motor insulation, the probable extent of aging, and the rate of which aging is taking place. So the insulation characteristics of stator coil were each analyzed by measurement of dielectric loss(tan$\sigma$), capacitance and partial discharge. The method of diagnosis is able to analyze the insulation condition and evaluate the life of the traction motor.