• Title/Summary/Keyword: Insulation standard

Search Result 311, Processing Time 0.026 seconds

Defect detection of vacuum insulation panel using image analysis based on corner feature detection (코너 특정점 기반의 영상분석을 활용한 진공단열재 결함 검출)

  • Kim, Beom-Soo;Yang, Jeonghyeon;Kim, Yeonwon
    • Journal of the Korean institute of surface engineering
    • /
    • v.55 no.6
    • /
    • pp.398-402
    • /
    • 2022
  • Vacuum Insulation Panel (VIP) is an high energy efficient insulation system that facilitate slim but high insulation performance, based on based on a porous core material evacuated and encapsulated in a multi-barrier envelope. Although VIP has been on the market for decades now, it wasn't until recently that efforts have been initiated to propose a standard on aging testing. One of the issues regarding VIP is its durability and aging due to pressure and moisture dependent increase of the initial low thermal conductivity with time. It is hard to visually determine at an early stage. Recently, a method of analyzing the damage on the a material surface by applying image processing technology has been widely used. These techniques provide fast and accurate data with a non-destructive way. In this study, the surface VIP images were analyzed using the Harris corner detection algorithm. As a result, 171,333 corner points in the normal packaging were detected, whereas 32,895 of the defective packaging, which were less than the normal packaging. were detected. These results are considered to provide meaningful information for the determination of VIP condition.

Review of Measurement of Sound Insulation in Buildings and of Building Elements Using Sound Intensity : Laboratory Conditions (Sound Intensity를 이용한 건물부재의 차음성능 실험실 측정방법 고찰)

  • Jung, Sung-Soo;Kook, Chan;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.1138-1141
    • /
    • 2002
  • In this study, the ISO 15186-1 “Measurement of sound insulation in buildings and of building elements using sound intensity - Part 1 : Laboratory conditions” was reviewed in order to make it as a new Korean Industrial Standard. Several main contents are discussed.

  • PDF

A preliminary study on the measurement method for determining the absorption coefficient of sound barrier panels (방음판의 흡음률 측정방법 제안을 위한 기초 연구)

  • Yang Ki Oh;Ha Geun Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.2
    • /
    • pp.152-160
    • /
    • 2023
  • Sound barrier walls are the most basic way to cope with noise problems in urban residential environments. The most important acoustic function of sound insulation board is represented by sound transmission loss and sound absorption coefficient. However, Korea has not yet established a standard for measuring the sound absorption rate of sound insulation boards. In addition, even in the European standard, where the overall acoustic standard of soundproofing boards has already been established, the sound absorption rate is applied only to the standard for measuring the sound absorption rate of general building finishing materials, and a separate measurement method considering the characteristics of soundproof walls and soundproofing boards is not presented. The sound absorption coefficient should be evaluated by summing up the energy absorbed into the material as well as the energy transmitted through the material, but the current European standard has a problem in that the transmitted sound energy is not taken into account. In this paper, we reviewed the sound absorption coefficient measurement standards of sound insulation boards currently being presented, and verified the difference between the results and the new measurement method considering transmission sound for sound insulation boards actually used in Korea.

An Evaluation of the Linear Thermal Transmittance for the Internal Insulation versus the External Insulation in Apartment Housings (공동주택의 단열형태별 선형열관류율 평가)

  • Lee, Jong-Sung;Lee, Do-Heun;Jun, Myoung-Hoon
    • Land and Housing Review
    • /
    • v.5 no.4
    • /
    • pp.315-323
    • /
    • 2014
  • In this study, thermal transmittance which is a parameter to measure the thermal performance was evaluated for an internal insulation versus an external insulation. Then the ISO regulation was applied to evaluate it, and the superiority of an external insulation was verified by the thermal transmittance values. The three zones of apartment housing were selected to evaluate the performance. (1) The junction of an outer wall and a protruded slab : If there is no a thermal bridge protection system, then the values are about same in the two insulation systems, so the protection system should certainly be installed. If it is installed, then the value for the external insulation is 2 times lower than internal system. (2) The junction of a side wall and a flat slab: The value is 0.509W/mK for the internal insulation and about zero for the external insulation. (3) The junction of an outer wall and a division wall: The value is 0.451W/mK for the internal insulation and also about zero for the external insulation. A domestic regulation that could evaluate a thermal transmittance has to be established by applying the ISO regulation for the evaluation of external insulation systems in apartment housing in the future. Additionally, the government must decide which length should be used for the national standard.

Thermal Insulation and Flame Retardant Properties of Cement Based Super Light-weight Inorganic Thermal Insulation using 100㎛ Grade Glass Bubble (100㎛급 글라스 버블 혼입 시멘트계 초경량 무기 단열재의 단열 및 난연특성)

  • Son, Bae-Geun;Song, Hun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.4
    • /
    • pp.642-649
    • /
    • 2021
  • Energy saving standard for buildings are strengthened, the application of exterior insulation finishing system and thickness of insulation materials are increasing. Most buildings with exterior insulation finishing system is applied organic insulating material. Organic insulating material have workability, economic feasibility, reduction in construction cost, and excellent thermal insulation performance. However, Organic insulating material is very vulnerable to heat, so when a fire occurs, rapid fire spread and toxic gas are generated, causing many casualties. Inorganic insulating material can be non-combustible performance, but it is heavy and has low thermal insulation performance. Mineral wool has higher thermal insulation performance than other types of inorganic insulating material, but mineral wool is disadvantageous to workability and vulnerable to moisture. Glass bubble are highly resistant to water and chemically stable substances. In addition, the density of the glass bubble is very low and the particles are spherical, fluidity is improved by the ball bearing effect. Glass bubbles can be used with cement-based ino rganic insulating material to impro ve the weight and thermal insulatio n perfo rmance o f cement-based inorganic insulation. This study produced a inorganic insulating materials were manufactured using cement-based materials and glass bubble. In order to evaluate the insulation performance and flame retardant performance of cement-based super light-weight inorganic insulating materials using with glass bubble, insulation performance or flame retardant and non-combustible performance were evaluated after manufacturing insulating materials using micro cement and two types of glass bubbles. From the test result, Increasing the mixing ratio of glass bubbles improved the insulation performance of cement-based super light-weight inorganic insulating materials, and when the mixing ratio of glass bubbles was 10%, it sho wed sufficient flame retardant and no n-co mbustible perfo rmance.

Korean Standard Draft of the Laboratory Method of Measuring the Airborne Sound Insulation of a Suspended Ceiling (매단 천장의 실간 공기전달음 차단성능 측정방법의 KS규격화 방안)

  • Yang, Kwan-seop;Lee, Keun-hee;Kim, Sun-woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.393.1-393
    • /
    • 2002
  • Offices and other multipurpose buildings commonly have suspended ceilings installed over room dividing wall. But Korean Standards don't include any code on test methods and test facility of the suspended ceiling system. Therefore, test methods and test facility from ISO and ASTM have been used for evaluating sound performance in domestic so far. In this study, Korean Standards draft on test methods and test facility of suspended ceiling system and materials is proposed on the basis of ISO and ASTM.

  • PDF

Heat Insulation Properties of Lightweight Magnesia Matrix According to Mixing Ratio of Anthracite (안트라사이트 치환율에 따른 경소마그네시아 경화체의 단열특성)

  • Pyeon, Su-jeong;Gwon, Oh-han;Kyoung, In-soo;Lee, Dong-hoon;Lee, Sang-soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.113-114
    • /
    • 2017
  • Recently, Subway workers have died from lung cancer. According to the Epidemiological Survey of the Welfare Corporation Institute of Pulmonary Disease of the Welfare Corporation, the family members applied for industrial accidents. The radon concentration in the subway work area was found to exceed 10 times the recommended standard value of 148 becquerels (Bq/㎥) in domestic multipurpose facilities. In addition, as a result of the national indoor radon concentration survey conducted by the Ministry of Environment in 2010 and 2013, housing was found to be over 100 becquerels (Bq/㎥) in 41% of the surveyed subjects. In addition, it was found that in 2012, 16.3% of villages exceeded the radon standard value in the survey on natural radioactive materials containing groundwater.

  • PDF

A "Fabric-First" Approach to Sustainable Tall Building Design

  • Oldfield, Philip
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.2
    • /
    • pp.177-185
    • /
    • 2017
  • This research suggests the most effective way for improving energy efficiency in tall buildings is a "fabric-first" approach. This involves optimizing the performance of the building form and envelope as a first priority, with additional technologies a secondary consideration. The paper explores a specific fabric-first energy standard known as "Passivhaus". Buildings that meet this standard typically use 75% less heating and cooling. The results show tall buildings have an intrinsic advantage in achieving Passivhaus performance, as compared to low-rise buildings, due to their compact form, minimizing heat loss. This means high-rises can meet Passivhaus energy standards with double-glazing and moderate levels of insulation, as compared to other typologies where triple-glazing and super-insulation are commonplace. However, the author also suggests that designers need to develop strategies to minimize overheating in Passivhaus high-rises, and reduce the quantity of glazing typical in high-rise residential buildings, to improve their energy efficiency.

Accelerated Life Test and Data Analysis of the Silver Through Hole Printed Wiring Board (가속수명시험을 이용한 은도통홀 인쇄회로기판의 신뢰성연구)

  • 전영호;권이장
    • Journal of Korean Society for Quality Management
    • /
    • v.25 no.2
    • /
    • pp.15-27
    • /
    • 1997
  • This paper describes a highly accelerated life test (HALT, USPCBT) method for rapid qualification testing of STH PWB(Silver Through Hole Printed Wiring Boards). This method was carried out to be an alternative to the present time-consuming standard 1344 hours life testing(THB). The accelerated life test conditions were $121^{\circ}C$/95%R.H. at 50V bias and without bias. Their results are compared with those observed in the standard 1344 hours life test at $40^{\circ}C$/95%R.H. at 50V bias and without bias. The studies were focused on the samples time-to-failure as well as the associated conduction and failure mechanisms. The abrupt drop of insulation resistance is due to the absorption of water vapour. And the continuous drop of insulation resistance is due to the Ag migration. The ratios of time-to-failure of HALT(USPCBT) to THB were 25 and 11 at 50V bias and without bias respectively.

  • PDF

An experimental study on the fireproof performance of fire damper in accordance with insulation conditions on the coaming and blade (코밍 방열 두께 및 블레이드 방열 유무에 따른 방화 댐퍼의 내화성능에 관한 실험적 연구)

  • Choi, Tai-Jin;Kim, Joung-Sik;Choi, Kyeong-Kwan;Lim, Young-Soo;Kim, You-Taek
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.431-437
    • /
    • 2013
  • In this paper, Fire resistance test was carried out to obtain class H-120 thermal insulation of fire dampers according to a hydrocarbon fire conditions. Specimens were fabricated three different types according to the change of the insulation system applied to damper blade and coaming which were measured surface temperature by performing the fire resistance test. As a test result, specimen-1, 2 of an uninsulated damper blade were exceeded thermal insulation acceptance criteria at 21 minutes, 46 minutes respectively, but specimen-3 of an insulated damper blade was satisfied thermal insulation acceptance criteria during 120 minutes. The test results showed that the insulation of the damper blade is an important factor in the fireproof performance of fire dampers concerning the coaming length minimum 500 mm on the unexposed side as specified test standard.