• Title/Summary/Keyword: Insulation method

Search Result 1,169, Processing Time 0.036 seconds

Examined of reinforcement for the fire protection of the outside insulation Urbantype Housing with flammable insulation material (가연성 단열재를 사용한 외단열 도시형 생활주택의 방화를 위한 보강재 검토)

  • Lee, Kwang-Hee;Jung, Ui-In;Kim, Bong-Joo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.28-29
    • /
    • 2015
  • Due to the big fire in Uijeongbu, the status of construction, fireproof materials and structural method were examined to prevent fire propagation through outside insulation parts of urban living homes. Through research and experiments, the following results were obtained. It was confirmed that outside heat-insulation wall method was used in a large number of urban living homes which were made of materials and structures spreading fire easily.Through experiments, it was revealed that lightweight plate material, as a fireproof material, can save the cost as well as the period of construction and obtain more than 30 minutes of evacuation time which is twice the maximum evacuation time.

  • PDF

Development of Insulation Degradation Diagnosis System for Electrical Plant

  • Kim, Yi-Gon
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.2 no.1
    • /
    • pp.33-37
    • /
    • 2002
  • Insulation aging diagnosis system provides early warning regarding electrical equipment defects. Early warning is very important in that it can avoid great losses resulting from unexpected shutdown of the production line. Since relations of insulation aging and partial discharge dynamics are non-linear. it is very difficult to provide early warning in an electrical equipment. In this paper, we propose the design method of insulation aging diagnosis system that use a electromagnetic wave and acoustic signal to diagnose an electrical equipment. Proposed system measures the partial discharge on-line from DAS(Data Acquisition System and acquires 2D patterns from analyzing it. For filtering the noise contained in sensor signals we used ICA algorithms. Using this data, we design of the neuro-fuzzy model that diagnoses an electrical equipment and is investigated in this paper. Validity of the new method is asserted by numerical simulation.

An Experimental Study on Evaluation of the Sound Insulation for Balcony Window in Apartment Houses (공동주택 발코니 창호의 차음성능 평가에 관한 실험적 연구)

  • 김하근
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.11
    • /
    • pp.1137-1146
    • /
    • 2004
  • In an apartment house In Korea, the balcony is one of the important spaces as a buffer zone for controlling the outdoor environments such as noise, heating & cooling load, humidity etc. Because most areas of building facade in apartment building occupy the area of balcony window the sound Insulation design of It Is very Important to provide the quiet indoor environment. The aim of this research is to evaluate the sound insulation of balcony windows in apartment building by new and revised Korean Industrial Standards. We measured and studied the sound insulations of 18 balcony windows by the type of measuring methods, noise sources, correction of reverberation time in balcony and so on. The results show that the single-number quantities for sound insulation of windows are ranged from 24 dB to 30 dB.

A study on the optimal design for heat insulation of hot water piping systems using a dynamic programming (동적계획법을 이용한 고온수배관의 최적보온설계에 관한 연구)

  • 유희한;하주식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.39-52
    • /
    • 1987
  • Recently, the design problem of heat insulation have been reappraised in the aspect of energy saving due to the rising trend of energy cost. For example, that design problem is increasingly requsted in the fields of accommodation air conditioning systems, hot water supply systems, cargo handling systems, district heating or cooling systems. The rational design of heat insulation of piping systems can not only improve the overall efficiency of energy transfer but also give energy saving. In this paper, the heat insulation problem of district heating systems is therefore modeled as the multi-stage decision processes, suitable for dynamic programming technique. And take the object function as the sum of heat insulation material cost involved construction cost and heat loss cost, and propose the design method to minimize the object function for overall piping systems by dynamic programing. Effectiveness of design method presented here is proved by a computer simulation.

  • PDF

Characteristic of Vibration and Sound of Sound Insulation Panel for Transformer (변압기용 차음판의 진동 및 소음 특성)

  • Choe, C.R.;Choi, B.K.;Yang, B.S.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.255-258
    • /
    • 2005
  • Recently, demands for the reduction of noise generated by transformers have been increasing. Almost all the noise generated by a transformer is a result of magnetostrictive vibration in the core. The noise radiates into the atmosphere from the tank through the insulation oil. One method of reduction such a noise is to build a free-standing enclosure of concrete and steel plates around the transformer. However, this method has some disadvantages, for example, a large area is needed for equipment installation. In this paper, the vibration and noise effects which is transferred from reinforce channel to insulation panel generated by transformer have been identified for the several kinds of insulation panel shape and damping sheet experimentally.

  • PDF

Shear Performance Evaluation of Composite Thermal Insulation with Quasi-Non-Combustible according to Adhesive Type (부착 유형에 따른 준불연 복합단열판 전단성능평가)

  • Choi, Ki-Sun;Oh, Keunyeong;Park, Keum-Sung;Ha, Soo-Kyung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.5
    • /
    • pp.507-518
    • /
    • 2022
  • The purpose of this research is to obtain experimental data for developing a structural design of an external insulation system by evaluating the shear performance of a composite insulation system according to the adhesive type. The shear performance of the composite insulation system was experimentally evaluated by considering a simultaneous placement method, full and spot/edge coverage using adhesive mortar. As a result of the test, the shear strength of simultaneous placement and full coverage method was almost similar, the spot/edge coverage method was about 80% of them. Also, the simultaneous placement method is considered to be constructively advantageous when applied as an external insulation system to a high-rise building compared to using an adhesive mortar.

Changes in Insulation Performance of Organic Insulating Materials for Building Construction by Accelerated Durability Test Conditions (가속내구성 조건에 따른 건축용 유기계 단열재의 단열성능 변화)

  • Lim, Soon-Hyun;Lee, Gun-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.6
    • /
    • pp.595-601
    • /
    • 2016
  • The insulation performance of the insulation currently used in building structures is reflected only during design based on initial performance and the reduction in heat insulation performance due to the degradation of long-term durability is not reflected. This study reviewed the degradation of heat insulation performance due to the durability degradation of insulating materials through the accelerated durability test. The study findings showed that the foamed polystyrene insulation bead method did not show performance degradation due to aging in the standard environmental condition and laboratory accelerated test condition but the performance is degraded in the freeze-thaw test condition. On the other hand, in the case of the extrusion method, the degradation of the heat insulation performance was less in the freeze-thaw test condition, but the rapid performance degradation was caused by the release of the internal gas at the beginning of aging. In addition, the hard polyurethane foam insulation showed better initial insulation performance than other insulation materials, but the performance was found to be degraded somewhat under laboratory accelerated test conditions and freeze-thaw test conditions.

Studies on Insulation Effect Related with Thin-Plate Design Factors for Reflective Metal Insulation(RMI) of Nuclear Power Plant (금속단열재 박판의 설계인자별 단열성능 영향 연구)

  • Eo, Minhun;Lee, Sungmyung;Jang, Kyehwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.9
    • /
    • pp.350-354
    • /
    • 2016
  • Although fibrous insulations are generally used with resistive insulation type, metallic insulation is proper matter to satisfy low head-loss and equipment life when considering the specific condition, especially for Nuclear power plant. Common insulation is resistance insulation with a low thermal conductivity. but RMI is made of sheet plate with low emissivity and closed air space. Thermal radiation is blocked by stainless steel with low emissivity. Thermal conductivity and thermal convection are blocked by closed air space. This study shows the changes and effects of the heat loss according to shape and method of stacking sheet plates inserted into the insulation and analyzed the most optimized way for thermal insulation performance. The result shows that using sheet plate structure through raised and protruding shape processing was the appropriate model to optimize thermal performance. Additionally, insulating performance of RMI improved by placing the sheet plate in a high temperature region intensively.

Design of Insulation and Bending Test for a 154 kV Class HTS Cable (154 kV급 HTS 케이블의 절연설계 및 굴곡시험)

  • Choi, Jin-Wook;Choi, Jae-Hyeong;Lim, Eung-Choon;Kim, Hae-Jong;Cho, Jeon-Wook;Kim, Sang-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.11
    • /
    • pp.1024-1028
    • /
    • 2008
  • It is important that study on cryogenic electrical insulation design to develop the cold dielectric(CD) type HTS cable because the cable is operated under the high voltage environment in cryogenic temperature. This paper proposes two types of insulation design to carry out the maximum insulation design for 154 kV-class HT cable. The proposed insulation design method takes into consideration AC and lightning impulse withstand voltage so as to prevent AC breakdown for power frequency operating voltage during operating the cable and breakdown for lightning impulse voltage. The final insulation thickness is determined by selecting high value out of two insulation thickness calculated through the two insulation design methods. And we researched electrical insulation characteristics of HTS cable according to bending ratio and the number of bending.

The Control of Temperature of Green Roof System with the Roof Slab Insulation Method (옥상슬래브 단열조건에 따른 옥상녹화의 열환경 조정효과)

  • Yeo, In-Ae;Cho, Hong-Je;Yoon, Seong-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.869-872
    • /
    • 2008
  • On this study, the Control of Temperature is specified on the view of indoor comfort and building energy consumption. It is estimated by Dynamic heat load simulation which has the factors of insulation method and the soil thickness of the green roof system. The fact that the model which has no insulation has the greatest effect of dropping high temperature and the cooling load decrease is confirmed.

  • PDF