• Title/Summary/Keyword: Insulation life

Search Result 285, Processing Time 0.024 seconds

Development of Improvement Technology of Sound Insulation Performance of Unitex Structure (유니텍스 구조의 차음성능 향상기술 개발)

  • Byeon, Jun-Ho;Lee, Joong-Hyeok;Kim, Seockhyun;Lee, Jae-Joon;Ki, Ho-Cheol
    • Transactions of the KSME C: Technology and Education
    • /
    • v.4 no.2
    • /
    • pp.123-130
    • /
    • 2016
  • Unitex is widely used for the floor structure of urban railway vehicles because it shows good structural safety and heat insulation, has long life, and lowers the cost owing to easy installation. However, in spite of these merits, Unitex has a limit to the sound insulation performance, which is very important in vehicle structure. It shows a sound transmission loss considerably lower than the mass law value, which indicates the sound insulation performance per unit weight. Recently, railway vehicle manufacturers and Unitex supplier have tried to improve the sound insulation performance of Unitex, but meaningful results have not been achieved yet. Through the industry-university collaborative research, we propose structural improvement methods to increase the sound transmission loss by more than 5dB and we then verify the effect by performing experiments.

Degradation Diagnosis of Complex System Using Regression Analysis (희귀분석을 이용한 복합 시스템의 열화진단)

  • Kim, Seong-Hong;Song, Jae-Joo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.09a
    • /
    • pp.60-66
    • /
    • 2001
  • Because of internal voids in insulators give rise to partial discharge(PD), which cause local breakdown and even entire insulation breakdown. Treeing due to PD is one of the main causes of breakdown of the insulating materials and reduction of the insulation life. Therefore the necessity for establishing a method to diagnose the aging of insulation materials and to predict the breakdown of insulation has become important. From this viewpoint, our studies diagnose insulation degradation using the method of computer sensing system, which has the advantages of PD and acoustic emission(AE) sensing system. To use advantages of these two methods can be used effectively to search for treeing location and PD in some materials. In analysis method of degradation, We analyzed the PD pulse and AE pulses by regression analysis, compared to these obtained the correlation coefficient and determination coefficient by T-distribution and saw that PD and AE pulses show a similar pattern on the whole. This is in agreement with the results of the research by Yoshimura and Fujita.

  • PDF

A Reliability Evaluation by Regression Analysis of PD and AE Pulse in Low Density Polyethylene (저밀도 폴리에틸렌에 있어서 부분방전과 음향방출펼스 상호간의 회기분석에 의한 신뢰도 평가)

  • Kim, S.H.;Choi, J.K.;Yoon, H.J.;Shim, J.T.;Kim, J.H.;Park, J.J.;Shin, S.J.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1761-1763
    • /
    • 1997
  • Because of internal voids in insulators give rise to partial discharge (PD), which cause local breakdown and even entire insulation breakdown. Treeing due to PD is one of the main causes of breakdown of the insulating materials and reduction of the insulation life. Therefore the necessity for establishing a method to diagnose the aging of insulation materials and to predict the breakdown of insulation has become important. From this viewpoint, our studies diagnose insulation degradation using the method of computer sensing system, which has the advantages of PD and acoustic emission (AE) sensing system. To use advantages of these two methods can be used effectively to search for treeing location and PD in some materials. In analysis method of degradation, We analyzed the PD pulse and AE pulses by regression analysis, compared to these obtained the correlation coefficient and determination coefficient by T-distribution and saw that PD and AE pulses show a similar pattern on the whole. This is in agreement with the results of the research by Yoshimura and Fujita.

  • PDF

Degradation Diagnosis of Complex System Using Regression Analysis (회귀분석을 이용한 복합 시스템의 열화진단)

  • 김성홍;박재준;김재환
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.1
    • /
    • pp.39-45
    • /
    • 1999
  • Because of internal voids in insulators give rise to partial discharge(PD), which cause local breakdown and even entire insulation breakdown. Treeing due to PD is one of the main causes of breakdown of the insulating materials and nrluction of the insulation life. 1berefore the necessity for establishing a rrethod to diagnose the aging of insulation materials and to predict the breakdown of insulation has becorne irrportant. From this viewpoint, our studies diagnose insulation degradation using the rrethod of computer sensing system, which has PD and acoustic emission(AE) sensing system. To use advantages of these two methods can be used effectiveiy to search for treeing location and PD in sorre materials. In analysis rrethod of degradation, we analyzed the PD and AE pulses by regression analysis, corrpared to these obtained the correlation coefficient and retermination coefficient by T-distribution and saw that PD and AE pulses show a similar pattern on the whole. This has a similar teIlrency to the results of the research by Yoshimura and Fujita.Fujita.

  • PDF

Importance of Preliminary Validation of Exterior Wall Thermal Resistance in the Evaluation Context of Building Energy Retrofit Projects (그린리모델링 성과 평가 관점에서 본 준공 시점 단열 성능 검증의 중요성)

  • Seungmin Lim;Soyeon Kim;Changoh Kang;Gain Kim;Jongyeon Lim
    • Land and Housing Review
    • /
    • v.15 no.2
    • /
    • pp.29-37
    • /
    • 2024
  • This study investigates the thermal conductivity and density of expanded polystyrene insulation materials collected from buildings under going energy retrofit projects. Due to the absence of initial thermal conductivity data, determining precise long-term patterns was challenging. Analysis based on design documents revealed that expanded polystyrene insulation maintained consistent performance over ten years. Notably, the thermal conductivity measurements of insulation samples of the same grade and age varied significantly. Additionally, the insulation density was found to be substantially below the standard specified in the design documents. The results of the experiment indicate that performance management during both construction and operation phases is lacking. It is crucial to apply building commissioning, which involves performance verification throughout the building's life cycle, to properly evaluate building energy performance improvements, such as building energy retrofit projects.

Electrical Life Time Constant Estimation of Ceramic Element for Sensor (센서용 세라믹 소체의 전기적 수명지수 산출)

  • Jeong, Joo-Young;Kang, Dong-Sik;Sun, Jong-Ho;Heo, Jong-Cheol;Choo, Young-Bae;Park, Chung-Hoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1995-1999
    • /
    • 2009
  • A partial discharge(PD) measurement is a very effective method to assess the insulation condition of high-voltage machines. It is necessary that the life time of the on-line PD measurement sensor is assessed. Therefore, the electrical life time assessment method of ceramic element was reviewed in order to estimate the life time of the on-line PD measurement sensor. The samples were prepared according to the reviewed method and were tested at 8kV, 9kV and 10kV. Based on the obtained results, the life time constant is shown above 59. Also, it is assumed that the estimated life time constant can be used to anticipate the life time and to assess the conformity of the on-line PD measurement sensor.

A LIFE PREDICTION OF LDPE DEGRADATION PROCESSING USING PARAMETERS (파라미터를 이용한 LDPE 절연열화 과정의 수면예측)

  • Kim, Sung-Hong;Seo, Jang-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07e
    • /
    • pp.40-43
    • /
    • 2000
  • Our studies diagnose insulation degradation using the method of computer sensing system, which has the advantages of PD(partial discharge) and AE(acoustic emission) sensing system. To use advantages of these two methods can be used effectively to search for treeing location and PD in some materials. In analysis method of degradation, using statically operator such as the center of gravity (G), the gradient of the discharge distribution(C), we have analyzed for the prediction of life which we can be obtained the time, occurred of many pulse of small discharge amplitude.

  • PDF

Relationship of Ceramic Insulation Panel System Development and Verification of LCC

  • Han, Min-Cheol;Jeon, Kyu-Nam;Lee, Gun-Cheol;Kim, Tae-Hui
    • Journal of the Korea Institute of Building Construction
    • /
    • v.12 no.4
    • /
    • pp.386-392
    • /
    • 2012
  • In this study, life cycle cost (LCC) is analyzed according to insulation panel system type using a deterministic LCC analysis method. Through this analysis, it was found that the construction cost in the deterministic LCC analysis for Ceramic panels was low compared to the construction cost for metal and stone panels. Also, the difference in cost between the Ceramic panel and the metal panel was about 2 times. In the area of maintenance cost, it was found to be similar to the previously analyzed construction cost, in which the metal panel has the highest cost due to the high cost of construction and the frequent need for maintenance. In the case of the stone panel, a small difference in cost is shown compared with that of the Ceramic panel, but the cost is higher than the Ceramic panel. Regarding the cost of waste disposal, the Ceramic panel can reduce the cost by at least 1.5 times and up to 2 times compared to other panel systems. Finally, in the analysis of sensitivity according to changes in discount rates, the Ceramic panel and metal panel systems have a similar cost, and the cost of the metal panel is a bit larger than that of other panel systems. Thus, in the subjects used in the analysis, the Ceramic panel system shows the highest economic benefits.

Feature Extraction of Partial Discharge for Stator Winding of High Voltage Motor (고압전동기 고정자권선의 부분방전 특징추출)

  • Park, Jae-Jun
    • The Journal of Information Technology
    • /
    • v.7 no.4
    • /
    • pp.61-69
    • /
    • 2004
  • On-line monitoring of fault discharge is an important approach for indicating the condition of electrical insulation of stator winding in high voltage motor. In this paper, several key aspects of on-line monitoring system are discussed, involving the characteristics of fault discharge of stator winding in high voltage motor, spectrum analysis of four simulation fault signals, feature extraction of internal fault discharge from apply voltage to breakdown. The study of the partial discharge activities allows to highlight the ageing stage in the winding fault under test. During the life of the winding insulation fault, the shape of PD signal change relating to the ageing stage. The ageing of stator winding insulation fault of high voltage motor is investigated based on the characteristics of partial discharge pulse distribution and statistical parameters, such as maximum, skewness and kurtosis using discrete wavelet trnasform coefficients.

  • PDF

Electric Field Analysis of Power Cable Joint Point using Boundary Element Method (경계요소법을 이용한 전력케이블 접속부의 전계해석)

  • 조경순
    • Journal of the Korea Computer Industry Society
    • /
    • v.4 no.4
    • /
    • pp.579-588
    • /
    • 2003
  • There are many unfavorable conditions that lead to shortening life of cable by causing dielectric breakdown and aging such as field concentrations occurring in intermediate materials linking each cables, penetration of various impurities, and undermining of cable insulation layers. This paper simulated investigated partial discharge properties of XLPE which is widely used for ultra high voltage cable insulation materials and EPDM which is being used as insulation layer of cable joint materials kit, using Boundary Element Method. The result of computer simulation showed that inner-Void defect caused silicone oil to weaken the E-field effect. and we also found that E-field distribution in EPDM remained relatively lower than that in XLPE.

  • PDF