• 제목/요약/키워드: Insulation diagnosis

검색결과 266건 처리시간 0.026초

22.9kV급 케이블 결함 검출을 위한 초저주파 실험 및 현장 진단 분석 (Analysis of Diagnosis and Very Low Frequency Experiment to Detect of Fault on 22.9kV Class Cable)

  • 김영석;김택희;김종민;송길목
    • 전기학회논문지
    • /
    • 제65권10호
    • /
    • pp.1780-1785
    • /
    • 2016
  • This paper presents few case studies of state diagnosis of XLPE cables using very low frequency techniques. The power cables of 22.9kV which have installation fault were assessed using VLF technique in addition to other techniques like insulation resistance and DC voltage withstand test. From the experimental results, The dielectric loss($tan{\delta}$) values of degradation of the cable(joint, knife, needle) at $U_0$ were 5.839, 5.526 and 6.251, respectively and all values were "further study advised". VLF PD measurement was also found defective portion. These method was effective in defect to fault in the degradation of the cable. However, the breakdown did not occur in the degradation of the cable because of properties of XLPE insulation. Few case studies of using VLF $tan{\delta}$ diagnosis for fault are measured and analyzed. The $tan{\delta}$ values at $U_0$ were "further study advised" or "action required".

GIS 절연진단센서 설계와 연면방전에 따른 방사전자파 특성 (A Design of Insulted Diagnosis Sensor and the Characteristics of Frequency Spectrum from the Radiated Electromagnetic Waves according to Surface Discharge)

  • 박숭규;최은혁;이광식
    • 조명전기설비학회논문지
    • /
    • 제26권10호
    • /
    • pp.27-34
    • /
    • 2012
  • If obstacle in GIS(Gas Insulted Switchgear), its affects are great are on the community and it is consequently demanded lots of difficulities to recover and repair. Accordingly, diagnosis techniques, that are able to prevent from accidents before they happen by providing more stable and highly reliable power effectively and finding sign of the accidents is very important. A novel UHF(Ultra High Frequency)-microstrip antenna is presented. The measured impedance bandwidth of the proposed antenna is from 0.5GHz to 15GHz with the stop band from 0.5GHz to 10.7GHz for VSWR<2. Form results of this study, The antenna is will play an important role for the senser for insulation diagnosis system by UHF method of real site GIS and power equipment using $SF_6$ gas.

파괴 및 비파괴진단 비교분석을 통한 케이블 열화특성평가 (Insulation Aging Characteristic Assessment on the Power cables with the Comparative Analysis Between Destructive and Nondestructive Diagnosis)

  • 이동영
    • 조명전기설비학회논문지
    • /
    • 제23권6호
    • /
    • pp.104-108
    • /
    • 2009
  • 본 논문에서는 지중전력케이블을 대상으로 케이블의 절연열화특성 분석시험을 통해 케이블의 절연열화와 절연 진단결과 및 파괴강도와의 상관관계에 대한 실증연구를 수행하였다. 시험대상 선로의 제조결함 여부를 확인하기 위해 가교도분석, 핫오일테스트 등을 실시한 결과 제조결함은 없는 것으로 확인되었다. 진단대상 선로는 3상 모두 장기간 사용에 의해 열화가 많이 진전되었고, 특히 B상이 수트리 길이 및 화학구조결함 농도 면에서 가장 열화된 케이블인 것으로 판단되며, C상, A상의 순으로 열화정도가 다소 감소함을 확인하였다. 상기 결과는 진단시험 및 파괴 강도시험 결과와 일치하며, 따라서 열화시정수법을 이용한 진단장치가 열화상태가 심각한 케이블의 선별에 효과적인 진단법임을 확인하였다.

펄스 신호 및 절연저항 측정 알고리즘을 이용한 전동기 열화 추정 (Estimation of Motor Deterioration using Pulse Signal and Insulation Resistance Measurement Algorithm)

  • 정성인
    • 한국인터넷방송통신학회논문지
    • /
    • 제22권5호
    • /
    • pp.111-116
    • /
    • 2022
  • 전동기 소손의 원인으로는 과부하, 결상, 구속, 층간단락, 권선의 지락, 순간과전압의 유입, 회전자가 고정자에 닿는 경우 등 절연파괴로 이어져 고장 또는 전기 사고로 이어지고 있다. 따라서 기기 고장은 기기의 보수/수리에 필요한 비용에 의한 손실뿐만 아니라, 전동기가 포함된 공정 자체를 멈추기 때문에 공정 정지에 따른 생산성 저하에 의한 막대한 경제적 손실을 초래한다. 전동기의 고장을 진단하기 위한 현재의 기술의 수준은 진동, 열, 전력분석 방식을 이용하고 있지만, 고장에 따른 상당 부분의 시간이 진행되어야 문제점을 분석할 수 있는 한계점을 가지고 있다. 따라서 본 논문에서는 이러한 문제점을 해결하고자 DC AMP 신호를 이용하여 절연저항을 측정하는 장치 및 알고리즘을 산업용 전동기에 적용하여 절연저항 상태값을 추종하여 기존방식에서 해결되지 못한 전동기의 열화 및 고장 진단을 제안한다.

유중 부분방전의 위치 추정 (Positioning of Partial Discharge in Insulation Oil)

  • 길경석;박대원;장운용;서동환;박희철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1861-1867
    • /
    • 2010
  • This paper described the positioning algorithm of partial discharge in insulation oil by acoustic method for the application of an on-line diagnosis in oil-immersed transformers. In the experiment, five AE sensors having the resonant frequency of 150 kHz were used, and a signal conditioner was fabricated. A needle-plane electrode system which is composed of a needle with a curvature radius of $10{\mu}m$ and a plane electrode with a diameter of 60 mm was installed to simulate partial discharges in insulation oil. From the time difference of arrival (TOA) of acoustic signal, we calculated the location of partial discharge in insulation oil. In the experiment, an algorithm of positioning of PD occurrence by the time difference of arrival was proposed. From the experimental results, the positioning error of PD calculated by three AE sensors was within 4%.

  • PDF

6.6 kV 전동기 고정자 권선의 절연진단과 절연내력 평가 (Estimation of Insulation Diagnosis and Dielectric Strength in 6.6 kV Motor Stator Windings)

  • 김희동;공태식
    • 전기학회논문지
    • /
    • 제63권6호
    • /
    • pp.780-785
    • /
    • 2014
  • To assess the deterioration condition of stator insulation, diagnostic and AC dielectric strength tests were performed on five high voltage (HV) motors (2,000 HP, 6.6 kV) for boiler feed-water pump (BFP). Two HV motors for BFP were installed per unit. Following the long term rewinding program, the diagnostic test was performed on five 6.6 kV motors during the planning maintenance period. After completing diagnostic test, AC dielectric strength test was done on the stator windings of HV motors. The AC dielectric strength test was conducted at 15 kV for one minute. Dielectric strength test and diagnostics test results confirmed that the stator insulation was judged to be in serviceable condition in the five 6.6 kV motors.

에폭시/고무 계면에서의 결함에 따른 부분방전 특성 (Chracteristics of Partial Discharge Patterns Subjected to Different Defects at the Epoxy/Rubber Interface)

  • 김동욱;김정년;백주흠
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권5호
    • /
    • pp.199-204
    • /
    • 2002
  • In order to recognize the deterioration of insulation system by partial discharge (PD), the characteristics of PD patterns which are occurring at the interface between epoxy and rubber materials in extra high voltage cable joints, have been investigated. The artificial defects such as voids, metal particles, insulation fiber and water impregnated insulation fiber are planted between the interfaces. A high frequency partial discharge detection system was used for measuring PD signals. An analysis of the PD patterns is focused on the shape of PD pattern, phase, width and time-dependence for each artificial defect. The PD Patterns in each defect show the different behaviors and it is suggested that the precise discrimination of PD patterns could be used for the diagnosis of deterioration in the insulation systems.

Partial Discharge Ultrasonic Analysis for Generator Stator Windings

  • Yang, Yong-Ming;Chen, Xue-Jun
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.670-676
    • /
    • 2014
  • The objective of this research is to utilize the ultrasonic method to analyze the property of partial discharge (PD) which is generated by the winding of the insulation stator in the generator. Therefore, a PD measurement system is built based on ultrasonic and virtual instruments. Three types of PD models (internal PD model, surface PD model and slot PD model) have been constructed. With the analysis of these experimental results, this research has identified the ultrasonic signals of the discharges which were produced by three types of PD models. This analysis shows the different features among these PD types. Both the time domain and frequency domain of the ultrasonic signals are obviously different. In addition, an experiment based on a large rotating machine has been done to analyze ultrasonic noises. The result indicates that the ultrasonic noises can be wiped off by the filters and algorithms. The application of this system is convenient for the detection of early signs of insulation failure, which is an effective method for diagnosis of insulation faults.

실리콘 처리에 의한 수트리 열화케이블의 절연회복 (Insulation rehabilitation of water tree aged cables by silicone treatment)

  • 김주용;송일근;한재홍;이동영;문재덕
    • 조명전기설비학회논문지
    • /
    • 제14권1호
    • /
    • pp.14-21
    • /
    • 2000
  • 본 논문은 수트리 열화된 가교폴리에틸렌(XLPE) 절연 지중케이블의 절연회복을 위해 개발된 실리콘 처리 기법의 현장적용 가능성을 검토하기 위해 수트리 열화된 325 $\textrm{mm}^2$ CN/CV 케이블을 수거하여 실리콘 처리하고, 시간의 경과에 따른 절연성능 향상도를 분석한 것이다. 시료 케이블의 절연회복을 평가하기 위해 교류절연파괴시험을 실시했다. 또 실리콘 처리케이블의 평가를 위해 진단시험 및 케이블 특성평가를 수행했다. 실리콘 처리후 1년 경과 시료 케이블올 분석한 결과, 실리콘액(silicone fluid)과 수분이 효과적으로 결합해 절연파괴강도가 상당히 증가한 것으로 나타났다. 실험결과를 종합해 볼 때 수트리로 열화된 케이블의 절연성능 향상에 실리콘 처리가 효과적인 것으로 나타났다.

  • PDF

Characteristics of Insulation Diagnosis and Failure in Gas Turbine Generator Stator Windings

  • Kim, Hee-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.280-285
    • /
    • 2014
  • In order to evaluate the insulation deterioration in the stator windings of five gas turbine generators(137 MVA, 13.8 kV) which has been operated for more than 13 years, diagnostic test and AC dielectric breakdown test were performed at phases A, B and C. These tests included measurements of AC current, dissipation factor, partial discharge (PD) magnitude and capacitance. ${\Delta}I$ and ${\Delta}tan{\delta}$ in all three phases (A, B and C) of No. 1 generator stator windings showed that they were in good condition but PD magnitude indicated marginally serviceable and bad level to the insulation condition. Overall analysis of the results suggested that the generator stator windings were indicated serious insulation deterioration and patterns of the PD in all three phases were analyzed to be internal, slot and spark discharges. After the diagnostic test, an AC overvoltage test was performed by gradually increasing the voltage applied to the generator stator windings until electrical insulation failure occurred, in order to determine the breakdown voltage. The breakdown voltage at phases A, B and C of No. 1 generator stator windings failed at 28.0 kV, 17.9 kV, and 21.3 kV, respectively. The breakdown voltage was lower than that expected for good-quality windings (28.6 kV) in a 13.8kV class generator. In the AC dielectric breakdown and diagnostic tests, there was a strong correlation between the breakdown voltage and the voltage at which charging current increases abruptly ($P_{i1}$, $P_{i2}$).