• 제목/요약/키워드: Insulation design

검색결과 889건 처리시간 0.037초

전동차 견인용 유도전동기 절연 설계 (Insulation Design of the Induction Motor for Subway Traction)

  • 이정일;이종인;김기찬;이갑재;김진호;최영찬;박정태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.333-335
    • /
    • 1999
  • In this paper, the insulation system of induction motor for subway traction was designed. In order to design the insulation system of induction motor, various types of insulation system were compared, at first, and test method was investigated in order to verify the designed insulation system. The designed insulation system was satisfied economically, technically by experimental test.

  • PDF

국내 가공송전선로 절연설계기술의 발전 및 적용 (Progress and application on the insulation design of overhead transmission line in Korea)

  • 유철환;김경호;박순규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.416-418
    • /
    • 2000
  • Main power transmission network in Korea is consist of 154kV, 345kV transmission lines. Also 765kV transmission lines are on construction currently. There are some differences in the insulation design concept, methods and contents on 154kV, 345kV and 765kV overhead transmission lines respectively. In this paper, we described and summarized the applied insulation design concept, methods and features on each transmission lines.

  • PDF

알미늄 압출재의 차음 구조 설계 (Design of Aluminium Extruded Panel for Sound Insulation)

  • 서태건;김석현;김정태;송달호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.996-999
    • /
    • 2010
  • Aluminium extruded panel is the most important element for sound insulation in a express train. However, comparing with the flat plate with the same weight, the extruded panel shows remarkably low sound transmission loss above the 1st local resonance frequency, which is determined by the dimension of the core structure. Preceding study showed the possibility of the improvement of sound insulation performance by properly designing the core dimension. By the proper core design, local resonance frequency shifts to higher frequency region without any reduction of bending or torsional strength and without any weight increase. Based upon this result, this study investigates in detail the design modification of the core structure of the aluminium extruded panel used in a express train under development, in aspect of sound insulation. Design result is compared with those of other developed models.

  • PDF

Double Pancake형 고온초전도 변압기의 전기적 절연 특성 (Dielectric Insulation properties of Double Pancake coil type HTS Transformer)

  • 백승명;정종만;이정원;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.494-498
    • /
    • 2002
  • HTS transformer experimentally. High temperature superconductors can only be applied against an engineering specification that has to be determined for each particular application form the design requirements for economic viability and for operation margins in service. High temperature superconducting(HTS) power apparatus are very promising candidates for application. Especially, these advantages make superconducting transformers very promising candidates for application in electrical power engineering and locomotives. In order to realize the HTS transformer, it is necessary to establish the high voltage insulation technique in cryogenic temperature. So far, insulation research of Pancake type HTS transformer is lacking nothing but insulation research of . solenoid type transformer consisted. Therefore, the composite insulation of double pancake coil type transformer are described and ac breakdown voltage characteristics of liquid nitrogen(LN$_2$) under HTS pancake coil electrode made by Bi-2223/Ag are studied. Breakdown in LN$_2$ is dominated electrode shape and distance. The relation between surface flashover voltage is considered for FRP. This research presented basis information of electrical insulation design for double pancake coil type HTS transformer.

  • PDF

수면 열환경에 관한 연구 (II) -침구의 경량화에 따른 보온력- (Studies on the Thermal Environment in Sleeping (II) -Thermal Insulation Effect of Bedding on Lightweight-)

  • 성수광
    • 한국의류학회지
    • /
    • 제17권3호
    • /
    • pp.470-474
    • /
    • 1993
  • This study carried out to get some fundamental data for designing lightweight bedding. In This study, the wool blanket, polyester/cotton blended blanket and down quilt were manufactured with a varied materials, structural factors such as yam count, fabric density respectivelyarn. And also, the thermal insulation value of the bedding were measured by warmth retaining tester. In addition, this paper examines the influence of varying materials, structural factors and blanket layers on the thermal insulation effect of the bedding. The main results obtained from this study are as follow : 1. The design of lightweight blankets make an attempting with a varying materials and structural factors such as yam count, fabric densityarn. 2. Almost, the design of lightweight blankets for polyester/cotton blended blanket and down quilt make an attempting without reduction in thermal insulation values. 3. The 6 layers of blanket have less thermal insulation value than the 6 times of blanket for under a layer have. About 27~32% decrease is observed in thermal insulation value of blanket for under 6 layer. 4. The thermal insulation value and areal weight of blankets have a positive relation between the thermal insulation value(Y) and areal weight(X) is based on the following equation. wool blanket : Y = 1.0850X + 0.4188 (r = 0.9992) PIC blended blanket : Y = 0.8845X + 0.3034 (r = 0.9999)

  • PDF

기능성과 보온성 향상을 위한 공군 정비파카 개발 및 평가 (Development and Evaluation of Air Force Mechanic Parka to Enhance the Functions and Insulation)

  • 이성지;최영림;남윤자
    • 한국의류산업학회지
    • /
    • 제14권2호
    • /
    • pp.294-303
    • /
    • 2012
  • This study was designed to develop air force mechanic parka, evaluate it, and ultimately provide functionally superior parka to the air force. The development process was 1) conducting a survey, 2) identifying problems and shortcomings of currently-supplied parkas, and 3) improving the design, pattern and materials. The newly-developed parkas were evaluated in terms of their ease of fit, clothing mobility, and insulation. Ease of fit was evaluated by subjects' sensory tests, and clothing mobility was by fitness-for-motion tests and range-of-motion tests using a Goniometer. Evaluation on insulation was conducted by thermal manikins. Findings of this study were as follows: 1. In the subjective evaluation on clothing mobility, new parkas were considered to have sufficient ease of fit while previous ones scored much lower, confirming the improvement of the new version. 2. Both subjective tests and ROM measurements on fitness for motion verified the superiority of the new parkas. 3. Insulation tests found that although insulation capability of newly-developed parkas was at a similar level to those of the previous ones, their insulation capability per unit weight was superior, demonstrating that new parkas were better at blocking heat conduction. When making changes in parka patterns and designs to enhance the mobility, it was necessary to maintain the insulation function. The new parkas developed by this study was verified to be superior to the previous ones in their insulation and clothing mobility.

현장타설 중단열 RC벽체의 구조적 성능 (Structural Performance for Sandwich Insulation of Reinforced-Concrete)

  • 박준호;유정호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.19-20
    • /
    • 2015
  • Building exterior wall's energy loss is very high rate comparing to all part of a buildings. And it account for upper 40% of cooling and heating load. So many studies conducted improving insulation performance of building's exterior, appeared about sandwich insulation wall which could be gaining merit of traditional insulation method those are exterior insulation and interior insulation. In this study, we inform structural performance of sandwich insulation wall for RC wall. For this, first, we define each wall's role and design sandwich insulation wall. At last, analyze structural performance of sandwich insulation wall. This study can contribute to apply it safely where side wall which toilet, stair area, etc.

  • PDF

고무 발포 배관 보온 단열재의 성능 기준 및 평가 (Performance Standards and Evaluation of Elastomeric Flexible Cellular Insulation)

  • 전현석;최현중;최경석;강재식;이승언;정광섭
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.614-617
    • /
    • 2009
  • Elastomeric Flexible Cellular Insulation is widely used in construction fields to prevent condensation and frozen pipes, reduce energy, and improve insulation. However, when Elastomeric Flexible Cellular Insulation has been installed in buildings in Korea, there was no standardization, which resulted in heat loss Therefore, insulation design standards need to be developed and from these standards, pipe insulation should be improved to increase its efficiency. This study estimates temperature and surface-emissivity according to the thickness of insulation to evaluate thermal performance.

  • PDF

배전급 전력설비를 위한 친환경 가스의 절연성능검토 (Review of Insulation Performance in Synthetic Air and Dry Air for High Voltage Equipment in Distribution Class)

  • 임동영;최은혁;최병주;최상태;이광식;배성우
    • 조명전기설비학회논문지
    • /
    • 제29권12호
    • /
    • pp.33-39
    • /
    • 2015
  • This paper examines the insulation performance of synthetic air and dry air. This examination was conducted based on dielectric strength in uniform and non-uniform field, electric field distribution by interior structure and defects in gas insulation switchgear (GIS) and insulation performance in different temperatures. From this review, it was found that eco-insulation gas required to possess low moisture content for power equipment in the distribution class. The results of this paper are valuable to ensure the insulation design and insulation reliability of GIS using air.

원전 금속단열재의 구조 건전성 강화를 위한 설계 방안 (Design for Strengthening Structural Integrity of the Reflective Metal Insulation in the Nuclear Power Plant)

  • 이성명;어민훈;김승현;장계환
    • 한국안전학회지
    • /
    • 제30권3호
    • /
    • pp.107-113
    • /
    • 2015
  • The goal of this paper is to investigate structural integrity factors of RMI(reflective metal insulation) to confirm the design requirements in nuclear power plant. Currently, a glass wool insulation is using now, but it will gradually be replaced with the reflective metal insulation maded by stainless steel plates. The main function of an insulation is to minimize a heat loss of vessel and pipes in RCS(reactor coolant system). It has to maintain structural a integrity in nuclear power plant life duration. In this study, the structural integrity analysis was carried out both multi-plate and outer shell plate by using a static analysis and experimental test. First, inner multi-plate has a self support structure for being air space. Because the effect of total static weight in multi-layer plate is low, a plate collapse possibility is not high. Considering optimum thin plate pressing process, it has to pre-check the basic physical properties. Second, the outer segment thickness and stiffener shape are verified by the numerical static analysis, and sample test for both type of panel and cylindrical pipe model.