• 제목/요약/키워드: Insulation breakdown strength

검색결과 178건 처리시간 0.021초

지중 배전케이블의 최적 교체기준 수립을 위한 열화진단 및 특성분석 (Aging Diagnosis and Characteristic Analysis of Distribution ,Power Cables I to Prepare Optimal Replacement Criterion)

  • 김주용;송일근;정익중;한명관;심유종;문재덕
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권5호
    • /
    • pp.258-263
    • /
    • 2004
  • The purpose of this experiment is to modify diagnosis criterion of isothermal relaxation current(IRC) measurement equipment which is using for distribution cable diagnosis. We're using this system for several years in the field instead of DC leakage current measurement and lots of cables were replaced. But we have to investigate on the reliability of this equipment for our cables because we didn't carried out condition assessment of extracted cables after field diagnosis by this equipment. It is important thing for cable maintenance. If the replacement criterion is improper we can not prevent failures or will waste budget on account of replacement of the sound cables. In this paper we selected field installed cables and injected silicone fluid to the cables for insulation rehabilitation. In order to prove reliability of the diagnosis equipment we compared diagnosis results and AC breakdown strength according to operating time after silicone treatment. This is the results of the field test for 1 year.

절연체의 내아크성 평가를 위한 안테나 기법의 적용에 관한 연구 (Study on the application of antenna method for the criterion test of insulator arc resistance)

  • 이강원;김명룡;강성화;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.57-60
    • /
    • 2004
  • Electrical arc is the final stage of insulation breakdown and has high current density which cause heat and light in insulator. Insulator under electrical arc lost its insulating strength and eternal damages. Conventional criterion of electrical arc resistance in Standards have depended on the change of sound pressure and light color after damages on insulator by electrical arc. The recognition of these changes is done by human himself which was very subjective and resulted in some error to judge whether insulator has damages or not. This paper has shown that antenna method is the appropriate measure to judge electrical arc resistance for insulator. Antenna measures the electromagnetic waves radiated from tungsten electrodes with 6mm gap regulated by KSC2130. Applied voltage cross two tungsten electrodes have two different methods such as 1/8 10 and continuous 10mA. Signal amplitudes obtained by antenna has diminished after the damage of insulator, which will provide objective and good way to judge the electrical arc resistance.

  • PDF

실리콘 고무의 플라즈마 표면처리된 반도전-절연계면 처리에 따른 접착특성과 절연성능 (Adhesion and Electrical Performance by Plasma Treatment on Semiconductive-Insulation Interface Layer of Silicone Rubber)

  • 황선묵;이기택;홍주일;허창수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.11-14
    • /
    • 2004
  • In this paper, the effect of adhesion properties of semiconductive-insulating interface layer of silicone rubber on electrical properties was investigated. The modifications produced on the silicone surface by oxygen plasma were accessed using ATR-FTIR, contact angle and AFM. Adhesion was obtained from T-peel tests of semiconductive layer having different treatment durations. In addition, ac breakdown test was carried out for elucidating the change of electrical property with duration of plasma treatment. From the results, the treatment in the oxygen plasma produced a noticeable increase in surface energy, which can be mainly ascribed to the the creation of O-H and C=O. It is observed that adhesion performance was determined by not surface energy but roughness level of silicone surface. It is found that ac dielectric strength was increased with improving the adhesion between the semiconductive and insulating interface.

  • PDF

부분방전검출 신뢰도 향상을 위한 UHF 센서개선 및 성능검증 (Performance Verification and Improvement of UHF Sensor for the Increasement of the Partial Discharge Detection Reliability)

  • 김원규;김민수;백영식
    • 전기학회논문지
    • /
    • 제63권10호
    • /
    • pp.1461-1466
    • /
    • 2014
  • GIS(Gas Insulated Switchgear) is important power apparatus which have strong dielectric strength, supply electric power and is a part of the power system. Most substation type is configured as GIS. Recently, because of continuous increasement of GIS demand resulted from high quality & big capacity of electric power, the necessity of the preventive & diagnosis system is being expanded gradually. GIS partial discharge occurred on the UHF band is detected effectively by the method to IEC 60270 that recommend to be able to detect the apparent minimum discharge, 5 pC. Additionally, the UHF sensor should be installed to detect PD signal if Partial discharge signal, 5 pC occur in every part of GIS. Currently PD diagnosis system applying UHF sensor for GIS with various voltage level like 154 kV, 345 kV, 765 kV have been operated. And it is necessary to measure and analyze insulation breakdown phenomenon of inside GIS exactly. In this paper, we proposed Fat-dipole patch UHF sensor that is developed and more sensitive, excellent wide-range characteristic than the exising UHF sensor. And we performed KERI (Korea Electrotechnology Research Institute) reference test, which showed the excellent result for the all tests.

가속열화 된 CSPE의 경화특성에 미치는 해수 담수 침지의 영향 (Effects of Seawater & Freshwater Soaking on the Cure Properties of Accelerated Thermally Aged CSPE)

  • 신용덕;이정우
    • 전기학회논문지
    • /
    • 제65권5호
    • /
    • pp.819-824
    • /
    • 2016
  • The accelerated thermal aging of CSPE (chlorosulfonated polyethylene) was carried out for 33.64 and 67.27 days at 110[$^{\circ}C$], equivalent to 40 and 80 years of aging at 50[$^{\circ}C$], respectively. These samples were referred to as CSPE-0y, CSPE-40y and CSPE-80y, respectively. As the accelerated thermally aged years of the CSPE increase, the insulation resistance[$\Omega$] at 20[Hz], 500[Hz], and 2[KHz], and the percent elongation [%EL] of the CSPE decrease. However, the dissipation factor($tan{\delta}$) at 20[Hz], 500[Hz], and 2[KHz], the apparent density[$g/cm^3$], the glass transition temperature and the melting temperature of the CSPE were increased. The period of time that the voltage has to be applied until electric breakdown of the CSPE-0y is longer than that of the CSPE-40y, and the CSPE-80y, but the dielectric strength of the CSPE-80y is lower than that of the CSPE-0y and the CSPE-40y. The differential temperatures after the AC and DC voltages are applied to CSPE-0y, CSPE-40y and CSPE-80y are 0.026~0.028[$^{\circ}C$], 0.030~0.042[$^{\circ}C$], 0.018~0.045[$^{\circ}C$], respectively. The variations of temperature for the AC voltage are higher than those for the DC voltage when an AC voltage is applied to CSPE-0y, CSPE-40y and CSPE-80y. It is found that the dielectric loss owing to the dissipation factor[$tan{\delta}$] is related to the electric dipole conduction current. It is ascertained that the ionic (electron or hole) leakage current is increased by the separation of the branch chain of CSPE polymer from the main chain of the polyethylene as a result of thermal stress due to accelerated thermal aging as well as by conducting ions such as $Na^+$, $Cl^-$, $Mg^{2+}$, $SO_4^{2-}$, $Ca^{2+}$ and $K^+$ after seawater soaking.

석탄회를 활용한 CLSM의 열전도도에 관한 실험적 연구 (An Experimental Study on Thermal Conductivity of Controlled Low Strength Materials with Coal Ash)

  • 이승준;이종휘;조현수;천병식
    • 대한토목학회논문집
    • /
    • 제32권3C호
    • /
    • pp.95-104
    • /
    • 2012
  • 라이프라인의 공간 창출 및 미관 등의 이유로 지하공간의 개발이 활발해짐에 따라 지중하부에 매설되는 관(pipe)은 점차 증가하고 있으며 새로운 재료를 활용한 관거 뒤채움용 CLSM(Controlled Low Strength Materials)에 관한 연구의 비중은 점점 증가하고 있는 추세에 있다. 그리고 지중송전케이블에서 송전으로 인하여 발생된 열을 뒤채움재가 효과 적으로 방출시키지 않으면 절연파괴에 이를 수 있으므로 뒤채움재는 반드시 우수한 열적 특성을 필요로 한다. 한편, 산업부산물인 석탄회는 매년 상당한 양이 발생되고 있으며, 그 중 매립회(ponded ash, PA)는 재활용되지 못하고 회처리장에 매립되고 있다. 본 연구에서는 산업폐기물인 석탄회를 활용한 관거 뒤채움용 CLSM의 열전도도 특성을 규명하기 위하여 배합비에 따른 열전도도(thermal conductivity) 시험을 실시하여 값의 변화를 검토하였다. 시험결과, 배합비(PA:FA) = 80:20, water contents = 28~30%, cement contents = 7, 9, 11%에서 0.796-0.884W/mK을 나타냈으며 이는 타 배합비보다 높은 열전도도를 나타내었으며 현재 폐기물로 처리되고 있는 매립회를 대량 유효 활용하는 측면에서 적합할 뿐 아니라 전력 및 통신 등 관거 뒤채움재로서의 활용이 클 것으로 판단된다.

이축 연신된 폴리프로필렌 필름의 전하주입 현상이 절연특성에 미치는 영향 (Influence of the Insulating Properties on Charge Injection Phenomena of Biaxially-Drawn Polypropylene Film)

  • 이준웅;김병태;박승협
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제1권2호
    • /
    • pp.74-81
    • /
    • 1987
  • 고분자 절연재료에 전하주입시 발생하는 캐리어 트랩현상은 재료의 절연성을 저하시키는데 중요한 영향을 미치는 것으로 알려져 있다. 따라서 본 연구에서는 절연재료의 전기적 특성을 개선한다는 측면에서 캐리어의 거동을 파악하기 위해 내열성이 폴리프로필렌보다 우수한 이축 연신된 폴리프로필렌 필름(두께 $50\mu\textrm{m}$)을 선정하여 전계변화에 따른 열자격전류 스펙트라를 분석 검토하였다. 온도범위 303~413[K]와 전계범위 2~80[㎹/m]에서 열자격 전류의 변화를 살펴본 결과 전계 12[㎹/m]이하에서는 전하주입의 효과가 관찰되지 않았으나 전계가 점점 높아지면 트랩된 공간전하와 전극으로부터 주입된 공간전하가 형성되어 Hetero 및 Homo성 열자격전류 스펙트라가 나타나며 이는 결국 절연파괴를 야기시키는 것으로 예측되어진다. 또한 이축 연신된 시료가 미연신 재료보다 우수한 절연특성을 가지고 있음을 확인 할 수 있었다.

  • PDF

마이카 고전압 커패시터의 환경시험과 가속 수명시험을 통한 신뢰성 평가 (Reliability assessment of mica high voltage capacitor through environmental test and accelerated life test)

  • 박성환;함영재;김정석;김경훈;소성민;전민석
    • 한국결정성장학회지
    • /
    • 제29권6호
    • /
    • pp.270-275
    • /
    • 2019
  • 마이카 커패시터는 세라믹 커패시터에 비해 내고충격 특성이 우수하여 다양한 유도무기체계의 고전압 기폭장치에 적용된다. 본 연구에서는 국산화된 마이카 고전압 커패시터의 고전압 기폭장치 적용을 위해 단자강도시험, 내습성시험, 열충격시험과 같은 환경시험과 함께 가속 수명 시험을 진행하였다. 마이카 고전압 커패시터의 고장모드는 절연저항 감소 및 이를 통한 절연 파괴이다. 가속수명모델의 중요 상수를 실험적으로 도출하였으며 전압계수 n 및 활성화 에너지 Ea는 각각 5.28 및 0.805 eV이었다. 가속모델식을 이용하여 도출한 가속계수는 496이었으며 가속수명시험을 통해 도출된 정상 사용 조건에서의 마이카 고전압 커패시터의 수명은 38.5년으로 기폭장치 적용에 문제가 없는 것으로 확인되었다.