• 제목/요약/키워드: Insulation System

검색결과 1,387건 처리시간 0.029초

고온초전도 케이블용 cryostat의 단열조건에 대한 열침입량 측정 (Experiment on Heat Loads Invaded into HTS Cable Cryostat under Cryogenic Insulation System)

  • 김도형;정원묵;김동락;양형석;조승연;황시돌
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1564-1569
    • /
    • 2004
  • Insulating a heat from the environment is the most important in cryogenic applications like HTS cable system. Vacuum and MLI(Multi-Layer Insulation) have been widely used to get highly efficient cryogenic insulation. In this study, experiment on annular cylinder regarded as basic model of HTS cable cryostat has been performed to measure the heat loads. To investigate the effectiveness of radiation shields in cryogenic insulation system, the experiments are carried out to various number of the shields. The measured values are compared with the results estimated theoretically. The heat loads invaded from the environment was determined by liquid nitrogen boil-off calorimetry.

  • PDF

고온초전도 케이블의 유전 특성 (Dielectric Characteristics of HTS Cable)

  • 곽동순;김해종;조전욱;성기철;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 제4회 영호남학술대회 논문집
    • /
    • pp.64-68
    • /
    • 2002
  • According to the increasing power demand for the future construction of many underground cables will be required. However, construction of new ducts for power cables will be more difficult. Therefore, research work for realizing the high temperature superconducting(HTS) cable has advanced, where the development of electrical insulating system at cryogenic temperature is one of the major researches. For an electrical insulation design of HTS cable, it is important to understand not only breakdown but also partial discharge and dielectric loss($tan{\delta}$) in liquid nitrogen/paper composite insulation system. In this paper, we investigated breakdown characteristics in liquid nitrogen/paper composite insulation system for the application to HTS cable. And, we studied the breakdown characteristics of the multi-layer and butt gap of the insulation papers in liquid nitrogen. Also, we measured dielectric loss($tan{\delta}$) of the mini-model Cable made of TERLAM IPP.

  • PDF

$SF_{6}$가스와 절연지의 절연계에서 가스압력에 따른 부분방전 현상(II) (Partial Discharge Phenomena with $SF_{6}$ Gas Pressures in Insulation Consisted of Insulation Paper and $SF_{6}$ Gas(II))

  • 선종호;김광화;박정후;조정수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권9호
    • /
    • pp.430-435
    • /
    • 2002
  • The $SF_{6}$ gas insulated power equipments have the insulation systems which are composed of $SF_{6}$ gas and insulation paper. It is repored that their insulation abilities are influenced by the $SF_{6}$ gas gaps in those insulation systems and gas pressures. This paper describes partial discharge phenomena with $SF_{6}$ gas pressures in insulation system of $SF_{6}$ gas-insulation paper Specimens of $SF_{6}$ gas-insulation paper were prepared and aramid paper was used as insulation paper. Partial discharge inception voltages(PDIV) and breakdown voltages for the existence of $SF_{6}$ gas gaps were measured by short term tests with gas pressures. Also, average PD quantities and pulse counts, life times of each specimens were calculated from the results of long term aging tests with gas pressures. It was found that the $SF_{6}$ gas gaps decrease increasing rates of PDIV and brealdown voltages according to gas pressure increase and the insulation breakdown caused by the smaller PD quantities than 1[pC] at the high gas pressure of 300kPa is due to the increase of energy density with increase of gas pressure.

그린팀버월 패널의 열전달 특성 (Heat transfer of green timber wall panels)

  • 김윤희;장상식;신일중
    • 농업과학연구
    • /
    • 제38권1호
    • /
    • pp.115-120
    • /
    • 2011
  • 20% of total energy use to sustain temperature of building inside. In this reasons, researchers effort to improve the thermal insulation capacity with new wall system. Using appropriate materials and consisting new wall system should considered in energy saving design. OSB(Oriented strand board), Larch lining board used to consist wall system. $2{\sim}6$ Larch lining board has tongue & groove shape for preventing moisture. Comparing with gypsum board and green timber lining board as interior sheathing material, temperature difference of Green timber wall system was bigger than temperature difference of gypsum board wall system. This aspects indicate that Green timber wall system was revealed higher thermal insulation property than gypsum board wall system. Gypsum board portion transfer heat easily because temperature difference gradient of gypsum board wall system was smaller than OSB wall system. Total temperature variation shape of G-4-S and G-6-S show similar model but, temperature variation shape in green timber wall portion assume a new aspect. The purpose of this study was that possibility of thermal insulation variation and new composition of wall system identify to improve thermal insulation performance. In the temperature case, this study shows possibility of improving thermal insulation performance. Humidity, sunshine and wind etc. should considered to determine building adiabatic properties.

공동주택 층간단열 완충재의 열에너지 특성의 관한 연구 (A Study on the Evaluation for Energy Characteristic of Absorber Floor Insulation of Apartment House)

  • 최동혁;최경석;강재식;이승언;조우진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.712-717
    • /
    • 2009
  • Ondol is a tradtional Korea heating system with a long history. The ondol heating system is a default in ordinary houses and high-rise apartment alike. But Intensified Architecture Law insulation standard can't satisfied standard insulation only light weight concrete in ondol. The between light weight concrete and slab apply EPS insulation is construct for generate a method of construction. The standard insulation for floor heating system is responsible but complicate construction thermal transmittance and absorber, deteriorate the cost and decreasing the performance insulation & impact floor sound. In study on the evaluation decrease heating-load of floor construction of the insulation & absorber that improvement floor a Apartment house.

  • PDF

SF6 가스 절연변압기의 절연특성과 부분방전 (Insulation Characteristics and Partial Discharge for the SF6 Gas Insulated Transformer)

  • 선종호;김우성;김광화;오원근;하영식
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.740-747
    • /
    • 2000
  • This paper describes insulation characteristics and partial discharge for the SF6 gas insulated transformer. The characteristic of gas insulated transformer and the degradation sequence of solid insulation under SF6 gas atmosphere were explained. The model electrode system of the types that the aramid papers were inserted between two sphere electrodes was prepared. The partial discharge tests were carried out to that system and the insulation characteristics were considered.

  • PDF

LNG 벙커링용 이중 단열적용 LNG 저장탱크 열해석 (Thermal Analysis on the LNG Storage Tank of LNG Bunkering System Applied with Double Shield Insulation Method)

  • 정일영;김남국;윤상국
    • 한국가스학회지
    • /
    • 제22권4호
    • /
    • pp.1-6
    • /
    • 2018
  • IMO에서 규정하는 LNG 벙커링 선박용 연료 탱크 중 C형 가압탱크는 내외 2중 용기로 구성된 초저온 탱크에 $10^{-2}$ Torr 진공과 펄라이트 단열재가 충전되는 것이다. 그러나 이 단열방식은 LNG 기화량이 하루당 2.0 % 내외로 증발율이 커서 보다 단열효과가 좋은 탱크가 요구되어 진다. 본 연구에서는 내외탱크 사이에 고진공을 적용하고 외부탱크의 내벽체에 중간 단열로 펄라이트 진공단열을 적용하는 단열 방식을 새로이 고안하여 열해석을 수행하였다. 이의 장점으로는 진공 공간의 감소로 고진공 형성 시간을 크게 감소되고, 진공도 $10^{-4}$ Torr 이하에서 하루당 증발율이 0.16 %에 불과한 매우 효율이 높은 탱크 단열방식이 되었다. 만약 현재의 IMO C형 탱크의 진공펄라이트 단열에서 진공이 파괴되는 경우, C형 탱크는 하루당 4.9 %의 증발이 발생하고 새 고안 탱크는 5.23 %로 거의 동일하게 된다.

Effects of the structural strength of fire protection insulation systems in offshore installations

  • Park, Dae Kyeom;Kim, Jeong Hwan;Park, Jun Seok;Ha, Yeon Chul;Seo, Jung Kwan
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제13권1호
    • /
    • pp.493-510
    • /
    • 2021
  • Mineral wool is an insulation material commonly used in passive fire protection (PFP) systems on offshore installations. Insulation materials have only been considered functional materials for thermal analysis in the conventional offshore PFP system design method. Hence, the structural performance of insulation has yet to be considered in the design of PFP systems. However, the structural elements of offshore PFP systems are often designed with excessive dimensions to satisfy structural requirements under external loads such as wind, fire and explosive pressure. To verify the structural contribution of insulation material, it was considered a structural material in this study. A series of material tensile tests was undertaken with two types of mineral wool at room temperature and at elevated temperatures for fire conditions. The mechanical properties were then verified with modified methods, and a database was constructed for application in a series of nonlinear structural and thermal finite-element analyses of an offshore bulkhead-type PFP system. Numerical analyses were performed with a conventional model without insulation and with a new suggested model with insulation. These analyses showed the structural contribution of the insulation in the structural behaviour of the PFP panel. The results suggest the need to consider the structural strength of the insulation material in PFP systems during the structural design step for offshore installations.

컴퓨터 비전 기반 외단열 공사의 접착제 도포품질 감리 자동화 모델 (Computer Vision-based Automated Adhesive Quality Inspection Model of Exterior Insulation and Finishing System)

  • 윤세빈;강민균;장현승;김태훈
    • 한국건축시공학회지
    • /
    • 제23권2호
    • /
    • pp.165-173
    • /
    • 2023
  • 본 연구에서는 외단열 공사의 단열재 접착제 도포 품질을 자동으로 감리할 수 있는 모델을 제안하였다. 사례 적용 결과, 영역 분할 모델은 mAP 92.3%의 정확도를 나타냈고, 제안 모델의 접착제 면적 비율 산출 정확도는 98.8%, 접착제 덩어리 중심 간 거리 산출 정확도는 96.7%로 나타났다. 본 연구 결과는 외단열 공사의 감리를 위한 현장투입 인력을 최소화하면서 외단열 공사의 가장 빈번한 하자인 단열재 탈락 하자를 예방할 수 있으며 나아가 외단열 시스템의 활성화에 기여할 수 있을 것으로 판단된다. 향후에는 다양한 환경에서 외단열 공법의 시공 영상을 수집하여 영상 분할 모델의 성능을 높이고, 영상 내에 다수의 단열재가 포함된 경우에도 자동 감리할 수 있는 모델을 개발하고자 한다.

광유 및 식물성 절연유에서 절연지의 열적 열화 특성 평가 (The Evaluation of Thermal Aging for Insulation Paper with Mineral and Vegetable Oil)

  • 이병성;송일근;김동명;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1558-1560
    • /
    • 2004
  • Liquid-immersed pole transformers have utilized an insulation system consisting of natural cellulose-based materials and mineral oil for many years. If the transformers are installed with the abruptly changing load over limitation, its insulation materials are apt to unexpected aging with high temperature. Therefore we have been conscious of developing a transformer that is more thermally stable then conventional types. To measure temperature distribution in the winding of conventional and newly designed transformers, temperature sensors were installed fordirect reading of oil and conductor temperatures at transformers. And we conducted accelerating aging test for these transformers. The measuring data had made use of the design to hybrid insulation system. Also we could find the possibility of this insulation system to apply in pole mounted transformers.

  • PDF