• Title/Summary/Keyword: Insulation Strength

Search Result 638, Processing Time 0.028 seconds

Adhesion and Electrical Performance by Roughness on Semiconductive-Insulation Interface Layer of Silicone Rubber (거칠기에 따른 반도전-절연 계면층에서 접착특성과 절연성능)

  • Lee, Ki-Taek;Hwang, Sun-Mook;Hong, Joo-Il;Huh, Chang-Su
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.78-81
    • /
    • 2004
  • In this paper, the effect of adhesion properties of semiconductive-insulating interface layer of silicone rubber on electrical properties was investigated. Surface structure and adhesion of semiconductive silicon rubber by surface asperity was obtained from SEM and T-peel test. In addition, ac breakdown test was carried out for elucidating the change of electrical property by roughness treatment. From the results, Adhesive strength of semiconductive-insulation interface was increased with surface asperity. Dielectric breakdown strength by surface asperity decreased than initial Specimen, but increased from Sand Paper #1200. According to the adhesional strength data unevenness and void formed on the silicone rubber interface expand the surface area and result in improvement of adhesion. Before treatment Sand Paper #1200, dielectric breakdown strength was decreased by unevenness and void which are causing to have electric field mitigation small. After the treatment, the effect of adhesion increased dielectric breakdown strength. It is found that ac dielectric breakdown strength was increased with improving the adhesion between the semiconductive and insulating interface.

  • PDF

Evaluation of Cryogenic Compressive Strength of Divinycell of NO 96-type LNG Insulation System (NO96타입 LNG 방열시스템 Divinycell의 극저온 압축 강도 평가)

  • Choe, Yeong-Rak;Kim, Jeong-Hyeon;Kim, Jong-Min;Park, Sungkyun;Park, Kang Hyun;Lee, Jae-Myung
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.5
    • /
    • pp.349-355
    • /
    • 2016
  • Divinycell, which functions as both insulation and a supporting structure, is generally applied in the NO96-type liquefied natural gas (LNG) insulation system. Polymer-material-based Divinycell, which has a high strength and low weight, has been widely used in the offshore, transportation, wind power generation, and civil engineering fields. In particular, this type of material receives attention as an insulation material because its thermal conductivity can be lowered depending on the ambient temperature. However, it is difficult to obtain research results for Divinycell, even though the component materials of the NO96-type LNG cargo containment system, such as 36% nickel steel (invar steel), plywood, perlite, and glass wool, have been extensively studied and reported. In the present study, temperature and strain-rate dependent compressive tests on Divinycell were performed. Both the quantitative experimental data and elastic recovery are discussed. Finally, the mechanical characteristics of Divinycell were compared to the results of polyurethane foam insulation material.

A Study on Improvement of Adhesion HTPB Propellant/Liner/Insulation (HTPB계 추진제/라이너/내열재의 접착력 향상에 관한 연구)

  • Park, Sungjun;Song, Jongkwon;Park, Euiyong;Rho, Taeho;Choi, Sunghan
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.4
    • /
    • pp.92-97
    • /
    • 2019
  • A study was conducted to improve the adhesion of propellant, liner,and insulation. Insulation was shown to be more advantageous in improving the adhesion when a barrier coat was applied compared to a bare insulation layer. It was confirmed that the adhesion strength between the insulation and the propellant improves as the thickness of the liner coating increases. The liner was cured for 24 h. If the liner is cured for a long time, it will adversely affect adhesion. Adhesion is also improved when a bonding agent is applied. As the bonding agent content increases, the adhesion improves. There is a change in the adhesive strength depending on the type of bonding agent used. HX-868 shows slightly more improved adhesion than HX-752.

Mechanical and Electrical Properties of Impact Polypropylene Ternary Blends for High-Voltage Power Cable Insulation Applications (고전압 전력케이블 절연체 응용을 위한 임팩트 폴리프로필렌 기반 3성분계 블렌드의 기계적 및 전기적 특성에 대한 연구)

  • Lee, Seong Hwan;Kim, Do-Kyun;Hong, Shin-Ki;Han, Jin Ah;Han, Se Won;Lee, Dae Ho;Yu, Seunggun
    • Composites Research
    • /
    • v.35 no.3
    • /
    • pp.127-133
    • /
    • 2022
  • Polypropylene (PP) has been received great attention as a next-generation high-voltage power cable insulation material that can replace cross-linked polyethylene (XLPE). However, the PP cannot be used alone as an insulation material because of its high elastic modulus and vulnerability to impact, and thus is mainly utilized as a form of a copolymer with rubber phases included in the polymerization step. In this paper, a soft PP-based blend was prepared through melt-mixing of impact PP, polyolefin elastomer, and propylene-ethylene random copolymer. The elastic modulus and impact strength of the blend could properly be decreased or increased, respectively, by introducing elastomeric phases. Furthermore, the blends showed a high storage modulus even at a temperature of 100℃ or higher at which the XLPE loses its mechanical properties. In addition, the blend was found to be effective in suppressing the space charge compared to the pristine PP as well as XLPE.

Efficiency of insulation layers in fire protection of FRP-confined RC columns-numerical study

  • El-Mahdya, Osama O.;Hamdy, Gehan A.;Hisham, Mohammed
    • Structural Engineering and Mechanics
    • /
    • v.77 no.5
    • /
    • pp.673-689
    • /
    • 2021
  • This paper addresses the efficiency of thermal insulation layers applied to protect structural elements strengthened by fiber-reinforced polymers (FRP) in the case of fire event. The paper presents numerical modeling and nonlinear analysis of reinforced concrete (RC) columns externally strengthened by FRP and protected by thermal insulation layers when subjected to elevated temperature specified by standard fire tests, in order to predict their residual capacity and fire endurance. The adopted numerical approach uses commercial software includes heat transfer, variation of thermal and mechanical properties of concrete, steel reinforcement, FRP and insulation material with elevated temperature. The numerical results show good agreement with published results of full-scale fire tests. A parametric study was conducted to investigate the influence of several variables on the structural response and residual capacity of insulated FRP-confined columns loaded by service loads when exposed to fire. The residual capacity of FRP-confined RC column was affected by concrete grade and insulation material and was shown to improve substantially by increasing the concrete cover and insulation layer thickness. By increasing the VG insulation layer thickness 15, 32, 44, 57 mm, the loss in column capacity after 5 hours of fire was 30%, 13%, 7% and 5%, respectively. The obtained results demonstrate the validity of the presented approach for estimation of fire endurance and residual strength, as an alternative for fire testing, and for design of fire protection layers for FRP-confined RC columns.

Effect of Glass Fiber-Reinforced Polymer (GFRP) Shear Connector's Shape on Inplane Shear Strength of Insulated Concrete Sandwich Panels (유리섬유복합체를 사용한 전단연결재 형상에 따른 중단열 벽체의 면내전단내력)

  • Jang, Seok-Joon;You, Young-Chan;Kim, Ho-Ryong;Yun, Hyun-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.4
    • /
    • pp.9-17
    • /
    • 2013
  • This paper describes an experimental program to investigate the shear behavior of insulated concrete sandwich panels (CSPs) with different types of GFRP shear connector. The study included testing of 13 insulated CSP specimens with two types of surface conditions for extruded polystyrene (XPS) insulation and various shapes of shear connectors. All specimens were loaded in direct shear by means of push-out and were consist of three concrete panels, two insulation layer and four rows of GFRP shear connectors. Load-relative slip between concrete panel and insulation response of CSP specimens has been established through push-out shear test. Test results indicate that the surface condition of insulation has a significant effect on the bond strength between concrete panel and insulation. The specimen used XPS foam with 10mm deep slot shows higher bond strength than those used XPS foam with meshed surface. Corrugated GFRP shear connectors show equivalent strength to grid GFRP shear connectors. Cross-sectional area and embedded length of shear connector have a notable effect on overall response and inplane shear strength of the CSP specimens.

Temperature History of Concrete According to the Covering Method of Double Layer Bubble Sheet (이중버블시트의 포설방법에 따른 콘크리트의 온도이력특성)

  • Baek, Dae-Hyun;Son, Ho-Jung;Hong, Seak-Min;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05a
    • /
    • pp.71-72
    • /
    • 2010
  • The study is compared temperature history and strength of concrete followed by covering method of insulation curing of cold weather concrete with double bubble sheet. The results were as follows. First of all, in temperature history of concrete, the internal temperature of concrete fell down to $0^{\circ}C$ before/after 60 hours, having nothing to do with covering method. The study could see that, when sheet was isolated, it fell down to low temperature quickly in early curing. When the study measured compressive strength of core specimen, there were no large differences among placing methods. However, compressive strength fell down in all ages when sheet was isolated.

  • PDF

A Study on the Reduction of Floor Impact Sound according to the Thickness and Stiffness of Slab (슬래브 두께 및 강도의 변화에 따른 바닥 충격음 특성에 관한 연구)

  • Park, In-Sun;Kim, Tae-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.276-277
    • /
    • 2012
  • This study was carried out in the laboratory of the reverberation. A total of six specimens were fabricated depending on the thickness and strength. Floor impact sound insulation performance was measured in 1/3 octave band center frequency. The results of this study are as follows. Although some differences in the frequency band, the result of evaluating the weight impact sound blocking performance as the thickness increases, the floor impact sound insulation performance is improved. In addition, to increase the strength of the slab, even if the block impact sound performance is improved.

  • PDF

A strength monitoring with wireless sensor network based on equivalent age method depending on the usage of the insulated formwork during the winter period (동절기 단열 유·무 거푸집을 설치한 슬래브 콘크리트에서 등가재령 기반의 무선센서 네트워크를 이용한 강도 모니터링)

  • Lee, Young-Jun;Lee, Hyuk-Ju;Hyeon, Seung-Yong;Seo, Hang-Goo;Lee, Sang-Woon;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.167-168
    • /
    • 2018
  • In this research, the feasibility of wireless senor for compressive strength evaluation was checked by applying on the actual apartment construction site with insulation formwork during winder period. As a result, there was no significant problem on monitoring the compressive strength of the concrete with the sensor. Thus it is considered that the suggested method can be an efficient method for the quality control at the construction site.

  • PDF

A study on insulation Characteristics of XLPE by various additives (다양한 첨가제에 따른 가교폴리에틸렌의 절연특성 분석)

  • Song, Sang-Min;Kim, Gyu-Sik;Son, Won-Keun;Ryu, Boo-Hyung;Park, Soo-Gil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.193-196
    • /
    • 2001
  • XLPE is occasionally happened to deteriorate cable insulation characteristics. It is happened to do a breakdown state by the degradation of electrical characteristic and electrical breakdown strength. I prepared TR-XLPE (Tree-Retardant XLPE) as adding various additives to prevent its states. Various additives are treeing retardants, anti-oxidants. Treeing retardants three kinds of aromatic compounds as adding each additive. Anti-oxidants use quinone compound and cresol compound as adding each additive. In order to observe each electrical characteristics, I measured breakdown strength, relative dielectric constant$({\varepsilon}_r)$, dielectric loss tangent$(tan{\delta})$. TR-XLPE specimens as adding treeing retardants and anti-oxidants enhance breakdown strength, ${\varepsilon}_r$, $tan{\delta}$ than pure XLPE.

  • PDF