• 제목/요약/키워드: Insulation Panel

검색결과 220건 처리시간 0.028초

목탄충진 목재판넬의 특성 (Properties of Charcoal-Packed Wood Panel)

  • 김남훈;황원중;권구중;권성민
    • 한국가구학회지
    • /
    • 제15권1호
    • /
    • pp.9-16
    • /
    • 2004
  • Five type boxes manufactured from cement(A), wood panel(B), charcoal-packed wood panel(C), plywood panel(D) and charcoal-packed plywood panel(E) were prepared. Relationship of preservation characteristic of strawberry and relative humidity, and properties of thermal and sound insulations in the boxes were examined. During the experimental duration, relative humidity in the cement box was highest and lowest in the charcoal-packed wood panel box. Weight loss of strawberry was greatest in charcoal-packed wood panel box and very little in cement box. In the boxes with charcoal-packed wood panel box and very little in cement box. In the boxes with charcoal, strawberry was preserved for 10 days without getting mold, but in cement box it was covered with mold in 3 days. The charcoal-packed boxes showed higher thermal insulation property than the cement box. There were no significant differences in the property of sound insulation among the 5 type boxes. Consequently, it is suggested that charcoal-packed wood panels can be used for a better ecomaterial.

  • PDF

차세대 고속철도 차량 측면 적층재의 차음성능 (Sound Insulation Performance of the Side Layered Panels in the Next Generation High Speed Train)

  • 이중혁;이호진;박인석;김석현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 추계학술대회 논문집
    • /
    • pp.457-462
    • /
    • 2011
  • The sidewall of the HEMU-400x consists of two parts. One is the multi-layered structure including aluminium extruded panel and the other is the double glazed window. When the train runs in a tunnel, the equivalent sound insulation performance of the side wall significantly influences the internal noise levels. In aspect of the sound insulation strategy, it is important to make two parts have similar performance. In this study, the intensity sound transmission loss (ITL) is measured on the specimens of the two parts. Mass law deviation (MLD) is considered in order to compare the sound insulation performance of the two parts in respect of the weight. Contribution of each part to the sound insulation is analyzed and the sound insulation strategy is investigated to reduce the interior noise.

  • PDF

금속진공단열패널의 심재용 기포콘크리트의 성능에 관한 연구 (A Study on the Performance of Foamed Concrete for Cores Material of Metal Vacuum Insulation Panel)

  • 홍상훈;김봉주
    • 한국건축시공학회지
    • /
    • 제20권5호
    • /
    • pp.417-423
    • /
    • 2020
  • 건축물의 에너지 소비 중 40%인 냉·난방을 줄이기 위해 외피 단열향상이 중요시되고 있다. 이에 기존 단열재를 개선하기 위해 진공단열패널VIP(Vacuum Insulation Panel)을 건축물에 적용하기 위한 연구가 진행되고 있다. 하지만 VIP는 보수보강이 불가능해 이를 개선한 금속진공단열패널을 고려하였다. 금속진공단열패널의 심재는 진공압력을 버티고, 낮은 열전도율을 가져야 하므로 기포콘크리트를 채택하였다. 하지만 예비 실험을 통해 기포의 양이나 성질에 의해 0.001torr에 도달하는 시간이 다른 것을 확인하였다. 이러한 영향은 기포제의 종류 및 기포 슬러리 밀도 등에 의해 진공도달시간이 달라질 것이라 판단하여 최적 기포콘크리트 조건이 필요하다. 따라서 본 연구에서는 금속진공단열패널의 심재인 기포큰크리트의 기포제 종류 및 기포 슬러리 밀도에 따라 진공도달시간 및 열전도율 변화를 측정하여 심재로 적용 가능한 기초적 자료를 제시하는 것을 연구목적으로 한다.

냉장고 진공단열재 성능진단을 위한 열유속계 위치에 관한 연구 (A Study on the Heat Flux Meter Location for the Performance Test of a Refrigerator Vacuum Insulation Panel)

  • 하지수
    • 설비공학논문집
    • /
    • 제25권8호
    • /
    • pp.471-476
    • /
    • 2013
  • The present study has been carried out to elucidate the optimal method for the performance test of a refrigerator vacuum insulation panel (VIP), by using numerical heat transfer analysis. Three locations of heat flux meter have been tested, for deriving the best test method to clarify the normal or the abnormal condition of the vacuum insulation panel in a refrigerator. The first location of the heat flux sensor is at the same place as the heater, the second one is at the nearby side location of the heater and the third one is at the opposite side location of heater in the refrigerator. The heat flux and $1/q^{{\prime}{\prime}^2}$ or $q^{{\prime}{\prime}^4}$ were calculated for the cases with the normal VIP, and with the abnormal VIP, and their differences analyzed. From the present study, the first and the second method had a mere difference characteristics of heat flux and $1/q^{{\prime}{\prime}^2}$ or $q^{{\prime}{\prime}^4}$, between the cases with the normal or the abnormal VIP. The magnitude of the heat flux after 300sec had a great difference between the cases with the normal or abnormal VIP for the third method, and it could be considered the most optimal method to test the performance of a refrigerator vacuum insulation panel.

코너 특정점 기반의 영상분석을 활용한 진공단열재 결함 검출 (Defect detection of vacuum insulation panel using image analysis based on corner feature detection)

  • 김범수;양정현;김연원
    • 한국표면공학회지
    • /
    • 제55권6호
    • /
    • pp.398-402
    • /
    • 2022
  • Vacuum Insulation Panel (VIP) is an high energy efficient insulation system that facilitate slim but high insulation performance, based on based on a porous core material evacuated and encapsulated in a multi-barrier envelope. Although VIP has been on the market for decades now, it wasn't until recently that efforts have been initiated to propose a standard on aging testing. One of the issues regarding VIP is its durability and aging due to pressure and moisture dependent increase of the initial low thermal conductivity with time. It is hard to visually determine at an early stage. Recently, a method of analyzing the damage on the a material surface by applying image processing technology has been widely used. These techniques provide fast and accurate data with a non-destructive way. In this study, the surface VIP images were analyzed using the Harris corner detection algorithm. As a result, 171,333 corner points in the normal packaging were detected, whereas 32,895 of the defective packaging, which were less than the normal packaging. were detected. These results are considered to provide meaningful information for the determination of VIP condition.

샌드위치 복합소재가 적용된 틸팅 차량의 단열 특성 평가 연구 (Evaluation of the Property of adiabatic Insulation for TTX Train with Sandwich Composite bodyshell)

  • 이상진;오경원;정종철;조세현;서승일
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.251-256
    • /
    • 2005
  • This study was performed the heat transportation ratio of three types of the following sandwich panel by KS F 2278(2003) ; Type ${\sharp}1$ : Carbon/epoxy Aluminum Honeycomb and Balsa Core Sandwich Panel(Thickness : 37mm), Type ${\sharp}2$ : Carbon/epoxy Aluminum Honeycomb Core Sandwich Panel(Thickness : 57mm), and Type ${\sharp}3$ : Carbon/epoxy Aluminum Honeycomb Core Sandwich Panel(Thickness : 37mm). Also was performed the heat transportation of next three types of the following sandwich panel by KS F2277(2002) ; Type ${\sharp}4$ and ${\sharp}5$ : 27mm, and 35mm thick-Aluminum Honeycomb Sandwich Panels, and Type ${\sharp}6$ : 27mm thick-Foaming Aluminum Sandwich Panel. It is the larger area between the skin and core, the heat transportation ratio is the higher, and when it is composed of the hybrid composite structure, good insulation property was shown.

  • PDF

틸팅 열차용 허니콤 복합판재의 투과손실 (Transmission loss of Honeycomb Composite Panel of the Tilting Train)

  • 김석현;임봉기;김재철;장윤태
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1088-1091
    • /
    • 2009
  • In a tilting train, aluminium honeycomb composite panel is used for the high speed and light weight. Side wall of the tilting train includes the composite panel of carbon fiber, aluminium honeycomb and epoxy fiber as a main structure. In this study, we measure the transmission loss (TL) of the honeycomb composite panel and analyse the sound insulation performance by using the orthotropic plate model. We investigate experimentally how the air gap, plywood and glass wool improve the sound insulation performance of the composite panel. The purpose of the study is to provide practical information for the improvement of TL of the honeycomb composite panel used for the tilting train.

  • PDF

단열재 개선을 통한 PKG-A Water Jet Room 온도저감 연구 (A Study on the Internal Temperature Reduction of PKG-A Water-jet-room by Substituting Heat Insulation Materials)

  • 정영인;최상민
    • 품질경영학회지
    • /
    • 제47권3호
    • /
    • pp.425-435
    • /
    • 2019
  • Purpose: The purpose of this study was to resolve the Naval ship's Local Operation Panel(LOP) malfunction problems which caused by overheating in summer season and dispatching to equatorial regions. Methods: Instead of using dual type heat insulation materials(consist with ceramic wool and glass wool), aerogel heat insulation materials were used for decreasing heat emissions from gas-turbine heat waste steam pipes passing water-jet- room. Experiment and Computational analysis of heat flow were conducted to analyze the internal room temperature changes. Results: The results of this study are as follows; The aerogel heat insulation materials suppress heat emission more efficiently than dual type insulation materials. The cold surface temperature of insulation was far more decreased and internal room, LOP surface temperature also showed significant results too. Conclusion: The substituted heat insulation materials appeared remarkable performance in decreasing room temperature that it could be used for suppressing the LOP overheatings and malfunctions.

복합자재 콘칼로리미터평가방법에 대한 연구 (A Study on the Cone Calorimeter Evaluation Method of Sandwich Panels)

  • 박정우;조남욱
    • 한국화재소방학회논문지
    • /
    • 제31권6호
    • /
    • pp.74-82
    • /
    • 2017
  • 유기단열재를 사용한 샌드위치패널(복합자재) 건축물 화재는 소화가 어려우며, 가연성 심재를 통한 빠른 화재 확산으로 화재 시 피해가 크다. 샌드위치패널은 양면이 불연재로 되어있고, 불연재 사이에 심재인 단열재로 이루어져 있다. 단열재는 유기단열재와 무기단열재가 사용되고 있으며, 유기단열재가 무기단열재에 비하여 약 80% 이상 사용되고 있다. 유기단열재는 무기단열재에 비하여 경제적인 장점이 있지만 화재에 취약하다는 단점을 가지고 있기 때문에 샌드위치패널 화재 시 일반화재에 비하여 피해가 크다. 가스유해성시험의 경우 복합자재의 심재 위험성을 측정하기 위해 패널에 지름 25 mm 크기 3개의 원형 천공을 하여 시험하지만 콘칼로리미터 시험은 샌드위치패널 형태 그대로 시험을 진행한다. 본 연구에서는 KS F ISO 5660-1 콘칼로리미터 시험에서 복합자재의 경우 불연재인 표면에 가열한 경우와 천공을 통한 심재 노출 시험 및 심재에 직접가열 시 발생하는 화재의 위험성을 측정하였다. 시험에 사용된 유기단열재는 일반 EPS와 난연 EPS를 사용하였으며, 시험체 구성은 샌드위치패널, 천공된 샌드위치 패널, 심재의 3가지 형태로 시험을 진행하였다. 본 연구의 목적은 콘칼로리미터 시험 시 복합자재 심재의 화재 위험성을 평가하는 방안을 제시하고자 하였다.

저회를 이용한 경량패널의 현장 차음성능에 관한 실험 연구 (An experimental study on the field sound insulation performance of the light weight concrete panel using bottom ash)

  • 정진연;정갑철;이병권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.65-69
    • /
    • 2007
  • Recently, the method of the apartment building design is changing from wall type to moment structure. Because of this reason, dry wall systems are used plentifully. This study examines the sound insulation performance of the light weight concrete panel using bottom ash. There is the difference of airborne sound isolation between laboratory and field test. For the purpose of searching deviation, we use the prediction tool(Insul 6.0). First, we calculated the prediction data and measured the sound isolation in the wall at the lab. Then, we measured it in the field and compared them. At the base of these datum, we measured the difference.

  • PDF