• Title/Summary/Keyword: Insulation Material

Search Result 1,324, Processing Time 0.032 seconds

Assessment of Insulation Condition in Large Transformers (대형변압기 절연상태 평가)

  • Kim, Hee-Dong;Kong, Tae-Sik;Lee, Young-Jun;Park, Jae-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.499-502
    • /
    • 2004
  • In order to detect of insulation problems an early, transformer has to be performed the several tests. The ac current and tan6 of transformer winding insulation were investigated by Schering bridge. Partial discharge(PD) tests are used to evaluate the insulation condition of transformer. The moisture content measurement was conducted using RVM(recovery voltage meter). The RVM test can show that the problem is affecting the paper insulation of transformer. The value of moisture content was 2.3% in main transformer. The insulations of four transformers were judged to be in good condition.

  • PDF

Properties of EMNC According to Addition Contents Variation for Nanosilica (2) -For Mechanical, Electrical Properties (나노 실리카 충진함량 변화에 따른 EMNC의 특성 연구 (2) -기계적, 전기적 특성 중심으로-)

  • Park, Jae-Jun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.11
    • /
    • pp.886-894
    • /
    • 2012
  • In order to develop electrical insulation materials, epoxy-nanosilica-microsilica mixture composites (ENMC) was synthesized, and mechanical properties such as their tensile and flexural strength, and AC insulation breakdown strength were investigated. Properties of mechanical strength and AC insulation breakdown strength are analyzed as scale and shape parameter with respect to weibull plot. Their tensile and flexural strength, AC insulation breakdown strength were compared original epoxy or EMC to ENMC. The 4 phr nano-silica addition and the 65 wt% micron-silica mixture composite (ENMC) was found to have the highest tensile and flexural strength. In the tensile strength was improved 29%, and flexural strength was improved 60.9% higher than those of the original epoxy. In the insulation breakdown strength, ENMC_4 phr was improved 17% and ENMC_5 phr was improved 15.8% higher than those of the EMC.

Electrical Properties of Liquid Insulation as a Function of Temperature (온도에 따른 액체 절연유의 전기적 특성 )

  • Tae-Hee Kim;Yong-Sung Choi
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.3
    • /
    • pp.280-285
    • /
    • 2024
  • In this paper, the electrical properties of liquid insulating oil were analyzed by changing the ambient temperature change at 10℃ in-tervals from 0℃ to 30℃ through an insulation breakdown experiment in order to analyze the insulation performance of liquid in-sulating oil that varies according to temperature changes. As a result, it was confirmed through experiments that the lower the am-bient temperature, the higher the insulation breakdown voltage, depending on both the electrode shape and the electrode interval, and it was determined that the lower the ambient temperature, the higher the insulation performance of the liquid insulating oil.

Comparative Analysis on Insulation Performance of Traction Motors for Hybrid Vehicles (하이브리드 차량용 견인전동기의 절연성능 비교분석)

  • Choi, Su-Yeon;Park, Chan-Yong;Kim, Sung-Wook;Park, Dae-Won;Kil, Gyung-Suk;Lee, Kang-Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.12
    • /
    • pp.1124-1129
    • /
    • 2008
  • The object of this paper is to acquire the data related to insulation evaluation of hybrid vehicle traction motors. We made a comparative analysis on Insulation Resistance (IR), Dielectric Absorption Ratio (DAR), and Polarization Index (PI) of the motor stators. The experiment was carried out according to IEEE Std. 43 and IEC 60085-1 for insulation resistance test standard of rotating machinery. Test voltage of 500 V was applied between a phase and the enclosure. The IR and the DAR of used motors were lower than those of new ones. The DAR and the PI were $0.92{\sim}1.02$ and $0.74{\sim}1.1$, respectively and the result did not meet the recommendation basis 2 for insulation level H. From the experimental results, we could prepare parameters and basis for insulation evaluation of the traction motor stator by the comparative analysis of short-time insulation resistance changes, DAR and PI.

Properties of Electrical Performance on Stator Coil of Traction Motor by Accelerated lest using Transient Surge (과도서지를 이용한 가속열화 시험법에 따른 견인전동기 고정자 코일의 전기적 특성 변화)

  • 박현준;장동욱;이길헌;최종선;김저우
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.9
    • /
    • pp.783-789
    • /
    • 2003
  • The winding problems of traction motor are the major determinant of motor's life. The root cause of winding failure is gradual deterioration of the insulation due to thermal, electrical, mechanical and environmental stresses. The aging of the insulation reduces the electrical and mechanical strength of the insulation. At same point, a voltage surge or mechanical shock from a traction motor start will fracture or break down the insulation. To achieve the expected life usually requires extensive laboratory evaluation of the insulation systems and the use of accelerated aging tests. There are several nondestructive test available for checking, the condition of motor insulation, the probable extent of aging, and the rate of which aging is taking place. So the insulation characteristics of stator coil were each analyzed by measurement of dielectric loss(tan$\sigma$), capacitance and partial discharge. The method of diagnosis is able to analyze the insulation condition and evaluate the life of the traction motor.

A Study on the Cone Calorimeter Evaluation Method of Sandwich Panels (복합자재 콘칼로리미터평가방법에 대한 연구)

  • Park, Jung-Woo;Cho, Nam-Wook
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.74-82
    • /
    • 2017
  • Fires in buildings built using sandwich panels are difficult to extinguish, and the damage caused by the fire spreading through the inner core material is extensive. Sandwich panels consist of a nonflammable material on both sides of an insulation material. The types of insulation material include organic and inorganic insulation materials, but the former are used in more than 80% of the case. Organic insulation is economically advantageous compared to inorganic insulation, but it is vulnerable to fire. Therefore, the damage caused by sandwich panel fires is higher than that for general fires. In the case of the noxious gas analyzer test, the panel is tested with three round holes having a diameter of 25 mm, in order to determine the risk of the core material, but the cone calorimeter test is carried out using a sandwich panel. In this study, the cone calorimeter test was conducted to examine the fire risk of the composite material when heated on a nonflammable surface, exposed to the core material through a hole, and heated directly the core material. The type of organic insulation employed was flame retardant EPS (Expanded Polystyrene), and the test specimens were tested in three types of sandwich panel, a perforated sandwich panel and single core material. The purpose of this study is to propose a method of measuring the fire risk of the core materials of composite materials using the cone calorimeter test.

Making the Insulation Mortar Mixed with Waste Paper and Sawdust (종이와 톱밥을 혼입한 단열 모르타르 재료 개발에 관한 연구)

  • Lee, Seung-Young;Son, Ki-Sang
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.3
    • /
    • pp.78-82
    • /
    • 2010
  • This study is to test insulation mortar mixed with wastepaper and sawdust to find out its insulation performance. Therefore, wastepaper and sawdust have been added to normal mortar. They are analyzed for the above purpose using compressive strength and insulation performance. It is found that the more wastepaper and sawdust will be mixed, the lower heat conductivity will be taken. Wastepaper and sawdust mixture will be more 2.0% then the insulation mortar quality can be compatible with the 3rd kind of the standard. Optimal mixture for insulation will be wast paper:sawdust=4:6. Cohesive test of materials showed that test material has stronger than stand are $0.10N/mm^2$. It is satisfactory the test result showed a range of $0.12{\sim}0.15N/mm^2$ from the test result. Optimal mixture of wastepaper and sawdust have been found out from the study comprehensively, exclusive of the proportion of wastepaper:sawdust = 8:2. It is thought that standard of length deformation; 0.5% is reasonable. This means that deformation of mortar itself can be considered. But it is also Shown that water mixture has also been sharply changed at first flow test. Therefore, it is thought that absorbed water content in the material gave considerable effect to variation rate.

Evaluation of mechanical and thermal properties of insulation materials for HTS power devices at liquid nitrogen temperature

  • Shin, Hyung-Seop;Diaz, Mark Angelo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.2
    • /
    • pp.53-57
    • /
    • 2017
  • In superconducting power devices including power cables in which high temperature superconducting (HTS) tapes are utilized, a reliable electrical insulation should be achieved for its maximum performance. For an efficient design of HTS superconducting devices, a comparative evaluation of the mechanical and thermal propperties for various insulation materials at cryogenic temperatures is required. Especially, in the process of the property evaluation of the sheet-shaped insulation materials, anisotropy according to the machining direction should be considered because the mechanical and thermal properties are significantly influenced by the sample orientation. In this study, the cryogenic thermal and mechanical properties of various insulation material sheets such as PPLP, Cryoflex, Teflon, and Kapton were determined considering sample orientation. All samples tested at cryogenic temperature showed significantly higher tensile strength as compared with that of room temperature. The ultimate tensile strength at both temperature conditions significantly depended upon the sample orientation. The thermal properties of the insulation materials exhibited a slight difference among samples depending on the orientation: for the PPLP and Cryoflex, the CD orientation showed larger thermal contraction up to 77 K as compared to the MD one. MD samples in PPLP and Cryoflex showed a lower CTE and thermal contraction which made it more promising as an insulation material due to its comparable CTE with HTS CC tapes.

Dielectric Insulation properties of Double Pancake coil type HTS Transformer (Double Pancake형 고온초전도 변압기의 전기적 절연 특성)

  • 백승명;정종만;이정원;김상현
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.494-498
    • /
    • 2002
  • HTS transformer experimentally. High temperature superconductors can only be applied against an engineering specification that has to be determined for each particular application form the design requirements for economic viability and for operation margins in service. High temperature superconducting(HTS) power apparatus are very promising candidates for application. Especially, these advantages make superconducting transformers very promising candidates for application in electrical power engineering and locomotives. In order to realize the HTS transformer, it is necessary to establish the high voltage insulation technique in cryogenic temperature. So far, insulation research of Pancake type HTS transformer is lacking nothing but insulation research of . solenoid type transformer consisted. Therefore, the composite insulation of double pancake coil type transformer are described and ac breakdown voltage characteristics of liquid nitrogen(LN$_2$) under HTS pancake coil electrode made by Bi-2223/Ag are studied. Breakdown in LN$_2$ is dominated electrode shape and distance. The relation between surface flashover voltage is considered for FRP. This research presented basis information of electrical insulation design for double pancake coil type HTS transformer.

  • PDF

Dielectric Insulation Properties of Double Pancake Coil Type HTS Transformer (Double Pancake Coil형 고온초전도 변압기의 전기적 절연 특성)

  • 백승명;정종만;이현수;한철수;김상현
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.2
    • /
    • pp.151-156
    • /
    • 2003
  • High temperature superconductor can only be applied against an engineering specofication that has to be determined for each particular application form the design requirements for economic viability and for operation margins in service. However, in order to realize the HTS transformer, it is necessary to establish the high voltage insulation technique in cryogenic temperature. Therefore, the composite insulation of double pancake coil type transformer are described and AC breakdown voltage characteristics of liquid nitrogen(LN$_2$) under HTS pancake coil electrode made by Bi-2223/Ag are studied. The Breakdown of LN$_2$ is dominated electrode shape and distance. The influence of pressure on breakdown voltage is discussed with th different electrode. For the electrical insulation design of turn-to-turn insulation for the HTS transformer, we tested breakdown strength of insulation sheet under varying pressure. And we investigated surface flashover properties of LN$_2$ and complex conition of cryogenic gaseous nitrogen(CGN$_2$) obove a LN$_2$ surface. The surface voltage of GFRP was measured as a function of thickness and electrode distance in LN$_2$ and complex condition of CGN$_2$ above a LN$_2$ surface. this research presented information of electrical insulation design for double pancake coil(DPC) type HTS transformer.