• Title/Summary/Keyword: Insulation Material

Search Result 1,332, Processing Time 0.023 seconds

Insulation Properties of Epoxy Resin to Elastomer Contents for Power Electrical Machine according to Moisture Absorption (전력기기용 탄성형 에폭시의 흡습에 따른 절연 특성)

  • Kim, Seok-Jae;Park, Seong-Hui;Jeon, Young-Sik;Kang, Seong-Hwa;Park, Dae-Hee;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.297-300
    • /
    • 2004
  • In this paper, we investigated insulation property of epoxy resin which includes elastomers to improve mechanical property, as varied to additive elastomer contents and to moisture absorption. There are four samples with 5[phr], 10[phr], 15[phr] and 20[phr]. we experimented to acquire insulation property(absorption rate, dissolution rate, apparent rate) and electrical property(perittivity, $tan\delta$, BDV) during respectively the time such as 6[h], 12[h], 18[h], 24[h] for moisture absorption. According to the experimental results, it is appeared that when the additive elastomer contents are increasing or when specimens remain more moisture, absorption rate, dissolution rate, permittivity and $tan\delta$ are slightly increasing but apparent rate and BDV(break-Down Voltage) strength are decreasing in particular, elastomer content [20]phr appeared remarkedly the more increase or decrease than others.

  • PDF

Study of Liquid Crystal Alignment and Polarization-dependence on organic surface with slanted ion beam irradiation (유기절연막으로의 경사진 이온빔조사가 유기막 표면에서의 편광발생과 액정배향에 미치는 영향에 관한 연구)

  • Han, Jeong-Min;Choi, Dae-Sub;Hwang, Jong-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.15-16
    • /
    • 2010
  • We used Brewster's Law to examine the mechanism of liquid crystal (LC) alignment on an organic insulation layer when subjected to ion-beam irradiation. Brewster's Law implies that the maximum rate polarized rayon a slanted insulation layers on the substrate and it illustrates the dependence of polarization and themechanical structure on the ion beam irradiation process. The pretilt angle of nematic LCs on the organic insulation surface was about $1.13^{\circ}$ for an ion beam exposure of $45^{\circ}$ for 1 minute at 1800eV. This shows the dependence of LC alignment on the polarization ratio in a slanted organic insulation layer. We also discussed the electro-optical characteristic of twisted nematic (TN) LCD using ion beam irradiation on organic overcoat layer.

  • PDF

The Electric Field Distribution Characteristic Of Outdoor ECT Using the Preventive Diagnostic Sensor (예방진단센서가 내장된 옥외용 ECT의 전계분포특성)

  • Lee, Han-Joo;Cho, Sung-Hoon;Jung, Eui-Hwan;Yoon, Jae-Hoon;Lim, Kee-Joo;Kang, Sung-Hwa
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.27-27
    • /
    • 2010
  • The exact partial discharge pulse should be measured in order to estimate the discharge source in the solid insulation and diagnose the degree of deterioration. Partial discharges generated in the insulation occur in the internal voids or at the edge of the insulation, have unique characteristics following the type and location. When external voltage is applied, Partial discharges occurred in the restrictively presented voids increase the quantity of electrical charge at the discharge onset voltage. The discharge characteristics have remained constant as space is filled by the impurity such as a compound of gases accompanied with discharge. In this study, How to design the insulation about the problems of the built-in diagnostics in the transformer is discussed by the interpretation of electric field.

  • PDF

Study on the Electrical Insulation of Current Lead in the conduction-cooled 1-2kV Class High-Tc Superconducting DC Reactor (전도냉각되는 1-2kV급 고온초전도 직류리액터 전류도입부의 전기적 절연에 대한 연구)

  • 배덕권;안민철;이찬주;정종만;고태국;김상현
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.30-34
    • /
    • 2002
  • In this Paper, Insulation of current lead in the conduction-cooled DC reactor for the 1.2kV class 3 high-Tc superconducting fault current limiter(SFCL) is studied. Thermal link which conducts heat energy but insulates electrical energy is selected as a insulating device for the current lead in the conduction-cooled Superconducting DC reactor. It consists of oxide free copper(OFC) sheets, Polyimide films, glass fiberglass reinforced Plastics (GFRP) plates and interfacing material such an indium or thermal compound. Through the test of dielectric strength in L$N_2$, polyimide film thickness of 125 ${\mu}{\textrm}{m}$ is selected as a insulating material. Electrical insulation and heat conduction are contrary to each other. Because of low heat conductivity of insulator and contact area between electrical insulator and heat conductor, thermal resistance of conduction-cooled system is increased. For the reducing of thermal resistance and the reliable contact between Polyimide and OFC, thermal compound or indium can be used As thermal compound layer is weak layer in electrical field, indium is finally selected for the reducing of thermal resistance. Thermal link is successfully passed the test. The testing voltage was AC 2.5kVrms and the testing time was 1 hour.

Characteristics of Insulation Diagnosis and Failure in 6.6 kV Motor Stator Windings (6.6 kV 전동기 고정자 권선의 절연진단과 절연파괴 특성)

  • Kim, Hee-Dong;Kong, Tae-Sik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.4
    • /
    • pp.309-314
    • /
    • 2012
  • To assess the condition of stator insulation, nondestructive and overpotential tests were performed on four high voltage motors. The stator windings under these tests have nominal ratings of 6.6 kV. After completing nondestructive tests, the AC overvoltage applied to the stator windings was gradually increasing until insulation failure in order to obtain the breakdown voltage. No. 1, No. 2, No. 3 and No. 4 of 6.6 kV motors failed near rated voltage of 18.4 kV, 19.8 kV, 19.7 kV and 21.7 kV, respectively. The breakdown voltage of four motors was higher that expected for good quality coils(14.2 kV) in 6.6 kV motors. Almost all of failures were located in a line-end coil at the exit from the core slot. The breakdown voltages and the types of defects showed strong relation to the stator insulation tests such as in the case of AC current, dissipation factor($tan{\delta}$) and partial discharge magnitude.

Study on the AC Interfacial Breakdown Properties in the Interface between toughened Epoxy and Silicone Rubber (Toughened 에폭시와 실리콘고무 계면의 교류 절연파괴 현상에 관한 연구)

  • 박우현;이기식
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.12
    • /
    • pp.1079-1084
    • /
    • 2002
  • Because complex insulation method is used in EHV(extra high voltage) insulation systems, macro Interfaces between two different bulk materials which affect the stability of insulation system exist inevitably. Interface between toughened epoxy and silicone rubber was selected as a interface in EHV insulation systems and tested AC interfacial breakdown properties with variation of many conditions to influence on electrical Properties, such as interfacial pressure, roughness and oil. Specimen was designed to reduce the effect of charge transport from electrode in the process of breakdown and to have the tangential electrical potential with the direction of the interface between epoxy and silicone rubber by using FEM(finite elements method). It could control the interfacial pressure, roughness and viscosity of oil. From the result of this study, it was shown that the interfacial breakdown voltage is improved by increasing interfacial Pressure and oil. In particular, the dielectric strength saturates at certain interracial Pressure level. The decreasing ratio of the interfacial breakdown voltage in non-oiled specimen was increased by the temperature rising, while oiled specimen was not affected by temperature.

Electrical Insulation Characteristics of Insulators in Cryogenic Liquid for a HTS Apparatus (고온초전도 기기를 위한 극저온 액체 중 절연물의 전기적 특성)

  • Baek, Seung-Myeong;Kwag, Dong-Soon;Cheon, Hyeon-Gweon;Choi, Jae-Hyeong;Kim, Sang-Hyun;Kim, Hyun-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.263-264
    • /
    • 2006
  • For practical electrical insulation design of high temperature superconducting (HTS) power apparatuses, knowledge of the dielectric behavior of insulators in cryogenic liquid such as liquid nitrogen ($LN_2$) is essential. So in this paper, we discussed experimental investigations of breakdown and V-t characteristics of several insulators such as Kapton and glass fiber reinforced plastic (GFRP) that are candidates of insulator for HTS apparatus in cryogenic liquid. And we investigated the degradation of these insulation samples after breakdown with the microscope and SEM photograph. Moreover, survival and hazard analysis were performed.

  • PDF

A Study on the Acoustic Detection of Partial Discharges in Insulation Oil (유중 부분방전의 음향검출에 관한 연구)

  • Kil, Gyung-Suk;Kim, Sung-Wook;Park, Dae-Won;Kim, Sun-Jae;Song, Jae-Man
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.1
    • /
    • pp.53-60
    • /
    • 2010
  • This paper dealt with the acoustic detection of partial discharge (PD) in insulation oil for insulation diagnostics of oil immersed transformers. Electrode systems such as needle to plane, plane to plane, and floating were fabricated to simulate some defects in transformers. A wide band acoustic emission(AE) sensor with the frequency ranges of 100 kHz~1 MHz and a narrow band AE sensor with the resonant frequency of 140 kHz were used in the experiment. Also, a decoupler and an amplifier were designed to detect and amplify the acoustic signal only. The decoupler separates acoustic signal from DC source without any distortion, and the amplifier has the gain of 40 dB in frequency ranges of 11 kHz~4 MHz. In the experiment, frequency components and propagation characteristics of acoustic signal were analyzed, and an algorithm of positioning of PD occurrence by the time difference of arrival was proposed. From the results, the frequency components of the acoustic signal exist from 50 kHz to 200 kHz and the positioning error of PD calculated by three AE sensors was within 1%.

Study on Current Conditioning Process for Improving Withstand Voltage Performance of Vacuum Interrupter (진공인터럽터의 내전압 성능 향상을 위한 전류컨디셔닝 기법 연구)

  • Cha, Young-kwang;Lee, IL-Hoi;Jeon, Ki-Beom;Jang, Ji-Hoon;Ju, Heung-Jin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.5
    • /
    • pp.480-487
    • /
    • 2022
  • As a process to improve the insulation performance of VIs (Vacuum Interrupters), AC voltage conditioning is generally adopted by many manufacturers. Although the insulation performance is enhanced easily with AC Voltage conditioning, it has limitations when high recovery voltage is required due to high voltage rate or capacitive current switching. In particular, impurities such as oxides segregated on the electrode surface can be removed not by the energy level of the voltage conditioning but by the higher energy level achieved by the current conditioning process In this article, the current conditioning was carried out in various conditions and its validity was examined. The current conditioning was processed by changing the amplitude of applied current, arc time, the number of tests, and frequency. The insulation performance and the status of contact surface were checked as well. We concluded that as the applied charge quantity and the conditioning coverage area increase, the conditioning effect is much higher.

Effect of Ambient Temperature on Insulation Lifetime of Winding Coil Prepared with Polyamideimide/Nanosilica Enamelled Wire

  • Park, Jae-Jun;Woo, Myung-Ha;Lee, Jae-Young;Hwang, Don-Ha
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.5
    • /
    • pp.297-301
    • /
    • 2016
  • The effects of ambient temperature and diameter on the insulation lifetime of winding coils prepared with polyamideimide (PAI), flexural PAI (nanosilica 5 wt%) and anti-corona PAI (nanosilica 15 wt%) wires were investigated. The winding coils were made of enameled wire with enamel thickness of 30~50 μm. The thickness and width of the rectangular copper wires were 0.77~0.83 mm and 1.17~1.23 mm, respectively. The insulation breakdown lifetime decreased with increasing ambient temperature regardless of wire type and winding coil diameter under an inverter surge of 1.5 kV/20 kHz. The insulation breakdown lifetimes of φ5 mm winding coils at 150, 200, and 250℃ were 11.38, 5.19, and 4.22 min respectively, and those of φ10 mm winding coils at 150, 200, and 250℃ were 11.32, 5.79, and 4.57min respectively. The winding coil diameter had little effect on the insulation lifetime.