• Title/Summary/Keyword: Insulation Form

Search Result 188, Processing Time 0.028 seconds

A Study on the Insulation Degradation Properties for Stator Form-wound Winding of Traction Motors in Urban Transit E.M.U (철도차량용 견인전동기의 형권 고정자 코일에 대한 절연열화 특성 연구)

  • Kim, K.J.;Chae, S.H.;Wang, J.B.;Park, H.J.;Lee, I.W.;Hur, I.G.;Ha, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.452-454
    • /
    • 1999
  • In this paper, sample coils for stator form-wound winding of traction motor were made for the accelerative thermal degradation composed of heat, vibration, moisture and overvoltage. In progress of test periods, diagnosis tests such as insulation resistance, dielectric loss and partial discharge were investigated. Reliability and expected life were evaluated on the insulation system for 200 class traction motor considering various environmental stress.

  • PDF

Dielectric Insulation properties of Double Pancake coil type HTS Transformer (Double Pancake형 고온초전도 변압기의 전기적 절연 특성)

  • 백승명;정종만;이정원;김상현
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.494-498
    • /
    • 2002
  • HTS transformer experimentally. High temperature superconductors can only be applied against an engineering specification that has to be determined for each particular application form the design requirements for economic viability and for operation margins in service. High temperature superconducting(HTS) power apparatus are very promising candidates for application. Especially, these advantages make superconducting transformers very promising candidates for application in electrical power engineering and locomotives. In order to realize the HTS transformer, it is necessary to establish the high voltage insulation technique in cryogenic temperature. So far, insulation research of Pancake type HTS transformer is lacking nothing but insulation research of . solenoid type transformer consisted. Therefore, the composite insulation of double pancake coil type transformer are described and ac breakdown voltage characteristics of liquid nitrogen(LN$_2$) under HTS pancake coil electrode made by Bi-2223/Ag are studied. Breakdown in LN$_2$ is dominated electrode shape and distance. The relation between surface flashover voltage is considered for FRP. This research presented basis information of electrical insulation design for double pancake coil type HTS transformer.

  • PDF

Dielectric Insulation Properties of Double Pancake Coil Type HTS Transformer (Double Pancake Coil형 고온초전도 변압기의 전기적 절연 특성)

  • 백승명;정종만;이현수;한철수;김상현
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.2
    • /
    • pp.151-156
    • /
    • 2003
  • High temperature superconductor can only be applied against an engineering specofication that has to be determined for each particular application form the design requirements for economic viability and for operation margins in service. However, in order to realize the HTS transformer, it is necessary to establish the high voltage insulation technique in cryogenic temperature. Therefore, the composite insulation of double pancake coil type transformer are described and AC breakdown voltage characteristics of liquid nitrogen(LN$_2$) under HTS pancake coil electrode made by Bi-2223/Ag are studied. The Breakdown of LN$_2$ is dominated electrode shape and distance. The influence of pressure on breakdown voltage is discussed with th different electrode. For the electrical insulation design of turn-to-turn insulation for the HTS transformer, we tested breakdown strength of insulation sheet under varying pressure. And we investigated surface flashover properties of LN$_2$ and complex conition of cryogenic gaseous nitrogen(CGN$_2$) obove a LN$_2$ surface. The surface voltage of GFRP was measured as a function of thickness and electrode distance in LN$_2$ and complex condition of CGN$_2$ above a LN$_2$ surface. this research presented information of electrical insulation design for double pancake coil(DPC) type HTS transformer.

A Study on Insulation Degradation Phenomena in 22kV CV Power Cable (22kV CV케이블에 있어서 절연열화현상의 고찰)

  • Kang, Moo-Seong;Kim, Dong-Shik;Jung, Seong-Yong;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1797-1800
    • /
    • 1996
  • In this study, the insulation selected in degra-dated-power cable has been observed and aging process about the insulation has been investigated. Most Insulation aging process initiates in the interface of semiconducting layer and the type of the process is the fractal form that was observed between the the semiconducting layer and insulation layer. It is possible to estimate degree of the degration of cable with breakdown test and obtained data have been used to get parameters in order to use Weibull distribution. With this method it is considered to be possible to estimate situation of degration and life prediction.

  • PDF

Revitalization Methods of EIFS for High-rise Residential Buildings through Using TACT and Gangform System with Hanging Scaffolding

  • Lee, Sang-Hyun;Yi, June-Seong;Shin, Seung-Woo;Kang, Hae-Min
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.4
    • /
    • pp.407-418
    • /
    • 2011
  • Recently energy management measures at the political level, for the purpose of reducing energy consumption in the building sector, are being actively introduced. As a practical method, the exterior insulation method, which is proven to effective in reducing the energy loss through walls, has been favored. In this study, detailed implementations are suggested to activate exterior insulation system which can improve the housing insulation performance. The newly designed Gang-form system with hanging scaffolding was suggested to revamp constructability for finishing outer wall. The research results are based on a multifaceted analysis of the current problems of exterior insulation systems, and on recommendations proposed by exterior insulation experts in the Charrette discussion. The study has indicates that the customized TACT schedule considering the site condition has shortened the construction period to 5 months from 7.5 months. Through utilizing the suggestions of this study, the prevalence of exterior insulation systems is expected to become widespread.

Study on Long-term Performance of Phenolic Foam Insulation through Accelerated Aging Test (가속화 시험을 통한 페놀폼 단열재의 장기성능 비교분석에 관한 연구)

  • Kim, Jin-Hee;Kim, Sang-Myung;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.2
    • /
    • pp.11-23
    • /
    • 2020
  • The application of the high-performance insulation materials for buildings seems to be an essential measure for reducing energy use in buildings. Phenolic foam is a readily available insulation material with thermal conductivity of about 0.018 to 0.020 W/(mK). It has the advantage of higher thermal resistance and better fire resistance compared to other conventional building insulation materials. Insulation material used for building envelope is regarded as one of the decisive factors for building's energy load. Furthermore, the degradation of its thermal performance over time increasingly affects the building's energy use demand. Generally, the life span of conventionally built buildings is expected to be more than 50 years, so the long-term performance of insulation materials is critical. This paper aims to evaluate the long-term performance of phenolic form boards through an accelerated aging test. The tests were conducted according to BS EN 13166 and KS M ISO 11561. Based on the results of the accelerated aging test, the thermal performance variation of the material was analyzed, and then its aged value after 25 years was computed. Also, the characteristics of the phenolic foam board's long-term performance were also examined based on the standard testing methods adopted.

A Basic Study on Light-weight Concrete Using Wasted Form Polyurethane (폐발포 폴리우레탄이 혼입된 경량 콘크리트의 기초적 연구)

  • Park, Sang-Hyo;Lee, Seong-Gyu;Lee, Min-Hi
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.356-362
    • /
    • 2016
  • Light-weight concrete uses forming agents for reducing weight and high heat insulation property. However, the forming agents make problems of decreased volume and compressive strength of the concrete. This research aims to having weight-reduction and securing heat insulation property using recycled wasted form polyurethane without any forming agents. A small quantity of admixture used for constructability and avoiding material segregation. We picked admixtures from two different companies which shows evenly dispersed of wasted form polyurethane. This research conducts a study on the effect of mixing ratio of admixture on the light-weight concrete used wasted form polyurethane. As a result of the test, increased mixing ratio of the admixtures results reduced fluidity of concrete. On the other hand, percentage of moisture content and compressive strength are increased slightly. Combustibility performance and sound insulation performance are also secured, as well.

Modeling of Heat Transfer Equations for Estimation of Temperature Variations Inside the Oil Transport Pipe Line (원유 수송관 내부의 온도 변화 예측 을 위한 열전달 방정식의 모델링)

  • Jin, J.J.;Chung, H.T.;Bae, J.S.;Lee, S.O.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.300-303
    • /
    • 2008
  • In the present study, the simple form of the heat transfer equation were suggested to estimate the temperature variation inside the oil pipe in order to determine the thickness of the insulating materials to retain the working oils below the critical temperature. The conservation of the thermal energy at arbitrary time were modeled to one dimensional unsteady equation with the empirical formula or data. The calculating results for non-insulation case showed that the temperature were very sensitive to the thermal convection by the velocity of the external wind. For insulation case, the insulation material which has higher density and specific heat, lower thermal conductivity should be chosen with more brighter coloring outside the pipe in order to retain the working oils below the critical temperature.

  • PDF

Study on the Field Application of Insulation Performance Improvement Concrete (단열성능 향상 콘크리트의 현장 적용성 평가에 관한 연구)

  • Kang, Sung-Hyuk;Kim, Jung-Ho;Choo, Kyoung-Nam;Park, Young-Shin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.17-18
    • /
    • 2014
  • Recently, climate change have increased consumption of building heating and cooling energy. Therefore, various actions to reduce greenhouse gas and energy consumption have been prepared by world developed countries. The energy consumption by buildings approximately reaches 25% of total korea energy consumption. The greatest part in the buildings of the energy consumption is building facade. Especially the outer covering of the building has been made of concrete more than 70%. But a few research projects on concrete comprising more than 70% of outsider of buildings has been tried. This research is structural insulation concrete what improved insulation performance using Micro Form Admixture and Calcined Diatomite Powder and Lightweight Aggregate.

  • PDF