• Title/Summary/Keyword: Insulation Effect

Search Result 735, Processing Time 0.033 seconds

Studies on the Thermal Insulation Effect of Bedding (II) - Thermal Insulation Effect of Quilt - (이부자리의 보온력에 관한 연구(II) -이불의 보온력 -)

  • Lee Song-Ja;Sung Su-Kwang
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.16 no.4 s.44
    • /
    • pp.349-355
    • /
    • 1992
  • Comfortable sleeping largely depends on human mental state, physical condition, the temper. ature and humidity in bedrooms, and qualities of quilt and bedcover. Of the qualities of quilt, thermal insulation effect plays the most important role in keeping bedroom in ample temperature and preventing human body from giving off heat. In the present study, which is a sequel study to research on the thermal insulation effect, the real-size quilts with the following items of filling materials in them are designed to research on the variation of each item, and to measure the effect of the weight variation in inner covers on the thermal insulation effect of quilts, the results are as follows: 1. The coefficient between the weight of filling materials and the thermal insulation effect of quilt is shown to be a significant $0.91\~0.97$. 2. The thermal insulation effect of the quilts with in size of $0.5\;Kg/m^{2}$ is surveyed to be high in order down > polyester > cotton > wool. 3. The effect of the texture of inner covers on the thermal insulation effect of quilt is shown to be ignorably low. 4. The weight of filling materials is shown to be in correlation with the thermal insulation effect of quilts, and the estimated regression line has been obtained.

  • PDF

Multi-layered Effect for the Insulation Design of a HTS Cable (고온초전도 케이블의 절연설계를 위한 적층효과)

  • Kwag, Dong-Soon;Cheon, Hyeon-Gweon;Kim, Hae-Jong;Cho, Jeon-Wook;Chung, Soon-Yong;Kim, Sang-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.10
    • /
    • pp.950-955
    • /
    • 2005
  • For the insulation design of a high temperature superconducting(HTS) cable, three kinds of design method were proposed, which used AC and impulse withstand voltage and partial discharge inception strength. However, the designed insulation thickness by AC and impulse could not be applied to cable fabrication process due to much low electrical breakdown strength. The effect of the multi-layered insulation paper was not considered on the previous insulation design and the insulation thickness by partial discharge inception strength could be applied only. In this paper, the electrical breakdown characteristic, which considered the effect of multi-layered of LPP, was investigated to design the insulation thickness.

Studies on the Thermal Insulation Effect of Bedding(III) - Thermal Insulation Effect of Underquilt - (이부자리 보온력에 관한 연구(III) - 요의 보온력 -)

  • Lee, Song-Ja;Sung, Su-Kwang
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.17 no.2
    • /
    • pp.301-306
    • /
    • 1993
  • Since the underquilt has an important role of supporting the human body in sleeping, it needs to sustain ample degrees of hardness, elasticity, humidity absorption, and warmth retention property and also to have the two ergonimical requirements : It should not be too soft to allow human bodies to sink in, and that it should be comfortable for humans to tum over in sleeping. This study aims to investigate the effect of the thermal insulation of the variation in weight applied to the underquilt. For this purpose, six items were selected as filling materials for the underquilt : cotton, wool, silk, down, polyester, cotton/ployester. Various weights were applied to each of the underquilts to survey the reduction tendency of its thermal insulation effect. The results are as follow : 1. The Thermal insulation effect of each underquilt decreased in an exponetial function as the weight on the underquilt was increased. 2. The thermal reduction curves according to the load weight insrease were shown to be constant in shape regardless of the weight increase. 3. At the weight of more than $25kg/m^2$ the degree of the thermal insulation effect of each underquilt was found to be in order of down>cotton>silk>polyester>wool>cotton/ployester. 4. The variation in load weight applied to each underquilt was shown to be in reverse correlation with the thermal insulation effect. An estimated regression formula can be made on the data.

  • PDF

Parametric Study on the Heat Loss of the Reactor Vessel in the Nuclear Power Plant (원자력 발전 원자로 용기의 열손실 설계인자에 관한 연구)

  • Jong-Ho Park;Seoug-Beom Kim
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.5
    • /
    • pp.827-836
    • /
    • 2004
  • The design parameter of the heat loss for the pressurized water reactor has been studied. The heat loss from the reactor vessel through the air gap. insulation are analysed by using the computational fluid dynamics code, FLUENT. Parametric study has been performed on the air gap width between the reactor vessel wall and the inner surface of the insulation, and on the insulation thickness. Also evaluated is the performance degradation due to the chimney effect due to gaps left between the panels during the installation of the insulation system. From the analysis results, the optimal with of air gap and insulation thickness and the value of heat loss are obtained The results show how the heat loss varies with the air gap width and insulation thickness. The temperature and the velocity distributions are also presented. From the results of the evaluation. the optimal air gap width and the optimal insulation thickness are obtained. As the difference between the predicted heat loss and measured heat loss from the reactor vessel is construed Primarily as losses due to chimney effect. the contribution of the chimney effect to the total heat loss is quantitatively indicated.

A Study on Mechanical, Electrical Properties of Epoxy/MICA Composites with MICA Filled Contents (Epoxy/MICA 복합체의 MICA 충진함량 변화에 대한 기계적, 전기적 특성연구)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.2
    • /
    • pp.219-227
    • /
    • 2013
  • This paper reported a study on the thermal, mechanical and electrical insulation properties of epoxy/mica composites. To investigate the effect of mica content, glass transition temperature, mechanical properties such as tensile and flexural strength, and insulation breakdown properties for epoxy composites with various contents of mica. The effect of insulation thickness on insulation breakdown property was also studied. It was observed that tensile and flexural strength decreased with increasing mica content, while elastic modulus increased as the mica content increased. AC insulation breakdown strength for all epoxy/mica composites was higher than that of neat epoxy and that of the system with 20 wt% mica was 14.4% improved. As was expected, insulation breakdown strength at $30^{\circ}C$ was far higher than that at $130^{\circ}C$, and it was also found that insulation breakdown strength was inversely proportion to insulation thickness.

Analysis of the Energy Saving Effect for the External Insulation Construction by Building Load Calculation Method (건물 부하계산 프로그램을 이용한 외단열 시공의 에너지 절감 효과 분석)

  • Park, Jaejoong;Myeong, Jemin;Song, Doosam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.3
    • /
    • pp.97-104
    • /
    • 2017
  • Reinforcement of insulation in apartment buildings reduces the heating and cooling energy consumption by lowering the heat transfer in the building envelope. There are differences between internal and external insulation methods in heat transmission properties. However, some building load calculation programs cannot analysis the differences between the two. This is because these programs do no account for the timelag or thermal storage effect of the wall according to the location of insulation. In this study, the heat transmission characteristics of internal and external insulation were analyzed by EnergyPlus, and heating and cooling energy demand was compared. The results showed that external insulation system had lower heating and cooling loads than internal insulation system. Also the heat transfer rate of external insulation is steadier than internal insulation. About 13.6% of heating and cooling energy demand decreased when the outdoor wall was finished with external insulation compared to the demand with internal insulation.

An Analysis on Thermal Insulation Effect of Farm Structures Coated with Surface Treatment (표면코팅 구조재의 달열효과 분석)

  • Suh, Won-Myung;Yoon, Yong-Cheol
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.4
    • /
    • pp.39-46
    • /
    • 2004
  • This experiment was carried out to study on the effect of surface coating on thermal insulation of farm structures to improve thermal resistance and reflective effect of solar radiation. Nine different types of experimental specimen were compared in the temperature variations of inside and outside; A, B, C, D. E and F types are box container and G, H and I types are drum container. The size of these containers is $1,500{\times}2,000{\times}2,500$ mm and ${\varphi}$ $280{\times}330$ mm, respectively. Specimen of 3-type box(A, B, C) is galvanized steel sheet of thickness 0.45 mm. D, E and F types are sandwich panel of the thickness 50 mm inserted with urethane, glass wool and polystyrene form, respectively. G, H and I types are paint pot using in general. The surface of A. D, E, F and I types didn't any treatment, B, C and G types were treated with thermal insulation coating on the outside surface(B, G) or the inside and outside surface(C). And H type was treated with water paint coating on the only outside surface. In general, the experimental results showed the following tendencies; In case of A, B and C types. it was found that the thermal insulation effect of types coated with thermal insulation coating was improved remarkably than that of no treatment. And the thermal insulation effect between steel sheet and sandwich panel type was nearly similar There was not a significant difference of thermal insulation effect between thermal insulation coating and water paint coating. In time of drum container filled with rough rice, The difference of heat transfer tendency and temperature variation among surface treatments was nearly similar that of box types of galvanized steel sheet. And there was time lag about 6 hours between the temperature of middle part of rice and that of inside or outside surface.

Examination of insulation effect by simulation of Curtain wall insulation Warm block (커튼월 프레임 단열층의 시뮬레이션을 통한 단열효과 검토)

  • Hong, snag-hun;You, Nam-Gyu;Jung, Ui-In;Kim, Bong-Joo;Kang, Hui Tae
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.234-235
    • /
    • 2018
  • The development of insulation,the most important factor, is slow. The curtain wall market is getting bigger as the bulidings are getting bigger, but the insulation of the window is getting a problem. In order to solve this problem, we want to develop the insulation block used in the window frames. We will examine the insulation effect by using the existing Azon insulation block and the thermal worm convex which is to be developed with Therm 7.4 program.

  • PDF

A Study on Relationship Insulation Thickness and Infiltration Load by Window (단열재 두께 변화와 창호 침기 부하와의 관계)

  • Choi, Jeong-Min;Cho, Sung-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.5
    • /
    • pp.422-427
    • /
    • 2012
  • This study investigates on the relationship between total load which is caused by infiltration and insulation thickness against compensation effect. As the result of experiment, the PVC(Synthetic resins sash) window frame in airtightness is superior to the AL(Aluminum sash) window frame. In this study, as the increasing of insulation thickness in reference building does not reduce significantly cooling load, the compensation effect due to airtightness against infiltration is very small. But the compensation effect against infiltration can be closely related with heating load. Therefore, the proper thermal insulation thickness can be needed respect to cooling and heating load.

A study on the heat insulation performance of vapor penetration-insulate complex waterproofing system. (수증기 투과형 단열 복합 방수 시스템의 단열 성능에 관한 연구)

  • Choi, Su-Young;An, Ki-Won;Jang, Duk-Bae;Kim, Jong-Phil;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.62-63
    • /
    • 2016
  • In addition to the waterproof sheet waterproof objectives that apply to the building roof it is being constructed, including a complex such as insulation performance, root-resistance. However, thermal insulation of the composite waterproofing sheet is an insulating effect a wide variety depending on the specific construction -specific, material and even the effect is this part of the test to the generation when insignificant compared to each other a number of roof insulation effect of the insulation composite waterproof sheet that is currently in effect analysis.

  • PDF