The development of LVI tester for application of transformers winding deformation diagnosis (변압기 권선변형 진단에 적용하기 위한 LVI 시험기 개발)

  • 조국희;김광화
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.5
    • /
    • pp.97-103
    • /
    • 2002
  • The assessment of the condition of a transformer winding which is suspected of having suffered short circuit damage can be difficult. Conventional test such as winding resistance, magnetic current or insulation resistance will only detect damage if a permanent electrical fault exists. Visual inspection of windings necessitates the removal of oil and in many cases only a very small proportion of the winding can be seen. We describe the characteristic of LVI test system and methods to detect the deformation of windings in the power transformers. As the front rise time of recurrent-surge generator pulse less than 1000 ㎱ and the peak value of pulse is about 500 V, we have the good results of detecting winding deformation in the LVI test of transformers.

UHF Narrow Band Type Partial Discharge Diagnosis Method for the Internal Insulation Performance Verification of the Gas Insulated Switchgear (가스절연 개폐장치의 내부절연 성능검증을 위한 UHF 협대역 부분방전 진단법)

  • Song Won-Pyo;Kim Jung-Bae;Kim Min-So;Jung Jae-Ryong;Park Seung-Jae;Ko Heui-Suk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.9
    • /
    • pp.414-420
    • /
    • 2005
  • A method for partial discharge diagnosis based on UHF narrow band type for GIS has been developed and calibrated. In generally, PD cannot be directly measured under on-line condition, but we can indirectly measure the electromagnetic wave made by PD using the high-frequency antenna. Compared with VHF band, electromagnetic waves of UHF band have a low influence for external noise in high-voltage substation. Therefore, we can detect the real abnormality with several pC in GIS using UHF narrow-band type method. For the case of no internal VHF sensor for GIS of the domestic substation, it has applied to use the external UHF sensor attached in spacer in GIS of existing substation. In this paper, we firstly described the technique of partial discharge measurement using frequency analysis and phase analysis in UHF band. Secondly, we presented the results of sensitivity test, the relationship of dBm-pC and diagnosis result of the cause of PD source by phase analysis. And then, we report the diagnosis result of partial discharge on the real GIS in domestic substation. These results make above method applicable for measurement of quantity and cause of PD for real operation GIS in high-voltage substation.

Characteristics of Capacitive Coupler for Partial Discharge Measurement in 6.6kV Rotating Machines (6.6kV 회전기 부분방전 측정용 Capacitive Coupler 특성)

  • Kang, Dong-Sik;Yoon, Dae-Hee;Kim, Yong-Joo;Yun, Yung-Ho;Lee, Jung-Jun;Song, Sang-Ock
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1619-1622
    • /
    • 2001
  • Recently many researches on the diagnosis of stator winding insulation for large rotating machines have been developed sine the 1970s. Capacitive coupler has been the most widely used sensor for on-line partial discharge(PD) in rotating machines. The 105 [pF] ceramic coupler(CC) has been developed to continuously measure the PD activity in operating motor stator windings. This paper presents frequency characteristics and laboratory test to compare traditional 80 [pF] epoxy-mica coupler(EMC) and 105 [pF] CC for PD measurement in 6.6 [kV] stator windings.

  • PDF

Determination Method of O.T. Aging Level by Model Partial Discharge Test (모의 부분방전 시험에 의한 O.T. 절연열화 판정기준 설정 방안)

  • 진상범;권동진;곽회로;정용기;조국희
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1995.10a
    • /
    • pp.85-95
    • /
    • 1995
  • This paper describes a diagnosis of transformer by ultrasonic signal due to partial discharge. The ultrasonic signal can be measured when partial discharge is generated in a real transformer. The trend of partial discharge in transformer was estimated by counting the number of ultrasonic signals until insulation paper in the point-to-plane electrode is destroyed. The number of ultrasonic signals is closely related to the number of the electrical signals by partial discharge. The trend of the ultrasonic signal number could easily be distinguished by taking moving average.

  • PDF

The optical measurement and wavelet analysis about ultrasonic signals by discharge in oil (유중방전 초음파 신호의 광학적 측정 및 wavelet 분석)

  • Lee, S.H.;Lee, H.C.;Jee, S.W.;Kim, Ch.N.;Song, H.J.;Lee, K.S.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.298-303
    • /
    • 2004
  • It is well known that a discharge in oil is the source of various physical phenomena. Ultrasonic-wave detection is a useful method to the diagnosis of the transformer-insulation condition. Conventionally, ultrasonic waves are detected by Piezo-electric transducer, and we use optical method that has many advantages. In this paper, we constructed a Mach-Zehnder interferometer with optical fiber and investigated the principle of operation. Test arrangement is based rut the needle-plane electrode system in oil and applied AC high voltage Ultrasonic waves were detected and showed signal- analysis results with wavelet transform.

  • PDF

Development of Partial Discharge Measuring Sensor and System for Mold Transformer (몰드변압기용 부분방전 측정 센서 및 시스템 개발)

  • Kang, D.S.;Sun, J.H.;Cho, K.H.;Lee, S.M.;Yun, Y.H.;Lee, D.Z.;Oeu, S.Y.;Kim, J.H.;Choi, K.N.
    • Proceedings of the KIEE Conference
    • /
    • 2005.11c
    • /
    • pp.99-102
    • /
    • 2005
  • In order to development of diagnosis system for mold transformer, partial discharge measurement technique is recommended the best effective method for the evaluation of insulation condition on high voltage winding part. However, this technique was not applied to mold transformer yet. The purpose of this paper is to describe the method of partial discharge measurement for mold transformer with coupling sensor and measuring system. As we reviewed and developed the on-line partial discharge test technique, ceramic coupling sensor, measuring system, terminal box and index parameters.

  • PDF

Development of On-Line Partial Discharge Monitoring System in High Voltage Motors (고압전동기 운전중 부분방전 감시 시스템 개발)

  • Kim, Hee-Dong;Kong, Tae-Sik;Ju, Young-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1175-1178
    • /
    • 2004
  • On-line partial discharge(PD) monitoring system has been developed to monitor in operating large motor stator insulations. This system makes use of remote diagnosis techniques for the evaluation of PD activity in the control center of thermal power plant. This system can be remotely accessed via a modem to build database, analyze status and interpret the pattern of PD activity. A personnel computer is generally connected to ten motors to continuous measurement of the PD activity. The test data can be easily interpreted by a maintenance staff. For assessing the condition of stator winding in motors, this system ensures a reliable measurement and accurate estimation. Capacitive couplers used for on-line PD measurement have been 80pF. The maximum PD magnitude(Qmax), PD pattern and normalized quantity number(NQN) were performed by this system.

  • PDF

Reliability Assessment of High Voltage Rotating Machine Stator Windings Through Off-line Diagnosis (고압회전기기 고정자권선의 Off-line 진단을 통한 신뢰성 평가)

  • Chang, Jeong-Ho;Lim, Jae-Il;Lee, Dong-Keun;Lee, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1628-1629
    • /
    • 2011
  • 산업현장에서는 회전기기의 고체절연시스템(solid insulation system)의 열화정도를 평가하기 위하여 일정 진단주기에 맞춰 Off-line 상태에서 직류시험 및 교류시험을 통하여 효과적으로 절연물에 대한 상태평가를 시행하고 있다. 직류시험으로는 절연저항, 성극지수(PI) 시험 등이 있으며 교류시험으로는 교류전류시험(${\Delta}I$), 유전정접시험(${\Delta}tan{\delta}$), 부분방전(PD)시험이 있다. 여기서 부분방전은 절연체의 국부적인 열화현상을 추정할 수 있는 중요한 파라미터로, 부분방전시험(PD test)을 통하여 고정자권선(stator winding)에 대한 절연특성을 효과적으로 진단할 수 있다. 고압 전동기는 기동정지의 빈번함과 장기간 운전에 의해 열적, 전기적, 기계적 스트레스를 받게 되고, 이로 인해 과열, 진동, 절연파괴에 이르는 문제점이 발생되어 결국 시스템의 운전정지를 초래하는 심각한 사고로 이어질 수 있다. 따라서 고압 전동기의 절연상태를 주기적으로 감시하고 사고 징후를 검출하여 시스템을 안정적으로 운영하기 위한 고압 전동기 Off-line 절연진단에 대하여 기술하고 수차발전기에 대한 절연상태진단 결과를 바탕으로 절연시스템의 신뢰성 평가 방법에 대하여 고찰하고자 한다.

  • PDF

A Study on the Measurement of Ultrasound Velocity to Evaluate Degradation of Low Voltage Cables for Nuclear Power Plants (원전 저압케이블 열화도 평가를 위한 초음파 음속계측에 관한 연구)

  • Kim, Kyung-Cho;Kang, Suk-Chull;Goo, Charles;Kim, Jin-Ho;Park, Jae-Seok;Joo, Geum-Jong;Park, Chi-Seung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.325-330
    • /
    • 2004
  • Several kinds of low voltage cables have been used in nuclear power plants for the supply of electric power, supervision, and the propagation of control signals. These low voltage tables must be inspected for safe and stable operation of nuclear power plants. In particular, the degradation diagnosis to estimate the integrity of low voltage rabies has recently been emphasized according to the long use of nuclear power plants. In order to evaluate their degradation, the surrounding temperature, hardness of insulation material, elongation at breaking point (EAB), etc. have been used. However, the measurement of temperature or hardness is not useful because of the absence of quantitative criteria; the inspection of a sample requires turning off of the power plant power; and, the electrical inspection method is not sufficiently sensitive from the initial through the middle stage of degradation. In this research, based on the theory that the ultrasonic velocity changes with relation to the degradation of the material, we measured the ultrasonic velocity as low voltage cables were degraded. To this end, an ultrasonic degradation diagnosis device was developed and used to measure the ultrasonic velocity with the clothing on the cable, and it was confirmed that the ultrasonic velocity changes according to the degradation of low voltage cables. The low voltage cables used in nuclear power plants were degraded at an accelerated rate, and EAB was measured in a tensile test conducted after the measurement of ultrasonic velocity. With the increasing degradation degree, the ultrasonic velocity decreased, whose potential as a useful parameter for the quantitative degradation evaluation was thus confirmed.

A case of Asbestosis, Pleural Effusion and Lung Cancer Caused by Long-Term Occupational Asbestos Exposure (석면분진폭로에 의하여 석면폐증과 늑막삼출액 폐암이 합병된 1예)

  • Jung, Jang-Young;Ahn, Hyeong-Sook;Kim, Jee-Won;Kim, Kyung-Ah;Yun, Im-Goung;Kim, Han-Wook;Choi, Young-Mee;Song, Jeong-Sup
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.6
    • /
    • pp.651-657
    • /
    • 1994
  • Asbestos is widely used in the textile, asbestos cement, construction products, friction material, paper products, insulation products, chemical and plastic products because of its heat resistance, flexibility, tensile strength, and texturability. It is now generally recognized that longterm and excessive inhalation of asbestos dust causes asbestosis, lung cancer, malignant mesothelioma and malignancies in other organs such as cancer of gastrointestinal tract, leukemia, lymphoma. Although eighty thousand tons of asbestos has been annually consumed since 1979 in korea, it has not been reported asbestos and lung cancer by asbestos dust so far, while a case of mesothelioma was officially diagnosis as a occupational disease at 1993. We experienced firstly a case of asbestosis and lung cancer caused simultanously by occupational asbestos exposure 11 years, which was confirmed by chest x-ray, pulmonary function test, chest CT and HRCT, bronchoalveolar lavage, and gallium scan. And so We present a case of asbestosis, pleural effusion and lung cancer with a review literature.

  • PDF