• 제목/요약/키워드: Insulation Degradation

검색결과 230건 처리시간 0.03초

복합 감지 시스템을 이용한 부분방전의 절연열화 수명추정 (A Life Prediction of Insulation Degradation Using Complex Sensing System)

  • 김성홍;김재환;박재준;최재관;윤헌주;이영상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.348-350
    • /
    • 1997
  • Because of internal voids ininsulators give rise to partial discharge(PD), which cause local breakdown and even entire insulation breakdown. Treeing due to PD is one of the main causes of breakdown of the insulating materials and reduction of the insulation life. Therefore the necessity for establishing a method to diagnose the aging of insulation materials and to predict the breakdown of insulation has become important. From this viewpoint, our studies diagnose insulation degradation using the method of computer sensing system, which has the advantages of PD and acoustic emission(AE) sensing system. To use advantages of these two methods can be used effectively to search for treeing location and PD in some materials. In analysis method of degradation. We analyzed the PD pulse and AE pulses by regression analysis, compared to these obtained the correlation coefficient and determination coefficient by T-distribution and saw that PD and AE pulses show a similar pattern on the whole. Finally using statically operator such as the center of gravity(G), the gradient of the discharge distribution(C), we have analyzed for the prediction of life which we can be obtained the time, occurred of many pulse of small discharge amplitude.

  • PDF

폴리머 애자의 트래킹 열화 평가방법 연구 (Study of test method of tracking degradation for polymer insulation)

  • 심대섭;박병락;박성균;소진중
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.391-394
    • /
    • 2000
  • EPDM/silicone blend was prepared with polyorganosiloxane compatibilizer for out-door polymer insulation used to shed. Each blend had various weight ratios, 100/0, 90/10, 70/30, 50/50, 30/70, 10/90, and 0/100 as EPDM to silicone, and electrical and tracking characteristics were studied with the method of IEC 60587. And also, tracking properties and contact angle related to UV-weathering period were studied to understand the degree of degradation of blend after 1000 h UV-weathering.

  • PDF

고온초전도 변압기를 위한 액체질소 중 절연 파괴, V-t. 열화 특성 (Breakdown, V-t and Degradation Characteristics of Insulation in Liquid Nitrogen for HTS Transformer)

  • Nguyen, Van-Dung;Joung, Jong-Man;Baek, Seung-Myeong;Lee, Chang-Hwa;Suck, Song-Hee;Kim, Sang-Hyun
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권6호
    • /
    • pp.316-323
    • /
    • 2004
  • HTS transformer is one of the most promising devices to supply enough electric energy for quick increase consumption. However, for practical design of the HTS transformer, it is necessary to establish the research on breakdown, V-t characteristics, degradation, and so on. In this paper, we discussed breakdown characteristics and V-t characteristics of polyimide/L$N_2$ and glass fiber reinforced plastic/$LN_2$ composite insulations. These composite insulations have been used as turn-to-turn and layer-to-layer insulations for HTS transformer respectively, Moreover, we investigated the degradation of these insulation samples after breakdown using microscope and SEM photograph.

복합열화에 의한 형권 고정자권선의 절연신뢰성에 관한 연구 (A Study on the Insulation Reliablity of Form-Wound Stator Windings by Complex Degradation)

  • 이헌돈;김상걸;오현석;왕종배;김기준;이준웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.152-155
    • /
    • 2000
  • PWM inverter-fed traction motor is able to occur problems by additive transient surge stress and harmonic loss in contrast with motor driven by 60Hz sine wave alternating source. Therefore in this paper, test method and standard of existed already were investigate, "thermal + electric" complex degradation test that considered additive degradation occurred by inverter drive carried out in order to obtain insulation reliability of traction motor driven by inverter. It seems that this test method confers large value of application at reliability estimation which the subject of complete motor not windings sample from now on.

  • PDF

SF6 가스 절연변압기의 절연특성과 부분방전 (Insulation Characteristics and Partial Discharge for the SF6 Gas Insulated Transformer)

  • 선종호;김우성;김광화;오원근;하영식
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.740-747
    • /
    • 2000
  • This paper describes insulation characteristics and partial discharge for the SF6 gas insulated transformer. The characteristic of gas insulated transformer and the degradation sequence of solid insulation under SF6 gas atmosphere were explained. The model electrode system of the types that the aramid papers were inserted between two sphere electrodes was prepared. The partial discharge tests were carried out to that system and the insulation characteristics were considered.

  • PDF

전자부품의 새로운 절연평가기법 연구 (A Study on the New Evaluation Method on Insulation of Electronic Components)

  • 길경석;송재용;문승보;차명수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.503-504
    • /
    • 2006
  • This paper describes a low-level partial discharge(PD) testing that has been accepted as a non-destructive test method on insulation performance of electronic components. A comparative PD analysis combined with the Withstand Voltage Test (WVT) specified in IEC standards is carried out on high frequency switching transformers. The analysis shows that insulation degradation of the transformers under test progresses during the WVT. To avoid insulation degradation of the specimen, PD test has to be carried out at as low voltage as possible. In this study, the PD test on the transformers is performed in ranges from 50% to 70% of the test voltage specified in the WVT by measuring apparent charges below 1 pC. From the experimental results, it is expects that the low-level PD test is applicable for electronic components as a replacement of the WVT.

  • PDF

6.6 kV 케이블의 절연저항 측정을 위한 부하전류 및 온도 측정 (Load Current and Temperature Measurement for Measuring the Insulation Resistance of the 6.6 kV Cable)

  • 박용규;조영식;이관우;엄기홍;박대희
    • 한국전기전자재료학회논문지
    • /
    • 제28권1호
    • /
    • pp.46-50
    • /
    • 2015
  • The cable degradation process is largely divided into three steps; Step 1 : Thermal degradation, Step 2 : Weibull degradation, Step 3 : Partial discharge. it is progress in step order. This article aims to explain the process of cable degradation using the method of insulation resistance and accordingly to compose and manufacture a system of measuring the life of electrical cable. Before measuring the insulation resistance, a system of measuring the temperature and current of cables was made, and the established system was installed for test on the site of a power plant to collect the measured data. The current sensor was used TFC30P80A-CL420, and temperature sensor was used the DK-1270 PT100 sensor as RTD sensor. When measured the temperature and the load current at the same position, was confirmed that in case of the load current value was high, also temperature value high. Therefore, the correlation between load currents and temperature was verified, and the analysis of diagnostic data was evaluated, which could be utilized in identifying the fault condition of cable systems.

공동주택의 단열현황 조사 및 단열보강 적용방안에 관한 연구 ((A)Study on Apartment Insulation Status and Insulation reinforcement Application)

  • 정의인;김봉주
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.226-227
    • /
    • 2015
  • This research is to measure and analyze the thermal performance of the apartment structure and to evaluate and establish standards of thermal insulation defect in order to make the basic data necessary for determining the degree of the thermal performance degradation and for repairing and reinforcing the exterior wall of the existing apartment. The following conclusions could be derived thorough the investigation of outer wall temperature distribution and the insulation assesment experiments using a model of specimens for the apartment houses' outer walls. It was confirmed that for the thermal performance through the insulating material thicknesses 5cm, 8cm in walls, the thermal insulation thickened by 3cm, from 5cm to 8cm, but that the actual temperature difference reached only about 1 ~ 2℃. This implies that the thermal performance improvement using the thermal insulation in walls is not significant and that it is difficult to insulate the thermal bridge area.

  • PDF

고정자권선의 절연열화 특성분석 (Analysis of the Insulation aging for the stator winding)

  • 오봉근;최교남;한창동;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 전기설비
    • /
    • pp.23-24
    • /
    • 2006
  • Stator winding of hydro generator is gradually deteriorated by multi-stress and steady degradation of insulation results in insulation breakdown. The region where insulation breakdown occurs in stator winding is part where the multi-stress causes the defect of insulation material and electrical stress has been concentrated. Therefore, we judged locations of insulation breakdown to be varied according to various stress factors in service. In this paper, we drew the stator winding of hydro generators which has run for a long time and separated it into 3 parts(central part, end winding part, drawing part) according to the positions laid on the core. We performed electrical and thermal stress on these specimens for 1000 hrs under the same condition, measured the condition regularlyand analyzed the insulation status of each winding by performing partial discharge test. In addition, we analyzed the trend of partial discharge concerning specimens that caused the insulation breakdown during aging.

  • PDF

희귀분석을 이용한 복합 시스템의 열화진단 (Degradation Diagnosis of Complex System Using Regression Analysis)

  • 김성홍;송재주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 기술교육위원회 창립총회 및 학술대회 의료기기전시회
    • /
    • pp.60-66
    • /
    • 2001
  • 절연체 내부의 보이드로 인하여 부분방전이 발생하면 국부파괴와 완전절연파괴의 원인이 된다. 부분방전으로 생기는 트리잉은 절연재료를 열화 시키고 절연 수명을 단축시키는 중요한 원인이 되므로 절연파괴를 미연에 하여 절연재료 수명을 예측할 수 있는 방법에 대한 연구는 매우 중요하다. 이러한 관점에서 본 연구는 부분방전 및 음향방출 시스템을 이용한 컴퓨터 시스템을 개발하여 각 시스템의 장점을 이용함으로써 열화진단을 실시하였다. 부분방전 시스템의 장점은 음향에 비하여 검출 신호가 양호하고, 고전압 절연 장치의 신뢰성을 평가하기에 적합하다. 또한 음향방출 시스템의 장점은 전자기의 영향을 받지 않고, 열화 과정을 실시간으로 관찰할 수 있다는 것이다. 이 두 가지의 장점을 복합적으로 이용하면 절연재료 내부에서 발생하는 트리의 위치와 부분방전을 효과적으로 할 수 있다. 열화분석 방법으로 먼저 부분방전 펄스와 음향방출 펄스를 희귀분석하여 T검정에 의한 상관계수와 결정계수를 구하여 비교해본 결과 부분방전과 음향방출 펄스는 대체적으로 비슷한 형태를 보였다. 이것은 Yoshimura와 Fujita의 연구 결과와 일치하였다.

  • PDF