  • This study was carried out to investigate the effect of clothing habit on physiological adaptation to the change of season. The survey of clothing weight in fall '||'&'||' winter for 2 years, the frequency of cold infection in winter and degree of fatigue was performed with 110 female high school students. The actual condition of clothing and the correlations between clothing weight and cold infection, and between the clothing weight and degree of fatigue were suveyed. The results are followed as; 1. The clothing insulation was nearly same to indoor standard clothing insulation in H hun wearing normal clothing, but was higher 2 clo in S hun clothed uniform. Especially in spite of similar enviromental condition the clothing weight, minimum '||'&'||' maximum and variation of clothing weight for 2 years were showed to be heavier in S hun than H hun. Also indoor thermal sensation felt by the subjects indicated "cold", and the difference between clothing insulation and standard clothing insulation showed increase gradually. 2. L group was indicated to be lower in cold infaction ratio than M '||'&'||' H group, and the correlation between clothing group and cold infection ratio was recognized to be significant (p<0.05). And H hun and L-H group showed to be lower in cold infection ratio than S hun, H-L group. 3. The coefficience between clothing weight and degree of fatigue was recognized to be significant (p<0.05).

  • PDF

수력 발전기의 운전중 부분방전 측정기법에 대한 신뢰성 평가 (Evaluation of On-Line Partial Discharge Measurement Techniques on Hydro-Generator)

  • 황돈하;김진봉;김용주;박명수;김택수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1526-1529
    • /
    • 1994
  • In hydro-generator, a groundwall insulation of stator windings gradually deteriorates due to mechanical, thermal, electrical and environmental stresses. These stresses combine to result in loose windings, delamination of the stator insulation and/or electrical tracking of the end winding, all of which can lead to stator insulation failures. Conventionally, off-line tests such as partial discharge measurement, DC/AC current test and ${\Delta}tan{\delta}$ test has been used for estimation of winding condition. However, off-line test requires large power supply and generator outage. In addition, major cause of insulation problems such as loose wedges and slot discharges may not be found with off-line diagnoses. This paper describes the on-line partial discharge measurement techniques in the generator stator windings. The experimental results from the UIAM #1 hydro-generator confirms a optimistic application of on-line generator diagnosis method as a reliable tool for evaluation of winding condition.

  • PDF

고압전동기 고정자 권선의 절연상태 평가 (Assessment of Insulation Condition in High Voltage Motor Stator Windings)

  • 김희동;박의갑;박완조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2392-2395
    • /
    • 1999
  • This paper describes to access the insulation deterioration condition of the stator windings in six high voltage motors. Nondestructive tests have been carried out on stand-still motors. These tests include ac current increase rate($\Delta$I), delta tan delta(${\Delta}tan{\delta}$), and maximum partial discharge(PD). AC current and $tan{\delta}$ were measured by Schering bridge. The measurement of PD patterns were conducted using digital partial discharge detector. PD patterns were observed treeing and internal discharges in Motor 1 and 2. The stator windings of two motors were found to be in a poor condition and their were recommended to rewind. The stator. windings of four motors were judged to be in serviceable condition.

  • PDF

Revitalization Methods of EIFS for High-rise Residential Buildings through Using TACT and Gangform System with Hanging Scaffolding

  • Lee, Sang-Hyun;Yi, June-Seong;Shin, Seung-Woo;Kang, Hae-Min
    • 한국건축시공학회지
    • /
    • 제11권4호
    • /
    • pp.407-418
    • /
    • 2011
  • Recently energy management measures at the political level, for the purpose of reducing energy consumption in the building sector, are being actively introduced. As a practical method, the exterior insulation method, which is proven to effective in reducing the energy loss through walls, has been favored. In this study, detailed implementations are suggested to activate exterior insulation system which can improve the housing insulation performance. The newly designed Gang-form system with hanging scaffolding was suggested to revamp constructability for finishing outer wall. The research results are based on a multifaceted analysis of the current problems of exterior insulation systems, and on recommendations proposed by exterior insulation experts in the Charrette discussion. The study has indicates that the customized TACT schedule considering the site condition has shortened the construction period to 5 months from 7.5 months. Through utilizing the suggestions of this study, the prevalence of exterior insulation systems is expected to become widespread.

복합절연물내의 에폭시 두께에 따른 AC 절연파괴 분석 (AC Breakdown Analysis by Epoxy Thickness in Composite-Insulation)

  • 정해은;윤재훈;김병철;강성화;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.468-469
    • /
    • 2007
  • $SF_6$ gas used widely as insulating component in electric power industry has excellent in insulation and arc extinguishing performance in gas-insulated switchgear. However, the concern about eco-friendly alternative gas is currently rising, because $SF_6$ gas is one of the main greenhouse gases. As one of the study for $SF_6$ free technology, composite-insulation technology is focused in this paper. To analyze the influence by epoxy thickness change, the composite-insulation composed of dry-air and epoxy was used in this paper. To analyze AC breakdown by the epoxy thickness, needle-plane electrode was used and needle was molded by epoxy. Under the gas pressure ranged from 0.1 to 0.6MPa, the breakdown voltage of dry-air were measured in AC electric field. The data of composite-insulation were acquired by changing the thickness of epoxy used in each composite-insulation under the same condition.

  • PDF

새만금 간척지 첨단온실 에너지 설계를 위한 풍환경 및 온실 피복재의 영향 분석 (Analysis on Insulation of Wind Environment and Greenhouse Cover Materials Insulation for Advanced Greenhouse Energy Design in Saemangeum Reclaimed Land)

  • 서효재;서일환;노득하;이학성
    • 생물환경조절학회지
    • /
    • 제32권1호
    • /
    • pp.57-63
    • /
    • 2023
  • 본 연구에서는 새만금과 같은 간척지를 활용하여 대규모 첨단온실단지를 조성하는 경우 간척지의 환경적 특수성 중 높은 풍속에 따른 유리 단열재의 에너지 효율을 평가하였다. 현장에서 주로 사용되는 온실 단열재 중 4가지에 대한 평가 결과, 최대 37.4%의 에너지 차이를 보여, 온실 피복재의 선정이 중요함을 제시하였다. 이를 바탕으로 일반적인 내륙에서의 온실을 설계하는 것과 달리, 간척지에서는 내재해성 온실규격을 따라 시설을 설계하여야 하며, 에너지 소비량은 높아진 풍속과 재질을 고려하여 산정되어야 한다. 본 연구의 결과는 에너지 효율성을 온실 피복재의 종류와 풍속에 따라서 제시하고 있으며, 이는 대규모 첨단온실 조성 시 에너지 소비량을 예측하고, 이를 바탕으로 신재생에너지원을 포함하는 에너지 설계에 활용될 수 있다

GT-96 멤브레인형 LNGC의 급냉기간에서의 열해석 (Thermal Analysis for the GT-96 Membrane Type LNGC during the Cool-down Period)

  • 이정혜;최현규;최순호;오철;김명환;김경근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1346-1351
    • /
    • 2004
  • This study is concerned with the thermal analysis during the cool-down period of 135,000 $m^3$ class GT-96 membrane type LNG carrier under IMO design condition. The cool-down is performed to cool the insulation wall and the natural gas in cargo tank for six hours to avoid the thermal shock at the start of loading of $-163^{\circ}C$ LNG. During the cool-down period, the spraying rate for the NG cooling decreases as the temperature of NG falls clown from $-40^{\circ}C$ to $-130^{\circ}C$ and the spraying rate for the insulation wall cooling increases as the temperature gradient of the insulation wall is large. It was confirmed that there existed the largest temperature decrease at the 1 st barrier and 1st insulation, which are among the insulation wall, especially in the top side of the insulation wall. By the 3-D numerical calculation about the cargo tank and the cofferdam during the cool-down period, the temperature variation in hulls and insulations is precisely predicted.

  • PDF

수력발전기 고정자 노후권선의 모의결함 시편에 대한 부분방전 파라미터 변화 분석 (Analysis of Parameters on Partial Discharges from Insulation Defects of used Hydro Generator Stator Windings)

  • 오봉근;김현일;강성화;임기조
    • 한국전기전자재료학회논문지
    • /
    • 제20권7호
    • /
    • pp.645-649
    • /
    • 2007
  • Partial discharge(PD) test for simulated insulation defects of used hydro generator stator winding was conducted to analyze the PD Parameters. Simulated insulation defects are classified by 5 types corona, slot, internal, multi and aging defect. Phase resolved partial discharge, statistical parameter (skewness, kurtosis), PD magnitude as a function of the test voltage(Q-V curve) and PD magnitude change under test voltage for 2 minutes are used as PD parameters. The analysis of PD parameters by 4 types are proved to be useful methods. In particular, PD parameter characteristics of aging defect could help to assess the aging condition of stator winding because aging defect has more weak insulation strength than other insulation defects : PD distribution is wide and flat, PD rises rapidly near $0^{\circ}\;and\;180^{\circ}$ and Q-V curve rises sharply and then gently drops.

UHF 및 가스센서를 이용한 SF6 가스 상태 감시기술 기초연구 (Fundamental Study on the Maintenance Technology for SF6 Gas Condition using Pressure and UHF Sensors)

  • 안희성;조성철;엄주홍
    • 조명전기설비학회논문지
    • /
    • 제21권2호
    • /
    • pp.20-27
    • /
    • 2007
  • 정보화 시대로 변화함에 따라 고품질 전력의 중요성이 강조되고 있으며 이를 보장하기 위한 전력기기 운전의 신뢰성 향상이 선결과제로 대두되었다. 특히 대용량 전력기기 중 개폐기와 차단기의 성능을 일정 수준 이상으로 유지하기 위한 예방진단기술이 발달되어 왔다. 개폐기와 차단기에서 많이 사용되는 $SF_6$ 가스의 절연성능을 검출하여 유지보수 여부를 결정하는 것이 매우 중요하다. 본 연구에서는 이러한 $SF_6$ 가스의 절연성능을 검출하기 위해 사용되는 여러 가지 방법 중에 전기방전에 의해 나타나는 여러 현상을 검출하는 센서들의 기초특성을 확인하고 파악된 특성을 통해 복수의 검출센서를 사용할 것을 제안하였다. 즉 코로나 방전이나 아크방전 시에도 사용할 수 있는 UHF 센서와 방전전류 검출기를 병용하는 것이 $SF_6$ 가스의 절연성능 확인에 유리할 것으로 판단되었다. 이외에도 가스센서를 이용한 $SF_6$ 가스의 절연상태 검출을 시도해 그 가능성을 시험해 보았다.

가스터빈 발전기 회전자 권선의 절연상태 평가 (Assessment of Rotor Winding Insulation Condition for Gas Turbine Generators)

  • 김희동;김병래
    • 전기학회논문지
    • /
    • 제57권10호
    • /
    • pp.1818-1821
    • /
    • 2008
  • Several off-line diagnostic tests which include the insulation resistance(IR), polarization index(PI), low-voltage AC, and recurrent surge oscillograph(RSO) tests were performed to assess the condition of generator rotor windings. The low-voltage AC and the RSO tests were performed on the gas turbine generator rotor winding to detect shorted turns. Before intentionally applying artificial shorted faults, it was confirmed by the low voltage AC and the RSO tests that the winding was in sound condition. For simulated shorted rotor winding turns, the RSO test detected the fault in the winding. The RSO test was capable of identifying the number and pole location of the shorted turns for a number of simulated shorted coils.