• Title/Summary/Keyword: Insulating paper

Search Result 490, Processing Time 0.026 seconds

The Aging Diagnosis of OF Cable Insulation Oil by Characteristic Change (OF 케이블 절연유의 특성 변화에 따른 경년열화진단)

  • 윤구섭;정우성;김철운;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.35-40
    • /
    • 1997
  • As demand of electric power are growing and transmission line limited owing to enlargement of the downtown area The eonfidence of underground transmission cable which shows gradual growth are high. It is found whether insulating ability is good or not. In this paper, The exper iment result is shown that the fall of insulating ability and take preventive measure through the analysis of tans, water content, dielectric breakdown voltage, total acid number, volume resistivity , and gas in the oil in an accordance with the characteristic change of oil used very much for insulating oil of cable.

  • PDF

The Effect of Filter in the Static Charge Elimination Methodes for Streaming-Electrification Insulating Oil. (유동대전된 절연유의 제전방식중 필터에 의한 영향)

  • 정광현;김용운;신재화;김보열;이덕출
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.11a
    • /
    • pp.361-364
    • /
    • 1995
  • The static charges are generated by streaming electrification phenomena when insulating oil flowing by force for the purpose of cooling at the internal of Ultra-high power transformer. In this thesis, their elimination method was studied. The falter represents a greet much electrification characteristics because falter has large interfaces with liquid. In this paper, the streaming-electrification phenomena of insulating oil by metal filter were measured by mesh number, oil flow rate, oil temperature and a kind of mesh and The effect of charge elimination by metal filter generated minus ion was measured.

  • PDF

Investigation of Arc Breaking Characteristic for Arc Chamber in Molded Case Circuit Breakerg (배선용차단기의 소호구조에 의한 한류 특성 연구)

  • Kim, Yong-Gi;Song, Jung-Chun;Ryu, Man-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.708-710
    • /
    • 2001
  • In this paper, back commutation phenomena for iron chute chamber in AC low testing. For this experimental we used high speed camera and carried out with same prospective currents up to 10kA RMS. Hybrid arc quenching chambers which are composed with iron plate and insulating materials tested for reducing back commutation phenomena in interrupting process. It is shows that hybrid chambers which are various narrow slot path width reduces back commutation. As a result, a new type arc quenching chamber is to force the arc rapidly into a narrow insulating slot with iron plate. By this means the arc is lengthened and squeezed between insulating walls. Using this model, the behavior of the arc squeezed in the hybrid chamber and characteristics of arc voltage are also investigated.

  • PDF

Dielectric and Breakdown Characteristics of Interfaces in XLPE Cable Accessories (XLPE 케이블 접속함에 있어서 이종계면의 절연 및 유전특성)

  • HwangBo, S.;Jeon, S.I.;Lee, K.C.;Oh, E.J.;Park, D.H.;Han, M.K.
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.216-218
    • /
    • 1993
  • XLPE cable accessories are mainly consisted by the combination of various insulating materials such as XLPE cable insulation, rubber, epoxy, etc. It is important to investigate the dielectric and breakdown characteristics of the interfaces between various insulating materials. In this paper, by testing and measuring the breakdown strength, dissipation factor, volume and surface resistance and conduction current of specimens, we report the dielectric and breakdown characteristics of interfaces between various insulating materials.

  • PDF

A Study on Suggestion of Insulating Oil Ageing Degree in Pole-Transformer by Absorbance (흡광도법에 의한 주상변압기 절연유의 열화판정기준 설정에 관한 연구)

  • Lee, Dong-Zoon;Jung, Jong-Uk;Kim, Kyung-Hwa;Kwak, Hee-Ro;Yun, Yong-Ja
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1851-1853
    • /
    • 1996
  • In this paper the criteria for insulating oil condition of pole transformer were suggested by applying the UV-Visible spectrophotometric method. Ageing of insulating oil caused the change in absorbances of oil os well os the deterioration of electrical properties of oil. By comparing the electrical properties such as $tan{\delta}$ and breakdown voltage with the UV-Visible absorbances of oil, criteria for absorbance values determining oil condition were established. This UV-Visible spectrophotometric method might be applied in ageing analysis of oil and be expected to replace the current method.

  • PDF

Analysis on the Diagnosis Characteristics of Electrical Insulating Oil for Power Transformer with 3-terminal Capacitive Sensor (3전극형 전기용량 센서를 이용한 변압기 절연유의 열화감지특성 평가)

  • Kim, Ju-Han;Seo, Pan-Seok;Kim, Pil-Hwan;Kim, Myung-Hwan;Park, Hung-Seok;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2004.11d
    • /
    • pp.89-92
    • /
    • 2004
  • This paper described the capacitive sensor for the diagnosis of deterioration of electrical insulating oils applying guard-ring type the 3-terminal electrodes. To measure stable capacitance of the sensor and to determine the design factors of the sensor, we utilized computational analysis, FEM software. This capacitive sensor discern the extent of deterioration measuring relative permittivity of electrical insulating oils. The result of measuring numerous sample, mineral oils, as serviced year, we confirmed an increase in relative permittivity of oils. Moreover, we confirmed the superior characteristics of the sensor as a species, aged pattern of oils and operating temperature.

  • PDF

The Measurement of Partial Discharge to Diagnose Defects in High-Voltage Insulating Materials (고전압 절연재료의 결함진단을 위한 부분방전측정)

  • 이정빈;정우성;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1994.11a
    • /
    • pp.134-138
    • /
    • 1994
  • According to request of insulating materials for high-voltage, recently we make effort not only to develop diagnostic skills of aging state but also to discover defects in insulating material in the early. Especially, partial discharge has been actively studied as a non-destructive diagnosis technique and very useful method. Because the method of partial discharge measurement has damages less than other conventional diagnosis technique. In this paper, the characteristics of partial discharge was investigated and studied on many samples with voids. In order to adapt as a practical diagnosis technique, it is studied on the characteristics of partial discharge and insulation breakdown in the high voltage. We suggest that partial discharge measurement can be used in order to diagnose defects in high-voltage insulation materials.

A Study on the Radiation Induced Current of X-ray Insulating Oil (X선 장치용 절연유의 방사선 유기전류에 관한 연구)

  • 김영일;정연택;이덕출
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.7
    • /
    • pp.549-556
    • /
    • 1989
  • Radiation induced current of the insulating oil used for X-ray tube housing was investigated in this paper. The X-ray induced current increased in proportion to the X-ray intensity and X-ray wave length and was greatly affected by the temperature of the insulating oil and the gap length` however, the current was not varied by the amount of the X-ray absorbed. The results suggest that one must consider the following problems as important factors for X-ray machine design and normal operation: cooling system of the X-ray tube housing, X-ray intensity, increasing temperature due to continuous operation, years used, and oil exchange and management.

  • PDF

The Effect of Contaminants on Tracking Aging in Polymer Insulating Materials (고분자 절연재료의 트랙킹 열화에 미치는 오손액의 영향)

  • 조한구;박용관
    • Electrical & Electronic Materials
    • /
    • v.10 no.8
    • /
    • pp.770-777
    • /
    • 1997
  • Some polymer materials including epoxy resin are being instead of porcelain for outdoor insulating materials such as insulators bushings cable terminators and surge arrester housing. And the largest problem to be overcomed is the tracking and erosion of the outdoor polymer material brought about by dry band arcing during prolonged exposure to contaminations. In this paper the effect of surface tension wettability flow rate of contaminants with varying surfactant content and frequency of applied voltage on the tracking breakdown of epoxy insulating materials were investigated. As the flow rate of contaminant is increased the surface resistivity is decreased and the leakage current is increased the time to tracking breakdown is decreased. It is found that time to tracking breakdown depends on the surface tension of contaminant that is difference of wettability. And as the frequency of applied voltage is increased time to tracking breakdown decreased.

  • PDF

The influence of filler for silicone rubber tracking (실리콘 고무의 트래킹에 미치는 충전재의 영향)

  • 허창수;장기순;조한구
    • Electrical & Electronic Materials
    • /
    • v.9 no.4
    • /
    • pp.344-350
    • /
    • 1996
  • Tracking is one of the biggist problems to be overcome in polymeric materials for outdoor insulators. But It can be decreased with the addition of filler such as alumina trihydrate (ATH). In this paper, the tracking of surface and evaluation of insulating ability at silicone rubber is investigated, using the salt fog test. At initial state, the peak leakage current and numbers by dry band arcing is increasing with increasing the filler level, but at aged state decreasing at high concentration filler samples. This is because the roughness of the surface may contribute to the increase in peak leakage cur-rent and numbers. As increasing the filler level, the insulating ability of materials is higher and weight loss is decreased. The mechanism of insulating failure is occurred by the erosion than the tracking and the erosion caused weight loss of 2 g.

  • PDF