Technology of Electrical Barrier Material (전기차단성 소재 기술)

  • Shin, Eun-Mi
    • Elastomers and Composites
    • /
    • v.46 no.1
    • /
    • pp.22-28
    • /
    • 2011
  • Various materials are used as electrical barrier materials, such as glass, insulating oil, gas, paper and polymer. These materials shut off electricity from conductor as a barrier and separate as well as support conductor from outside environment while using electrical equipment. Polymers are generally used for cable insulation material. Recently environmental regulation are reinforced and eco-friendly materials are in trend.

Electric Field Distribution Simulation of the Cable Joint Materials (케이블 접속재료의 전계분포 시뮬레이션)

  • 김형주;변두균;신종열;이덕진;이충호;홍진웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.601-604
    • /
    • 2001
  • The insulation materials of cables used for underground power transmission requires a higher insulating capability, and the most popular method to examine the cable is partial discharge test due to applying variation voltage. In the thesis, air void, silicone oil, of which may possibly exist real cables, are simulated by Electro 2D program. Also the relations between calculated field strength and the void defect type in the cable joint materials. In the modeling, eclectic field inner to the cable joint material composed by XLPE and EPDM is modeling simulated. We obtained the electric field distribution in void due to two conditions.

  • PDF

A study on the streaming electrification phenomena of the insulating oil flowing through the nozzle (세관을 통과하는 절연유의 유동대전에 관한 연구)

  • 이덕출;박재윤
    • Electrical & Electronic Materials
    • /
    • v.3 no.4
    • /
    • pp.332-338
    • /
    • 1990
  • 본 연구는 절연유가 금속 파이프 중을 통과할 때 흐르는 유동전류 특성에 대하여 실험적으로 규명하였다. 유동전류는 파이프 길이, 절연유의 속도 및 온도에 따라 변하는 것이 관측되는데 파이프 길이가 4-6cm부근에서 피이크치가 나타나고 유속의 증가에 따라서는 선형적으로 증가하며 그리고 유의 온도가 약 50.deg.C 부근에서 또한 피이크가 나타나고 있다. 절연유에 전하를 주입시키는 수단으로 코로나 방전을 이용하였으며 부코로나 대전된 절연유의 유동전류가 코로나 대전 시키지 않은 절연유나 정코로나 대전된 절연유의 것보다 큰 값이 관측되었다. 이 결과로부터 고체 액체 접촉시 액체중의 음이온이 화학 포텐셜에 의하여 고체 표면에 흡착된다는 사실과 유동전류의 방향 및 발생기구를 해석할 수 있다.

  • PDF

Chemical and Mechanical Characteristics on the Insulating Material in Mineral Oil by Thermally Accelerated Aging Test (가속 열열화 시험에 의한 광유 함침 절연물의 화학적, 기계적인 특성)

  • Kang, Seok-Young;Han, Sang-Ok;Kim, Ju-Han;Lee, Byung-Seong;Park, Hyun-Ju
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1496-1497
    • /
    • 2006
  • 본 논문은 가속 열열화 시험에 의한 광유 함침 절연물의 기계적 특성과 화학적 특성을 비교하였다. 가속 열열화 시험에 사용된 절연물은 셀룰로오스 절연지와 광유를 사용하였고, 가속 열열화 시험 방법은 ANSI/IEEE C57.91-1982에 의해 $150^{\circ}C $로 1000시간을 열화하였다. 가속 열열화 시험에 의해 절연재료의 주성분인 셀룰로오스 절연지는 열화로 인해 글루코시딕 결합체가 깨진다. 이때 생성된 셀룰로오스 절연지의 클루코오스 분해 생성물 분석을 위해 평균 중합도법을 사용하였고, 기계적인 특성은 인장강도법을 수행 하였다.

  • PDF

Effect of Amino Silane Coupling Agent on the AC Electrical Breakdown Phenomena of Epoxy/Layered Silicate Nanocomposite in Needle-plate Electrodes

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.3
    • /
    • pp.149-152
    • /
    • 2012
  • The effects of amino silane coupling agent on the AC electrical treeing and breakdown behaviors in an epoxy/layered silicate (1 wt%) were examined in needle-plate electrode geometry. A layered silicate was exfoliated in an epoxy base resin by using our AC electric field apparatus. To measure the tree initiation and propagation and the breakdown rate, an alternating current (AC) of 10 kV (60 Hz) was applied to the specimen in needle-plate electrode arrangement with a $30^{\circ}C$ insulating oil bath. In the epoxy/amino silane system, the tree initiation time was 11.5 times higher and the breakdown time was 17.9 times higher than those of the neat epoxy resin. The tree initiation time in the epoxy/layered silicate (1 wt%) system with the amino silane was 2.0 times higher, and the breakdown time was 1.5 times higher than those of the epoxy/layered silicate (1 wt%) system.

Accelerated life test of SF_6 gas load break switch for overhead line (가공용 가스절연부하개폐기 가속수명시험)

  • Park Seung Jae;Heo Jong Chul;Kim Maeng Hyun;Koh Heui Seog
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.551-553
    • /
    • 2004
  • SF_6 gas has been increasingly used as the insulating and arc-suppressing medium in switchgears which are used as the protection devices of power system. Nowadays, with these trends, SF_6 load break switches have rapidly substituted for the air or oil-type load break switches, in order to get higher reliability. And, the national standard was made for reliability assessment of SF_6 gas load break switch and testing facilities was also set in KERI(Korea Electrotechnology Research Institute ). This paper introduces the synopsis for the reliability assessment requirements specified in the standard and the assessment results.

  • PDF

The Effect of Fillers on Rubber Characteristics for Gasket to Lithium Ion Battery (리튬이온 전지용 가스켓 고무의 특성에 미치는 충전제의 영향)

  • Seo, Kwan-Ho;Cho, Kwang-Soo;Yun, In-Sub;Choi, Woo-Hyuk;Hur, Byung-Ki;Kang, Dong-Gug
    • Polymer(Korea)
    • /
    • v.34 no.5
    • /
    • pp.430-433
    • /
    • 2010
  • The gasket materials of for the lithium ion battery requires chemical resistance to electrolyte, electrical insulating, compression set, anti-contamination and low temperature property. To check the special characteristics of fillers which are applied to rubber for gasket, compound of EPDM, NBR and FKM (fluoro elastomer) were made by adjusting weights of carbon black and silica additive. Using these compounds, we had done tests of long-term stability against electrolyte, compression set and low-temperature property with considering operating condition of the lithium ion battery. From this test, we investigated the physical and chemical characteristics of rubber with using of carbon black and silica additive in each.

Development of HVDC 500kV PPLP MI cable systems in Korea (HVDC 500kV PPLP MI 케이블시스템 개발)

  • Lee, Soo-bong;Cho, Dong-sik;Lee, Tae-ho;Kim, Sung-yun;Lee, Su-kil;Jeon, Seung-ik
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1202-1203
    • /
    • 2015
  • This paper describes the development of HVDC ${\pm}500kV$ polypropylene laminated paper (PPLP) mass-impregnated (MI) type cable system for HVDC transmission lines. As you know, mass-impregnated type cable generally has only insulating layer with the Kraft paper impregnated with a high-viscosity insulating compound. But polypropylene laminated paper is made of a layer of extruded polypropylene (PP) film sandwiched between two layers of Kraft paper. Thanks to PP film and its combination with Kraft paper, PPLP has higher AC, Impulse (Imp.) and DC breakdown (BD) strengths as well as lower dielectric loss than conventional Kraft paper insulation. In addition, Kraft MI cable has a limitation for the maximum conductor temperature as $55^{\circ}C$ But this PPLP MI cable has higher maximum conductor temperature than that of Kraft MI cable due to advantage of oil drainage characteristics. It is the most economic type of cable for HVDC transmission. Also HVDC ${\pm}500kV$ PPLP MI cable system was developed including land joints and outdoor-terminations. In order to prove the mechanical and electrical performances, the type test was carried out according to CIGRE recommendations. A full scale cable system has been tested successfully. And additional load cycle and polarity reversal tests on the cable system showed a higher performance compared with a similar mass impregnated paper cable.

  • PDF

Defect Diagnosis of Cable Insulating Materials by Partial Discharge Statistical Analysis

  • Shin, Jong-Yeol;Park, Hee-Doo;Lee, Jong-Yong;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.11 no.1
    • /
    • pp.42-47
    • /
    • 2010
  • Polymer insulating materials such as cross linked polyethylene (XLPE) are employed in electric cables used for extra high voltage. These materials can degrade due to chemical, mechanical and electric stress, possibly caused by voids, the presence of extrinsic materials and protrusions. Therefore, this study measured discharge patterns, discharge phase angle, quantity and occurrence frequency as well as changes in XLPE under different temperatures and applied voltages. To quantitatively analyze the irregular partial discharge patterns measured, the discharge patterns were examined using a statistical program. A three layer sample was fabricated, wherein the upper and lower layers were composed of non-void XLPE, while the middle layer was composed of an air void and copper particles. After heating to room temperature and $50^{\circ}C$ and $80^{\circ}C$ in silicone oil, partial discharge characteristics were studied by increasing the voltage from the inception voltage to the breakdown voltage. Partial discharge statistical analysis showed that when the K-means clustering was carried out at 9 kV to determine the void discharge characteristics, the amount discharged at low temperatures was small but when the temperature was increased to $80^{\circ}C$, the discharge amount increased to be 5.7 times more than that at room temperature because electric charge injection became easier. An analysis of the kurtosis and the skewness confirmed that positive and negative polarity had counterclockwise and clockwise clustering distribution, respectively. When 5 kV was applied to copper particles, the K-means was conducted as the temperature changed from $50^{\circ}C$ to $80^{\circ}C$. The amount of charge at a positive polarity increased 20.3% and the amount of charge at a negative polarity increased 54.9%. The clustering distribution of a positive polarity and negative polarity showed a straight line in the kurtosis and skewness analyses.

Characteristics of hazardous oil & liquid fuel waste discharged from various industries (폐유 및 액상연료 공정 폐기물에서 무기물질류의 함량특성)

  • Shin, Sun-Kyoung;Jeong, Seong-Kyeong;Kim, Woo-Il;Jeon, Tae-Wan;Kang, Young-Yeul;Yeon, Jin-Mo;Cho, Yoon-A;Kim, Min-Sun
    • Analytical Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.276-286
    • /
    • 2013
  • This study was performed to investigate the contents characteristics of hazardous oil wastes and wastes of liquid fuels from different industrial process. In order to establish a hazardous waste list, samples of various industrial discharge have been analyzed for 16 non-regulated inorganic hazardous substances (i.e., Cu, Pb, Cd, CN, Hg, As, T-Cr, $Cr^{6+}$, Sb, Ni, F, V, Ba, Zn, Be, Se). In more detail, hazardous waste samples including waste hydraulic oils, waste engine, gear and lubricating oils, waste insulating and heat transmission oils, bilge oils, oil/water separator contents processing were collected from 37 workplaces and analyzed. We observed that the most of the inorganic substances exceeded the proposed criteria in many samples. Especially the concentration of Sb in heat transmission oil, bilge oil and gear & lubricating oils were ranged from 6 to 419 mg/kg whereas the proposed criteria is 50 mg/kg. The assessment result of hazardous waste in Korea according to the EWC showed that the out of 24 processes, 16 belongs to absolute entry and 8 belongs to mirror entry. In conclusion, we expect the outcome of this study to align the classification system of hazardous waste management in South Korea with international legislations, and consequently contribute to reduce environmental pollution as well as health risks by toxic wastes.