A study on conduction current and D.C. breakdown characteristics in dielectric liquids (절연유의 도전전류와 직류절연파괴특성에 관한 연구)

  • 서국철
    • 전기의세계
    • /
    • v.30 no.4
    • /
    • pp.231-236
    • /
    • 1981
  • It has been known that D.C. breakdown Voltage is lower than A.C. breakdown Voltage in insulatingoil, but there are still many unvivid points at electric conduction in breakdown or under of high electric field. This study measured the electric current-electric field characteristics (I-E characteristics) and the breakdown Voltage under of D.C. electric field of insulating oil using the system of electrodes that are near the Uniform electric field with a result. I can study, electric conduction in area of high electric field depends upon the Schottky effect. The liquidity of breakdown electric field takes place by the local concentration of electric field. The longer gap is and the more electric current is the more breakdown Voltage decreased. There are not almost the change of electric current-electric field characteristics by materials of electrode.

  • PDF

Development of 154kV Gas Insulated Transformer (154kV급 가스절연 변압기 개발)

  • Woo J.H.;Choi Y.L.;Kim K.M.;Lee J.Y.;Seok B.Y.
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.12
    • /
    • pp.532-539
    • /
    • 2005
  • The demand of Gas Insulated Transformer(GIT) using $SF_6$ gas as insulating and cooling medium is being increased dramatically in the underground substation of urban area because it has the advantages of non-flammable and non-explosive, etc. This paper describes the structural features and advantages of the gas insulated transformer compare to an oil immersed transformer, and presents a brief overview of the consideration and technology which apply to $SF_6$ gas insulated transformer.

Radiation Effect on Electrical Conduction of Insulating oil (절연유의 전기전도 현상에 미치는 방사선 영향)

  • 김영일;이덕출;정연택
    • Electrical & Electronic Materials
    • /
    • v.1 no.3
    • /
    • pp.235-242
    • /
    • 1988
  • 본 논문에서는 X선장치용 절연유의 X선 조사에 의한 전기전도 현상을 이해하기 위해서 X선량(1.2*$10^{4}$R), 인가시간, 분위기(공기, N$_{2}$가스, 진공), 전계 등의 특성과 전극 재료와 갭길이 의존성을 시료의 온도 30-100.deg.C 범위에서 도전전류를 측정하였다. 도전전류는 X선 미조사 절연유 보다는 저온 및 저전계 영역의 조사된 절연유에서 증가되었으나 고온과 고전계 영역에서는 구별되지 않았다. 이들 결과는 저온 및 저전계에서는 X선 조사에 의한 해리 및 이온화 작용에 의해 하전항체가 증가되고 있음을 생각할 수 있으며 X선장치 설계 및 취급 관리에 있어 적당한 자료로 제시할 수가 있겠다.

  • PDF

The Effect on the Streaming Electrification of Insulating Oils with Impurity (변압기유의 불순물에 따른 유동대전 영향)

  • 이용우;이광석;송병기;김왕곤;홍진웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.329-333
    • /
    • 1996
  • In this Paper, the streaming electrification of transformer oils generated at the interface of transformer oils and the AC breakdown with impurity is studied. The electrification current is measured by the electrometer connected the faraday cage. And a oil velocity is maintained equally. In case of the AC breakdown test, the temperature are 30[$^{\circ}C$], 50[$^{\circ}C$], 80[$^{\circ}C$] and 90[$^{\circ}C$], repetitively. As a result of breakdown experiment, the dielectric breakdown strength is decreased in low temperature region and is increased in high temperature region according to increase of contained sodium. In case of streaming electrification experiment, the streaming current is more increased with the specimen contained sodium than the original specimen.

  • PDF

The Effect of Interface Activation Substances in Reduction Phenomena of Streaming electrification (유동대전 감소현상에 미치는 계면활성제의 효과)

  • Kim, Y.W.;Lee, S.H.;Han, J.S.;Lee, E.H.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2146-2148
    • /
    • 1999
  • The purpose of this study is to find the way to reduce the electrostatics by interface activation substances added in the insulating oil with concentration[ppm]. As results. The streaming current, surface tension and viscosity of the samples added nonionic and hermaphrodic substances are decreased but the conductivity is increased at higher point than the 1[ppm] (c.m.c.), the other side the same phenomena of the samples added cationic and anionic substances are discovered at the 10[ppm].

  • PDF

Analysis of ultrasonic signals through media in transformer (변압기의 전달 매질에 따른 초음파 신호의 특성 분석)

  • Chin, Sang-Bum;Park, Hyun-Soo;Shin, Dong-Seok;Kwak, Hee-Ro;Kweon, Dong-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2057-2059
    • /
    • 1999
  • This paper describes the phenomena of the refraction and reflection when the ultrasonic signals generated by PD(Partial Discharge) in a transformer propagate through the boundary between insulating oil and the tank of the transformer. In this paper, considering the characteristic of the ultrasonic signal and the velocity of the propagation in medium, propagation time from PD source to sensor for incidence angle was calculated. As a result, it was found that the shortest time at specific angle exists. Taking into account the velocity of the propagation in medium, the shortest time with a computer was simulated. It was shown that the simulation was same as experimental result at a real PD source in the transformer.

  • PDF

The Effect of Antistatic Agent for Streaming Electrification on the Breakdown Characteristics of Synthetic Fluids (합성절연유의 절연파괴 특성에 미치는 유동대전 억제제의 영향)

  • Song, Byung-Gi;Lee, Soo-Won;Shin, Jong-Yeol;Shin, Hyun-Teak;Hong, Jin-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1414-1416
    • /
    • 1997
  • The electrical breakdown characteristics of the synthetic fluids No.2 of KS class VII used for insulating and cooling the materials for the ignition coil are studied. Also, Benzotriazole(BTA) as the streaming electrification suppressant additive is added to the oil, and the change of electrical properties due to different BTA concentration is investigated. To investigate the electrical characteristics, the breakdown strength of each specimen by an experiment for AC breakdown are analyzed. The breakdown strength of specimen by adding BTA is higher than virgin specimen in low e region, but lower than that in high region because of melting BTA. It is considered that the effective content of BTA as charge suppressant additive is about 10[ppm] from the results of AC breakdown.

  • PDF

A INSULATING DESIGN OF $SF_6$ GAS SEALING END OF CONDENSER CONE TYPE USED FOR 345KV OF CABLE (콘덴서 콘 방식의 345KV OF 케이블용 $SF_6$ 가스중 종단접속함의 절연 설계)

  • Kim, H.J.;Lee, S.C.;Oh, O.J.;Lee, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1553-1555
    • /
    • 1994
  • In this paper, we describes the research in condenser cone of $SF_6$ gas sealing end for 345KV oil-filled cable. The designed of condenser cone based on the results electric field analysis by electrostatics theory ana FEM. As a results. we have been designed the condenser cone and the inner insulation part of $SF_6$ seating end, the width and length, the number of condenser, the length of stress relief slope, the total length of condenser cone.

  • PDF

The Characteristics of RVM by Accelerated Aging in Insulating Materials of the Transformer (경년 열화에 따른 변압기 절연물의 회복전압 특성)

  • Kang, Seok-Young;Han, Sang-Ok;Kim, Jae-Hoon;Kim, Ju-Han;Lee, Sei-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07e
    • /
    • pp.73-75
    • /
    • 2005
  • In present measurement of moisture contents is used as one of method for estimating degradation of transformer. Most of people use Karl-Fischer titration method for detection moisture contents but this measurement is inconvenient method because we must analyze transformer oil-paper after dismounting transformer and sampling in field. Therefore we don't directly investigate them in field. In this paper we will introduce Recovery Voltage Method(RVM) that is new method for estimating measurement in field though dismounting facility. For measure of moisture contents using RVM in accordance with accelerated thermal aging we have made experimental test cell and aged at a temperature up to 140$^{\circ}C$ for 300 hours. And we have been measured at intervals of 100 hours using RVM 5462 made in fetter company.

  • PDF

Reliability for SF6 gas load break switch of distribution system (배전선로용 가스절연부하개폐기의 신뢰성 향상책)

  • Park, Seung-Jae;Heo, Jong-Chul;Shin, Young-June;Kang, Young-Sik;Koh, Heui-Seog
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.452-454
    • /
    • 2003
  • $SF_6$ gas has been increasingly used as the insulating and arc-suppressing medium in switchgears which are used as the protection devices of power system. Nowadays, most of power companies adopted the $SF_6$ gas-type load break switch for increasing the reliability of distribution network by its superior durability against external environmental condition, in substitution for air-type and oil-type switches. But, it is important to establish the general estimation process for the testing and estimation for long-term reliability. Accordingly, this paper presents the reliability testing method for $SF_6$ gas load break switch which is based on the analysis of the failure mode and the statistics.

  • PDF