Abstract

The demand of Gas Insulated Transformer(GIT) using $SF_6$ gas as insulating and cooling medium is being increased dramatically in the underground substation of urban area because it has the advantages of non-flammable and non-explosive, etc. This paper describes the structural features and advantages of the gas insulated transformer compare to an oil immersed transformer, and presents a brief overview of the consideration and technology which apply to $SF_6$ gas insulated transformer.

Keywords

References

  1. 한전표준변압기 사양서 참고목록
  2. '不燃性難練性變壓器の現 狀とその動向' 日本電氣學會技術報告 第459?, 1993
  3. 宮城克?,佐野貴弘 'ガス絶?變壓器捲線タ?ン間〈ぴギプ放 電におけゐモデル解析',明電時報,通?273?, No.4,2000
  4. 井上 保,寺西 常治,池田 正巳, 'Dielectric Characteristics of Turn-to-turn Insulation of Gas-Insulated Transformer for Various Impulse Voltage Application' 日本電氣學會誌 論文誌B, 120卷, 4號, pp. 569-575, 2000
  5. Y. Togawa, M. Ikeda, K. Toda and K. Esumi, 'Progress of Gas-insulated Transformer', IEEE Proceedings of International Conference of Energy Management and Power Delivery, pp. 540-547, 1995 https://doi.org/10.1109/EMPD.1995.500785
  6. Miller, D. S, 'Internal Flow Systems, 2nd Edition', BHRA(Information Services),1999
  7. Idelchik. I. E., 1994, 'Handbook of Hydraulic Resistance, 3rd Edition', CRC Press
  8. Kays,W. M., London, A. L., 'Compact Heat Exchangers, 3rd Edition', McGraw-Hill Book Company, 1999
  9. Robert M. Del Vecchio, Bertrand Poulin, Pierre T. Feghali, Dilipkumar M. Shah and Rajendra Ahuja., 'Transformer Design Principles,' Gordon and Breach Science Publishers, 1999