A Study on Adsorption Characteristics of Benzene over Activated Carbons Coated with Insulating Materials and Desorption by Microwave Irradiation (절연물질이 코팅된 활성탄의 벤젠 흡착특성 및 마이크로파에 의한 탈착에 관한 연구)

  • Kim, Ki-Joong;Ahn, Ho-Geun
    • Applied Chemistry for Engineering
    • /
    • v.19 no.4
    • /
    • pp.445-451
    • /
    • 2008
  • In order to regenerate the activated carbon polluted by volatile organic compounds (VOCs) using microwave, adsorption and desorption characteristics of benzene over activated carbon (AC) coated with insulating materials were investigated. Physical characteristics of activated carbon and insulator-coated ACs were investigated by means of $N_2$ gas adsorption and scanning electron microscopy (SEM). The amount of VOC adsorbed showed a positive relationship with the specific surface area of the ACs, and spark discharge over insulator-coated ACs did not occur. Potassium silicate (PS) was the best binder for coating of insulating materials on AC. Amount of benzene desorbed by microwave irradiation was dependent on output power of microwave. Nearly same performance was obtained even though the adsorption-desorption operation under microwave irradiation was repeated 5 times. Finally, it was known that the microwave heating was a very effective mean for regenerating the polluted AC.

Insulation Characteristics and Thermography Diagnosis of Porcelain Insulators for the Distribution Systems (배전용 자기재 현수애자의 절연특성과 열화상 진단)

  • Joung, Jong-Man;Kim, Dong-Myeong;Choi, Myung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.4
    • /
    • pp.267-271
    • /
    • 2011
  • The insulating characteristics and temperature rise behaviors of porcelain suspension insulators were investigated. The testing insulators had used in the distribution systems normally and were sampled. Firstly, leakage current was measured and its impedance was calculated. The leakage current of good insulators is 0.2 mA and its impedance is 66 $M{\Omega}$. The worse insulators have lower impedance and the insulators having below 15 $M{\Omega}$ take place flashover at the high frequency voltage flashover test. Secondly, the temperature rise characteristics were analyzed depending on leakage current and its impedance. Surface temperature of insulators was measured for 30 minutes and until its saturation after voltage was applied. The temperature rise of insulators having 15 $M{\Omega}$ is about $14.5^{\circ}C$ above the ambient temperature. Lastly, the heating behaviors of 3 insulators in a string was analyzed. Any insulator in the string does not generate heat so far as it has at least one sound insulator. On the other hand, all the insulators in the string are bad if the string have any heating insulator.

Reliability of N/O($SiO_2$/$Si_3$$N_4$) Films According to Top Oxidation Condition (상부산화 조건에 따른 N/O($SiO_2$/$Si_3$$N_4$) 구조막의 신뢰성 평가)

  • 구경완;홍봉식
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.9
    • /
    • pp.20-28
    • /
    • 1992
  • Dielectric thin film of N/O ($Si_{3]N_{4}/SiO_{2}$) for high density stacked dynamic-RAM cell was formed by LPCVD and oxidation(dry & pyrogenic oxidation methods) of the top 7nm $Si_{3]N_{4}$ film. The thickness, structure and composition of this film were measured by ellipsometer, high resolution TEM, AES and SIMS. The insulating characteristics(I-V characteristics) were investigated by HP 4145, and the characteristics of TDDB (Time Dependent Dielectric Breakdown) were evaluated by using CCST(Current Constant Stress Time) method. In this experiment, The optimum oxidation condition for preparation of good insulating and TDDB characteristics of N/O film was pyrogenic oxidation at 85$0^{\circ}C$ for 30 minutes. The leakage current was reduced from 400pA to 7.5pA when SiO$_{2}$ film with thickness of 2nm was formed on the top of $Si_{3]N_{4}$ film by the pyrogenic oxidation method.

  • PDF

A Study on the Diagnosis of Power Transformers by Analysis of Insulating Oil (절연유의 분석에 의한 변압기 진단에 관한 연구)

  • Kim, Kyeongsook;Lim, Chunsik;Park, Hyunjoo;Lee, Taewon;Yang, Seungran
    • Analytical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.166-172
    • /
    • 2000
  • The life expectation of power transformers is basically dependent on the aging deterioration of insulating paper which can not be obtained from operating transformers. Therefore, it will be very useful if we can manage transformers by indirect analysis of degradation products. "Furan derivatives" are known the decomposition products which are generated by the degradation of cellulose in insulating paper. We proved that 2-furfural is the only measurable product from our transformers, and determined easily the concentration of 2-furfural by HPLC without any specific pretreatments, Compared to concentration of $CO_2$ and CO by GC, the concentration of 2-furfural by HPLC can estimate more accurately aging characteristics of transformers. We expect that these results can be utilized to predict the aging characteristics and life diagnosis of power transformers.

  • PDF

New Uninterruptible Power Supply Using the Converter which is Secondary Auxiliary Soft Switching High Frequency Insulating PWM AC/DC (2차측 보조 소프트 스위칭 고주파 절연형 PWM AC/DC 컨버터를 이용한 새로운 무정전전원장치)

  • Suh, Ki-Young;Mun, Sang-Pil;Kim, Ju-Yong;Lee, Hyun-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.16-21
    • /
    • 2005
  • In paper, propose new partial resonance ZCS PWM controlled High frequency insulating Full-bridge DC/DC converter not using exciting current of high frequency transformer. It is compared with the existing principles in characteristics. It also realizes a widely stabilized ZVS operating using new ON-OFF control method at synchronized power rectification MOSFET of high frequency insulating transformer secondary. Besides, it is brought over 97[%] measurement efficiency by proposed DC-DC converts. It is proved effectiveness of new methods using DC UPS PWM rectifier as switching power supply.

Analysis on the Temperature Distribution Characteristics of Insulating oil of Transformer Using the Vegetable oil and Mineral oil (식물성 절연유와 광유가 사용된 유입변압기의 온도분포 특성)

  • An, Jung-Sik;Shim, Meoung-Seop;Jung, Joong-Il;Kim, Nam-Ryul;Huh, Chang-Su
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1215_1216
    • /
    • 2009
  • Most transformer use insulating and cooling fluids derived from petroleum crude oil, but mineral oil is some possibility of environmental pollution and fire with explosion. vegetable oil fluids extracted from seed has superior biodegradation and fire-resistant properties including an exceptionally high fire point enhancing fire safety. In this study, it is aimed at the practicality of substituting natural ester dielectric fluid for mineral oil in liquid insulation system of transformers. As a rise in coil winding temperature has a direct influence on transformer life time, it is important to evaluate the temperature rise of coil winding in vegetable oil in comparison with mineral oil. Three transformers for the test are designed with 10KVA, 13.2KV, one phase unit. The temperature are directly measured in insulating oil of these transformers with the two sorts of natural ester and mineral oil dielectric fluid respectively. Temperature of vegetable oil transformers was similar to temperature of mineral oil transformer in the same design at 80% load and above.

  • PDF

The Experimental Study on Seismic Capacity of 154 kV & 345 kV Main Transformer Bushings (154 kV 및 345 kV 주변압기 부싱의 내진성능 시험 연구)

  • Hwang, Kyeong Min;Ham, Kyung Won;Kim, Gyeong Hwan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.2
    • /
    • pp.87-94
    • /
    • 2018
  • In this study, seismic performance of bushings and their connection parts was analyzed by performing shaking table tests for various types of bushings widely used as auxiliary equipment of main transformers in domestic substations. As a result of the seismic tests of five types of 154 kV bushings according to the manufacturers, all the bushings secured the structural integrity even at the acceleration of 1.4 g and it was found that leakage of insulating oil didn't occur. Also, the average acceleration amplification rate at the upper part of the bushings was about 2.5 to 3.0 times higher than the lower one. On the other hand, when a representative 345 kV bushing was subjected to the seismic test, the structural integrity was secured even at 1.0 g acceleration similar to the design earthquake load level, but in this test, leakage of insulating oil occurred. However, when a stiffener restricting the connection of the bushing is installed in the same 345 kV bushing, the displacement of the bushing connection is controlled and the stiffener prevent the oil from leaking even at the acceleration of the designed seismic level.

The electrical conduction characteristics of the multi-dielectric silicon layer (실리콘 다층절연막의 전기전도 특성)

  • 정윤해;한원열;박영걸
    • Electrical & Electronic Materials
    • /
    • v.7 no.2
    • /
    • pp.145-151
    • /
    • 1994
  • The multi-dielectric layer SiOz/Si3N4/SiO2(ONO) is used to scale down the memory device. In this paper, the change of composition in ONO layer due to the process condition and the conduction mechanism are observed. The composition of the oxide film grown through the oxidation of nitride film is analyzed using auger electron spectroscopy(AES). AES results show that oxygen concentration increases at the interface between oxide and nitride layers as the thickness -of the top oxide layer increases. Results of I-V measurement show that the insulating properties improve as the thickness of the top oxide layer increases. But when the thickness of the nitride layer decreases below 63.angs, insulating peoperties of film 28.angs. of top oxide and film 35.angs. turn over showing that insulating property of film 28.angs. of top oxide is better than that of film 35.angs. of top oxide. This phenomenon of turn over is thought as the result of generation of surface state due to oxygen flow into nitride during oxidation process. As the thickness of the top oxide and nitride increases, the electrical breakdown field increases, but when the thickness of top oxide reaches 35.angs, the same phenomenon of turn over occurs. Optimum film thickness for scaled multi-layer dielectric of memory device SONOS is estimated to be 63.angs. of nitride layer and 28.angs. of top oxide layer. In this case, maximum electrical breakdown field and leakage current are 18.5[MV/cm] and $8{\times}{10^-12}$[A], respectively.

  • PDF

An Analysis of Tree Growth in the XLPE Interface (가교폴리에틸렌 계면에서의 트리성장 분석)

  • Kim, Cheol-Woon;Park, Hyun-Bin;Kim, Tae-Sung;Lee, Joon-Ung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.2
    • /
    • pp.90-94
    • /
    • 1998
  • This study aims at analyzing to treeing in the solid-solid interface which is insulation type of cable junction parts, the proceeding of tree-growth and electrical breakdown were research in the study. Interface was made artificially to detect how it influenced the insulating ability of the whole system, the specimen were XLPE generally used in cable. The interface conditions were divided into two parts. First condition being the one focused on the surface of interface, it was treated with sand paper (#80, #600, #1200). For the second condition, the pressure of interface was varied as the value of 1, 5, 10 [$kg/cm^2$]. Using above conditions, treeing and breakdown properties on tree-growth were respectively compared in details. As a result, breakdown time was shorter for the full range of supplied voltage in the case of interface existed in the joint than non-existed interface. In the case of existed interface, the interface which had high-interface pressure and painted with silicon insulating oil was the best in the aspect of breakdown characteristics.

  • PDF

Surface Characteristics and Tracking Resistance of Epoxy Insulating Materials against Ultraviolet (자외선 열화에 의한 에폭시 절연재료의 표면특성과 내트래킹성)

  • Cho, Han-Goo;Yoo, Dae-Hoon;Kang, Hyung-Kyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.495-496
    • /
    • 2008
  • This paper describes the influence of Ultra-violet irradiation on time to tracking resistance of epoxy insulating materials by use of the inclined plane test. And, the influence of surface degradation was evaluated through several method such as measurement of contact angle, surface roughness, using a scanning electron microscopy. As the 1000 hours of the surface degradation with UV-CON, the flashover time decreases at different rates depending on epoxy resin and silicone rubber specimen. As the duration of the surface degradation with UV-CON is prolonged, the contact angle of epoxy resin decreases at the rate of degradation time, while that of silicone rubber was not exchanged. It is assumed that this phenomenon is related to the decrease in hydrophobicity of the surface of the materials. Also, as to epoxy resin, the decrease of hydrophobicity due to surface degradation with UV-CON is greater than that resulting from surface degradation with WOM. The UV radiation produced chalking and crazing on the surface of the insulating materials specimen.