• 제목/요약/키워드: Insulating Form

검색결과 107건 처리시간 0.023초

내한제 및 단열거푸집을 이용한 한중콘크리트의 구조체 적용 실험 (An Experiment on the Structure Application of Cold Weather Concreting Using Anti-freeze Agent and Insulating Form)

  • 김경민;손성운;김기철;오선교;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2002년도 학술논문발표회
    • /
    • pp.21-26
    • /
    • 2002
  • This paper is intended to verify the efficiency of anti-freeze agent and insulating form by analyzing the temperature history and the property of strength-increase about the concrete that is placed in the insulating form and normal form, using new type anti-freeze agent in batcher plant According to the results about the temperature history, while the lowest temperature shows 3$^{\circ}C$ in case of normal concrete + euroform, 4$^{\circ}C$ in case of normal concrete + insulating form, it shows 6$^{\circ}C$ in anti-freeze agent + the insulating form, so the effect is most favorable. The compressive strength with mixing anti-freeze agent or not, shows high in order of standard curing, structure-managing and open air-placed specimen and the concrete mixing anti-freeze agent shows the highest compressive strength-increase.

  • PDF

Mock-up 부재에 적용한 단열 갱폼의 콘크리트 강도 특성 (Concrete Strength Characteristic of the Insulating Gang Form for Mock-Up Members)

  • 김지훈;남경용;임남기;정상진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.67-68
    • /
    • 2013
  • In this paper, the compressive strength of an insulating gang form member, which was developed to improve the cold weather concreting quality, and a general gang form member was measured by age to examine the compressive strength characteristics of the two members compared with the standard curing test piece.

  • PDF

내한제 및 단열거푸집을 이용한 한중콘크리트의 모의구조체 적용에 관한 실험 연구 (An Experimental Study on the Mock-up Test of Cold Weather Concreting Using Anti-freeze Agent and Insulating Form)

  • 김경민;손성운;김기철;오선교;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.663-668
    • /
    • 2002
  • In this paper, insulating effects and strength development of concrete placed at mock up model structure are discussed using anti freezing agent and insulating forms. According to test results, concrete containing 8% of anti freezing agent shows lower freezing temperature, earlier setting time and higher strength development than plain concrete. As for the temperature history of mock up structures, when plain concrete is placed at euro form, the temperature drops to -4${\circ}$ before early 24 hours, and when concrete containing anti freeze agent at euro form, it to -3${\circ}$ before early 24 hours. Nevertheless, when concrete containing anti freeze agent is placed at insulating form, it does not go below zero, and the concrete containing anti freeze agent enhances higher strength development.

  • PDF

단열재 조합에 의한 한중콘크리트용 거푸집 개발 (Development of Forms for Cold Weather Concrete by Combination of Insulation)

  • 한천구;오선교;신동안;김경민
    • 콘크리트학회논문집
    • /
    • 제15권3호
    • /
    • pp.392-399
    • /
    • 2003
  • 본 연구는 한중콘크리트 시공 시 초기보온 대책 중 가장 손쉽고 경제적일 것으로 사료되는 단열 보온양생을 대상으로 하였다. 실험은 한중콘크리트 시공조건을 상정하여 기존 거푸집과 각종 단열재 조합에 따른 단열거푸집간의 온도이력을 검토하여 효율적인 단열거푸집을 개발하고자 하였다. 실험결과 $-10^{\circ}C$ 일정인 외기온도 조건에서 벽용 거푸집의 경우, 일반 유로폼인 경우는 초기 24시간 이전에 급속한 온도저하에 의해 $0^{\circ}C$ 이하로 약 7시간 정도 지속되었고, PP+스티로폼+합판인 경우는 영상의 온도를 유지하고, 강도발현도 우수하며, 단열거푸집간 비교적 가격도 저렴하여 우수한 단열거푸집임이 밝혀졌다. 슬래브용 거푸집 실험의 경우, 하부는 단열거푸집으로 고정하고, 콘크리트 표면 양생방법을 달리하였을 때, 콘크리트의 온도이력을 측정한 결과, 노출시킨 경우 약 10시간 이후부터 영하로 저하하였고, 비닐+양생포의 경우 약 42시간 이후부터 영하로 저하하였다. 반면, 비닐+스티로폼+양생포를 사용한 양생의 경우에는 약 55시간 이후부터 영하로 저하하여 노출이나 일반적으로 많이 사용되는 비닐+양생포와 비교하여 우수한 단열효과임이 밝혀졌다. 7일 및 28일에 있어 슬래브의 코어 압축강도를 측정한 결과는 단열재를 사용하였을 때 크게 나타났다.

폴리우레탄 폼을 도포한 갱폼사용에 따른 콘크리트 온도이력특성 (A study on thermal properties of concrete using gang form coated with polyurethane)

  • 남경용;원준연;강인선;전판근;이영도;정상진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 춘계 학술논문 발표대회 1부
    • /
    • pp.11-12
    • /
    • 2011
  • This study examine Effect of Change of Compressive Strength of Concrete Members with Insulating Gang form on Temperature History of Concrete Positions. Test show, insulating gang forms differences and gang forms have 10℃ on peak point temperature of surface and Center if temperature history have 24Mpa by change of compressive strength. In addition, there have 14℃(16℃) on peak point temperature of surface and Center if temperature history have 40(60)Mpa. Therefore, insulating gang forms have an effect insulating performance.

  • PDF

친환경 식물성절연유의 유동대전현상 연구 (Research of Flow Electrification Phenomena of the used Environment-Friendly Vegetable Insulating Oils)

  • 최순호;허창수
    • 전기학회논문지
    • /
    • 제61권4호
    • /
    • pp.580-584
    • /
    • 2012
  • The insulating oils perform a cooling and insulation action in electric power transformer. The mineral oil has immanent fire dangerousness and environmental contamination problem. Vegetable insulating oil has higher ignition point, flash point and more excellent biodegradability than conventional mineral oil. In a real oil-filled transformers, some of the power is dissipated in the form of heat. And transformer require the heat to be removed from the winding and insulator by forced convection of the insulating oil. The flow electrification occurs when insulating oil was forced to be circulated. In this paper, influence of temperature, velocity of flow, and insulating pipe and diameter on streaming electrification of vegetable insulating oil was investigated using forced circulation apparatus. Temperature effects were most significant, and it showed a peak in the temperature $30^{\circ}C$ to $35^{\circ}C$ at insulating and copper pipe. The change of flow electrification according to area variety could be checked by change of diameter.

내한제 및 단열거푸집에 의한 한중콘크리트 시공의 효율화에 관한 기초적 연구 (A Fundamental Study on the Effectiveness of Cold Weather Concreting Using Anti-freeze Agent and Insulating Form)

  • 김경민;원철;김기철;오선교;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.617-622
    • /
    • 2001
  • This paper presents the effectiveness of cold weather concreting by applying both anti-freeze agent and insulating forms developed through previous study investigating insulating effects on the concrete and the strength gain. According to test results, in $-10^{\circ}C$ of air temperature, when euroforms are applied, the temperature of plain concrete drops below $0^{\circ}C$ and maintains its temperature during early 24 hours. However, when insulating forms are applied, the temperature of concrete keeps 8~$13^{\circ}C$ during first 24 hours. Insulating forms has better performance on insulating effects than existing euroforms. Concrete containing anti-freeze agent shows temperature rising effects about $1^{\circ}C$ compared to plain concrete. Strength gain of core concrete shows higher when insulating forms is applied.

  • PDF

오염된 누전차단기 절연재료의 트래킹 특성에 관한 연구 (A study on the Tracking Characteristics of Contaminated Insulating Materials of RCD)

  • 이춘하;옥경재;김시국;지승욱
    • 한국화재소방학회논문지
    • /
    • 제22권5호
    • /
    • pp.67-71
    • /
    • 2008
  • 본 논문은 국내에서 사용되고 있는 누전차단기 외함 절연재료의 오염에 의한 트래킹 특성을 연구하였다. IEC (International Electrotechnical Commission) 60589의 방법으로 만들어진 0.1 wt% NaCl 용액을 이용하여 KSC IEC 60112의 고체절연재료의 내트래킹 및 비교트래킹지수 측정 방법을 응용하여 실험을 하였다. 실험에 사용된 시료는 3개 제조사의 누전차단기를 사용하였으며, 누전차단기의 절연재료가 오염되었을 때 탄화도전로 발생시간 및 트래킹 발생형태를 분석하였다. 연구결과, 제조사별로 탄화도전로의 발생 시간 및 트래킹 발생형태가 상이하게 나타났다. 오염된 차단기의 절연재료의 트래킹 발생 시간이 정상시료보다 빠르게 나타났다.

저온환경하에서 단열처리 방법에 따른 단열거푸집의 열적성능에 관한 실험적 연구 (A Experimental Study on Thermal Performance of Insulated Forms with Different Insulating Methods at Low Temperature)

  • 김목규;김형철;최현국;김재영;문영범;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.57-58
    • /
    • 2015
  • In this study, the experimental study on Thermal Performance of Insulated Forms with Different Insulating Methods at Low Temperature. For this study, placing insulated plywood based form between two constant temperature chamber that maintaining 10℃, decrease temperature of one chamber to -10℃ and -20℃. Each of steps, maintaining period of temperature was 1 hour. After placing the form, measure temperature of opposite side of the insulated form. As a result of experiment, temperature difference of rigid urethane was lowest.

  • PDF

단열콘크리트의 레올로지 특성에 관한 실험적 연구 (An Experimental Study on the Rheology Characteristics of Insulating Concrete)

  • 류동우;지석원;전현규
    • 한국건설순환자원학회논문집
    • /
    • 제4권2호
    • /
    • pp.118-124
    • /
    • 2016
  • 본 연구는 단열성능 향상 재료의 타입별 단열콘크리트의 레올로지 특성을 분석하여 최적 유동설계 및 펌핑해석을 위한 기초자료로 활용하고자 하였다. 그 결과 경량골재 혼입시 항복응력이 큰 폭으로 감소한 것으로 나타났으며, 2 type의 경우 마이크로기포제 (MFA) + 규조토 미분말(DM)의 조합이 가장 이상적인 유동특성을 나타내었다. 또한 3 type의 경우 마이크로기포제(MFA) + 규조토 미분말(DM) + 경량골재(L)의 조합이 가장 우수한 유동특성을 나타내었다.