• 제목/요약/키워드: Insulated switchgear

검색결과 234건 처리시간 0.04초

가스절연개폐장치 고장 실태조사 연구 (Analysis on Fault for Gas Insulated switchgear)

  • 이봉희;박순규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.946-948
    • /
    • 2000
  • Recently, the reliability of switching devices for transmission & substation system is very important. Especially, the use of Gas Insulated Switchgear increase gradually. Therefore, We have investigated the fault trend of Gas Insulated Switchgear from 1985 to 1999. This paper presents the fault analysis on 154 kV, 345kV Gas Insulated Switchgear, including 25.8kV Gas Insulated Switchgear. Thus, this paper will help improve design, manufacture, construction technology and maintenance method.

  • PDF

25.8kV 고체절연스위치기어 개발 (Development of 25.8kV class solid insulated switchgear)

  • 이종혁;마지훈;유련;이재걸;원성연;이석원;김영근;길경석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.226-228
    • /
    • 2008
  • In recent years, the companies of electric power equipment for MV and HV classes trend to develop the eco-friendly insulated(solid, eco-gas, air etc.) switchgear which replaces existent SF6 gas insulated switchgear due to environmental problems such as global warming and so on. This paper makes reference to the newly developed Solid Insulated Switchgear (SIS) which uses the eco-friendly material such as epoxy for insulation. The insulation of the solid insulated switchgear (SIS) is composed of an epoxy, vacuum and air. The solid insulated switchgear (SIS) is a slate of the art product. The advantages of SIS are advanced reliability, economical efficiency, safety, maintenance free, reduction of installation area and the protection of environment. The solid insulated switchgear (SIS) is FE Analyzed such as electromagnetic, mechanical, thermal and fluid in order to find the optimal design. Thens SIS has been verified by international standard test. (IEC 62271 - 100 and so on.) As a result of this, the solid insulated switchgear (SIS) has been estimated as an alternative for eco-friendly MV class switchgear.

  • PDF

IT Enabled 친환경 고체절연 Switchgear (Eco-friendly Solid Insulated Switchgear for IT Enabled)

  • 이종혁;마지훈;유련;이재걸;탁성준;박정남;이석원;안희일;김영근;신영준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.241-243
    • /
    • 2005
  • This paper describes development of intelligent solid insulated switchgear for next generation distribution line. Nowadays, for switchgear, increased to substitute eco-friendly environment and smart ability. In relation to a project to development of intelligent solid insulated switchgear, a comparison of insulation for substitution insulation medium, to show a composition of intelligent solid Insulated switchgear and valuation on characteristics for each of module.

  • PDF

3차원 자계해석을 통한 GIS 모선의 와전류에 의한 온도 상승 (30 Magnetic Analysis on Temperature Rise Resulting from Induced Eddy current In Gas Insulated Switchgear)

  • 이방욱;손종만;강종성;서정민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2274-2276
    • /
    • 1999
  • In this work, temperature rise and eddy current distribution on the enclosure and conductor of 3 pole gas insulated switchgear were investigated using analytical and experimental measures. The design of the diameters of the conductors and the enclosures of a meal clad gas insulated switchgear is primarily based on the insulation requirements. It is very difficult problem to predict the temperature rise of enclosed switchgear due to the complexity of the phenomena of heat transfer and existence of eddy current loss. To overcome this situations, we focused on the eddy current distribution on the enclosure of switchgear caused by high current 3 pole conductor as a fundamental basis. The experimental results about temperature distribution of 3 pole gas insulated switchgear were reported and measurements are compared with predictions of three-dimensional thermal model for eddy current analysis. As a result, three dimensional numerical analysis found to be in close relationship with experimental results and thermal model is efficient to predict the abnormal temperature rise in switchgear.

  • PDF

25.8kV급 친환경 고체절연차단기(Solid Insulated Switchgear)에 대한 기계적 신뢰성(수명) 평가 (Mechanical Reliability(Life-Time) Estimation for 25.8kV Eco Solid Insulated Switchgear)

  • 이도훈;이석원;박석원;김영근;이종호
    • 전기학회논문지P
    • /
    • 제59권2호
    • /
    • pp.202-205
    • /
    • 2010
  • In this paper, mechanical reliability(Life-time) estimation method for 25.8kV SIS(Solid Insulated Switchgear) has been studied. Recently enacted KEPCO's standard includes clause that have to submit a warrantable reliability data for life-time(over B10 25 years) of an epoxy-solid insulating material. Accordingly, this research was carried out on the ALT(Accelerated Life Test) and Life-Estimation method for SIS's insulating material. Mechanical life-time estimation for SIS's insulating material is to verify reliability for tensile creep & fatigue stress, which is the major mechanical stress of SIS. This study proved that SIS's reliability for mechanical stress and established that confidence for estimation results in further verification test.

Application of Joint Electro-Chemical Detection for Gas Insulated Switchgear Fault Diagnosis

  • Li, Liping;Tang, Ju;Liu, Yilu
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1765-1772
    • /
    • 2015
  • The integrity of the gas insulated switchgear (GIS) is vital to the safety of an entire power grid. However, there are some limitations on the techniques of detecting and diagnosing partial discharge (PD) induced by insulation defects in GIS. This paper proposes a joint electro-chemical detection method to resolve the problems of incomplete PD data source and also investigates a new unique fault diagnosis method to enhance the reliability of data processing. By employing ultra-high frequency method for online monitoring and the chemical method for detecting SF6 decomposition offline, the acquired data can form a more complete interpretation of PD signals. By utilizing DS evidence theory, the diagnostic results with tests on the four typical defects show the validity of the new fault diagnosis system. With higher accuracy and lower computation cost, the present research provides a promising way to make a more accurate decision in practical application.

이동격자를 이용한 초고압 차단기 유동해석 (CFD Analysis of Gas Insulated Switchgear with Moving Grid)

  • 민병수;박일석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.737-738
    • /
    • 2002
  • To develop and improve a GIS(Gas Insulated Switchgear), the prediction of the pressure in puffer cylinder and the flow between the nozzle and the moving electrode within GIS is very important.The leading companies in GIS business issue the results of the study of flow within GIS including arc plasma. In this study, the characteristics of the flow of the GIS developed by HHI(Hyundai Heavy Industries Co. Ltd.) was investigated. To simulate the compressible flow of GIS, the CFX, a commercial CFD code, was used. With moving grid method, the movement of piston and electrode was simulated. The moving grid method was superior to the method of varying the property of cells to move an obsticle, in stability and convergencce of solution. The calculated maximum pressure within the puffer cylinder was matched with experimental data within $5{\%}$ error. The oscilation of pressure in GIS after the movement of electrode was well predicted.

  • PDF

가스절연 개폐장치 투입저항의 동특성 해석 (Dynamic Characteristics Analysis of Closing Resistors of Gas Insulated Switchgear)

  • 조해용;이성호;임성삼;이기정;김민우
    • 한국정밀공학회지
    • /
    • 제22권11호
    • /
    • pp.104-110
    • /
    • 2005
  • GIS(Gas Insulated Switchgear) is used in electric power system, to insure non conductivity, breaking capacity and operating reliability. The commercial dynamic analysis code COSMOS MOTION and 3-D modeling program SOLID WORKS were used to simulate dynamic analysis of the closing resistors of the GIS in this paper. To reduce chatter vibration of closing resistors, the motion of moving and fixed parts of closing resistors were simulated by varying the spring constant, the damping coefficient and the mass of moving and fixed parts. The simulated results were compared with experimental results. As a result, chatter vibration of closing resistors of the GIS could be reduced by using the results. These data can be used to determine the spring constant, the damping coefficient and mass of a moving part to reduce chatter vibration when the next model is developed.

당진 화력발전소용 800kV 가스절연차단기(Gas Insulated Switchgear) 고유모드해석 (The Normal Mode Analysis of 800kV Gas Insulated Switchgear(GIS) for the Dangjin Thermal Plant)

  • 신익호;송원표;권기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.363-365
    • /
    • 1999
  • 800kV GIS(Gas Insulated Switchgear) was first developed by Hyosung Corporation in Korea at Dec. 1998 and is going to be installed first in the Dangjin Thermal Plant. We intoned to verify the structural safety of 800kV GIS under seismic load. The modal analysis of 800kV GIS has been carried out to obtain the natural frequency and mode shape. PATRAN was used for mode)ing exactly 800kV GIS Geometry. 800kV GIS FE(Finite Element) model was constructed of shell elements for the enclosures and beam elements for the conductors and the support insulators NASTRAN was used for analyzing the normal modes of 800kV GIS FE model.

  • PDF

Dynamic Analysis on the Closing Resistors of Gas Insulated Switchgear

  • Cho Hae-Yong;Lee Sung-Ho;Lim Sung-Sam
    • Journal of Mechanical Science and Technology
    • /
    • 제20권10호
    • /
    • pp.1607-1613
    • /
    • 2006
  • GIS (Gas Insulated Switchgear) is used in electric power system to insure non conductivity, breaking capacity and operating reliability. In the present study, dynamic analysis on the closing resistors of the GIS has bees carried out by the commercial dynamic analysis code COSMOS MOTION and 3-D modeling program SOLID WORKS. In order to find the minimum value of chatter vibration of closing resistors, the motion of moving and fixed resistor parts of closing resistors were simulated by varying the spring constant, the damping coefficient and the mass of moving and fixed resistor parts. The simulated results were compared with experimental results. The application of the results could reduce chatter vibration of closing resistors of the GIS. These data are also useful on the development of future model GIS with minimum chatter vibration for the determinations of the spring constant, the damping coefficient and mass of a moving part.