• Title/Summary/Keyword: Instrument Control

Search Result 987, Processing Time 0.027 seconds

Experimental Research for Traction force Sensor Development on Drawing Exercise Medical Instrument (재활 및 교정을 위한 견인운동치료기의 견인측정센서 개발에 관한 실험적 연구)

  • Lee, Sang-sik;Park, Won-yeop;Lee, Choong-ho
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.2 no.2
    • /
    • pp.3-8
    • /
    • 2009
  • The traction system has been mainly used for rehabilitation and correction of patients with spine or gait diseases in orthopedics or at home. Some problems could occur in human body when patients forced their training using the traction system. So it needs to measure a traction force and control the training time. However, most of products on market have no sensor measuring traction force. Thus we designed and made a sensor detecting traction force using strain gauge, amplifier for transition to output signal and experiment devices for performance test. We carried out experiment of a sensor detecting a traction force and measured electric responses of it with respect to traction loads. Maximum error was within about 1% for experiments in static condition and the average error was about 0.7% for experiments in dynamic condition. We concluded that it is possible to use the developed sensor for measurement of traction force since the maximum output variation of a sensor detecting a traction force was about 0.3% in $0^{\circ}C-60^{\circ}C$ temperature condition.

  • PDF

The Usefulness of Al Face Block Fabrication for Reducing Exposure Dose of Thyroid Glands in Mammography (유방촬영 시 갑상샘의 피폭선량 경감을 위한 Al Face Block 제작 및 유용성에 관한 연구)

  • Hong, Eun-Ae;Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.11-17
    • /
    • 2013
  • Currently, there are many studies being conducted around the world to reduce exposure dose to radiation for patients to receive medical treatments in a safe environment. We developed and fabricated of this shield that the patients are protected from the radiation and are need of safety control during breast imaging. In this study, for breast imaging, GE Senography 2000D were used and set at SID 65cm, 28kVp, and 63mAs. The measuring instrument was Fluke's Victoreen 6000-529. And we performed Face Block on with 30 patients. The chamber on the actual thyroid glands to take CC and MLO and measure the dosage before and after wearing the Face Block. For the results, after wearing the Face Block, exposure was decreased by 53.8%-100% and 65.8% in average in CC View and by 50%-100% and 60.7% in average in MLO View. The development of the Face Block that practically decreased the exposure dose of thyroid glands, crystalline eyes during breast imaging and reduced the patients' anxiety during breast imaging. The Face Block is expected to improve patients' satisfaction and contribute to reducing patients' exposure dose, but more efforts should be made to reduce exposure dose to medical radiation.

Transareolar-Perinipple Dual Pockets Breast Augmentation (횡유륜 유두주위절개를 통한 이중포켓 유방확대술)

  • Lee, Paik Kwon;Kim, Jee Hoon;Seo, Byung Chul;Oh, Deuk Young;Rhie, Jong Won;Ahn, Snag Tae
    • Archives of Plastic Surgery
    • /
    • v.34 no.1
    • /
    • pp.93-98
    • /
    • 2007
  • Purpose: Many options are available for the incision and pocket selection in breast augmentation. Each method has its advantages and disadvantages. To leave an invisible operation scar and to achieve easier pocket dissection by the central location of the incision on the breast, we made a transareolar-perinipple incision. To overcome the disadvantages of the transareolar incision, originally advocated by Pitanguy in 1973, we modified the direction of incision line and dissection plane. Methods: To avoid the injury of 4th intercostal nerve responsible for nipple sensation, we made perinipple incision on the medial side of the nipple instead of trans-nipple incision and made the transareolar incision as 11-5 o'clock on the left side and 1-7 o'clock on the right side instead of 3-9 o'clock on both sides. To avoid the possible infection and breast feeding problem caused by the injury to the lactiferous duct, and the possible implant hernia caused by the incisions lying on a same plane of pocket dissection, we made a subcutaneous dissection just above the breast tissue medially down to the bottom of breast tissue and made a subglandular or subfascial pocket, which may avoid the injury of lactiferous duct and create different planes for skin incision and pocket dissection. Other advantages of the transareolar-perinipple incision include easier pocket dissection, less chance of hematoma, and as a result less postoperative pain because of the central location of the approach which allow finger dissection and meticulous bleeding control with direct vision, without any specialized instrument such as an endoscope or long mammary dissectors. As for pocket selection, we made dual pockets. We prefer subglandular or subfascial pocket. Also, we made a subpectoral pocket in the upper 1/4 of the pocket to add more volume on the upper part of the augmented breast, which can make aesthetically more desirable breasts in thin Asian women with small breasts. Possible disadvantages of our method are subclinical infection and scar widening, which could be overcome by meticulous operation techniques, antibiotic therapy, and intradermal tattooing. Results: From September, 2003 to August, 2005, 12 patients underwent breast augmentation using round smooth surface saline implants by our method. During the mean follow-up period of 13 months, there were no complications such as infection, hematoma, capsular contracture, and sensory change of nipple, and results were satisfactory. Conclusion: We suggest breast augmentation via transareolar-perinipple incision and dual pockets(subpectoral-subglandular or subfascial) as a valuable method in thin oriental women with small breasts.

Analysis of Elevation Variation within a Rice Paddy Field (수도작 포장 균평도의 연중 변화 분석)

  • Sung, Je-Hoon;Jang, Soon-Woo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.39 no.5
    • /
    • pp.307-314
    • /
    • 2006
  • Elevation differences within a paddy field relate strongly to plant health, crop homogeneity, and pest control. For precision agriculture (PA), the elevation within a field should be precisely controlled. We analyzed variation in elevation within two rice paddies over one crop cycle. The study took place in two rectangular plots (Field A and Field B, each $50m{\times}30m$). Elevations within the two plots were measured by a laser-equipped surveying instrument, that could determine elevations to precisions of 1 mm. The test fields were divided into grids with 30 squares; elevation was measured at the center of each $5{\times}10-m$ grid square. This study measured elevation during nine observation periods from pre-plowing to post-harvest. Descriptive statistics showed the highest elevations after plowing due to soil disturbance. One-way analysis of variance (ANOVA) revealed significant elevation differences before and after plowing and transplanting, although elevations were similar over the period of crop growth. Comparison of pre-plowing and post-harvest data showed differences in elevations, indicating that elevation changes occurred during plowing, rice transplanting, plant growth, and harvesting. In summary, the above statistical analyses indicated that elevation changes occurred due to plowing but not during the plant growth season or due to harvesting.

Characteristics of $Al_2O_3/TiO_2$ multi-layers as moisture permeation barriers deposited on PES substrates using ECR-ALD

  • Gwon, Tae-Seok;Mun, Yeon-Geon;Kim, Ung-Seon;Mun, Dae-Yong;Kim, Gyeong-Taek;Park, Jong-Wan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.457-457
    • /
    • 2010
  • Flexible organic light emitting diodes (F-OLEDs) requires excellent moisture permeation barriers to minimize the degradation of the F-OLEDs device. Specifically, F-OLEDs device need a barrier layer that transmits less than $10^{-6}g/m^2/day$ of water and $10^{-5}g/m^2/day$ of oxygen. To increase the life time of F-OLEDs, therefore, it is indispensable to protect the organic materials from water and oxygen. Severe groups have reported on multi-layerd barriers consisting inorganic thin films deposited by plasma enhenced chemical deposition (PECVD) or sputtering. However, it is difficult to control the formation of granular-type morphology and microscopic pinholes in PECVD and sputtering. On the contrary, atomic layer deoposition (ALD) is free of pinhole, highly uniform, conformal films and show good step coverage. Thus, $Al_2O_3/TiO_2$ multi-layer was deposited onto the polyethersulfon (PES) substrate by electron cyclotron resonance atomic layer deposition (ECR-ALD), and the water vapor transmission rates (WVTR) were measured. WVTR of moisture permeation barriers is dependent upon density of films and initial state of polymer surface. A significant reduction of WVTR was achieved by increasing density of films and by applying low plasma induced interlayer on the PES substrate. In order to minimize damage of polymer surface, a 10 nm thick $TiO_2$ was deposited on PES prior to a $Al_2O_3$ ECR-ALD process. High quality barriers were developed from $Al_2O_3$ barriers on the $TiO_2$ interlayer. WVTR of $Al_2O_3$ by introducing $TiO_2$ interlayer was recorded in the range of $10^{-3}g/m^2.day$ at $38^{\circ}C$ and 100% relative humidity using a MOCON instrument. The WVTR was two orders of magnitude smaller than $Al_2O_3$ barriers directly grown on PES substrate without the $TiO_2$ interlayer. Thus, we can consider that the $Al_2O_3/TiO_2$ multi-layer passivation can be one of the most suitable F-OLEDs passivation films.

  • PDF

Recent Technological Advances in Optical Instruments and Future Applications for in Situ Stable Isotope Analysis of CH4 in the Surface Ocean and Marine Atmosphere (표층해수 내 용존 메탄 탄소동위원소 실시간 측정을 위한 광학기기의 개발 및 활용 전망)

  • PARK, MI-KYUNG;PARK, SUNYOUNG
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.23 no.1
    • /
    • pp.32-48
    • /
    • 2018
  • The mechanisms of $CH_4$ uptake into and release from the ocean are not well understood due mainly to complexity of the biogeochemical cycle and to lack of regional-scale and/or process-scale observations in the marine boundary layers. Without complete understanding of oceanic mechanisms to control the carbon balance and cycles on a various spatial and temporal scales, however, it is difficult to predict future perturbation of oceanic carbon levels and its influence on the global and regional climates. High frequency, high precision continuous measurements for carbon isotopic compositions from dissolved $CH_4$ in the surface ocean and marine atmosphere can provide additional information about the flux pathways and production/consumption processes occurring in the boundary of two large reservoirs. This paper introduces recent advances on optical instruments for real time $CH_4$ isotope analysis to diagnose potential applications for in situ, continuous measurements of carbon isotopic composition of dissolved $CH_4$. Commercially available, three laser absorption spectrometers - quantum cascade laser spectroscopy (QCLAS), off-axis integrated cavity output spectrometer (OA-ICOS), and cavity ring-down spectrometer (CRDS) are discussed in comparison with the conventional isotope ratio mass spectrometry (IRMS). Details of functioning and performance of a CRDS isotope instrument for atmospheric ${\delta}^{13}C-CH_4$ are also given, showing its capability to detect localized methane emission sources.

Current Research Status of Postharvest Technology of Onion (Allium cepa L.) (양파(Allium cepa L.) 수확후 관리기술 최근 연구 동향)

  • Cho, Jung-Eun;Bae, Ro-Na;Lee, Seung-Koo
    • Horticultural Science & Technology
    • /
    • v.28 no.3
    • /
    • pp.522-527
    • /
    • 2010
  • Onion has been reported to contain various organosulfur compounds which have antibiotic and anticarcinogenic properties and flavonoid like quercetin which is a valuable natural source of antioxidants. Carbohydrates in onion constitute about 80% of dry matter, and the major non-structural carbohydrate of onion bulb is fructo-oligosaccharides, well known as fructan, followed by glucose, fructose, and sucrose. The sugar concentration is associated with dormancy and storage life of onion, occurring as decrease in glucose, fructose and fructan, particularly towards the end of storage. Forced air pre-drying for 15-20 days at room temperature is an essential procedure to reduce freezing injury and sprouting, then onion bulbs can be stored at $0^{\circ}C$ for 6 months to control sprouting and decay. Bacterial soft rot caused by $Erwinia$ and $Pseudomonas$ is the main postharvest disease when the bulbs are infected with the bacteria and stored at room temperature. Browning in sliced onion is due to oxidation of phenolic compounds by polyphenol oxidase and it can be inhibited by citric acid treatment, packing with nitrogen gas, and polyethylene film.

Quality Improvement in Patient Care Services : Obstacles and Approaches (진료의 질관리에 대한 시론 -장애와 접근-)

  • 한달선
    • Health Policy and Management
    • /
    • v.2 no.2
    • /
    • pp.112-130
    • /
    • 1992
  • Patient care services are provided to individual patients in response to their health needs produced by illnesses or injuries. The services are often addressed to very serious conditions, and also they constitute the most expensive component of health care services. Therefore, the importance of quality is emphasized, but there are many indications that patient care quality is far from a satisfactory state in most of the countries. Based upon this observation, it is attempted to examine obstacles and approaches to quality improvement in patient care services. In doing so, following Taguchi's(1986) definition of product quality, quality of patient care services is conceived of as better when the less is the sociental loss attributalbe to variability of intended function and harmful side effects they emhibit after being delivered. Some distinguishing features of medical care sector pose difficulties in implementing effective quality improvement programs in patient care services. Nevertheless, newly proposed method of quality management, based on industrial quality management approach, seems to have a great deal of potential to effectively cope with such difficulties. This method, unlike the traditional approach to quality assurance, focuses on total organisational processes, not individuals, as the obproach to quality assurance, focuses on total organizational processes, not individuals, as the objects of quality improvement; variation, not comparison with standards, in quality measurement; and continuous improvement, not removing only bad quality care, as an ideal. Prerequisite to a successful use of any quality mangement method is motivating providers to improve quality. Conceivable approaches for such motivation are self-regulation, external controls and promotion of competition. Since these approaches are not mutually exclusive, they may be employed in an appropriate combination. In Korea, medical care providers are now functioning under the circumstances where they have little reason for making efforts to improve quality of their services. Once these circumstantial conditions are changed to exert pressures on providers to improve quality, the use of adequate quality management method becomes an issue. In this connection, much attention shoould be directed to the newly proposed method described above. In all these efforts for improving quality of patient care services, health insurance would be able to play a pivotal role. Poviders of medical care, buth indiciduals and organizations, are usually very responsive to the measures that affect their financing, and thus health insurance can be a strong instrument for motivationg providers to improve quality. Also, the insurance continuously acquires data on patient care, which could be processed to produce information required to effective quality control.

  • PDF

Effect of Cudrania tricuspidata Leaf Powder Addition on the Quality of Sponge Cakes (꾸지뽕잎 분말을 첨가한 스펀지 케이크의 품질 특성)

  • Lee, Jun Ho;Son, Seok Min
    • Food Engineering Progress
    • /
    • v.15 no.4
    • /
    • pp.376-381
    • /
    • 2011
  • The baking performance of Cudrania tricuspidata leaf powder as a value-added food ingredient was investigated in a model system of sponge cakes. Cudrania tricuspidata leaf powder was incorporated into cake batter at 5 levels (0, 5, 10, 15, and 20%, w/w) by adding equivalent amount based on total weight of wheat flour. The specific volume, height, moisture content, volume index, and symmetry index of sponge cakes decreased significantly with the increase in Cudrania tricuspidata leaf powder content (p < 0.05). Sponge cakes became darker and firmer with increase in Cudrania tricuspidata leaf powder content (p < 0.05), as indicated by decrease in the $L^*$ and increase in the firmness measured by the texture measuring instrument. Total polyphenol content also increased gradually as the Cudrania tricuspidata leaf powder content increased. Finally, the consumer acceptance test indicated that addition of Cudrania tricuspidata leaf powder up to 10% in the formulation of sponge cakes did not significantly influence the consumers' acceptability with respect to taste and flavor. In addition, the overall acceptability was not different from each other for control and 5% sample (p > 0.05).

A Study on How Height and Weight Affects Glomerular Filtration Rate (신장과 체중의 변화가 사구체 여과율에 미치는 영향)

  • Park, A Rang;Choi, Jong Sook;Lee, Young Hee;Jung, Woo Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.40-44
    • /
    • 2019
  • Purpose Glomerular filtration rate (GFR) is an important index for evaluation of renal function, renal disease diagnosis and progress monitoring. Therefore, accurate measurement of GFR is clinically important. Among the factors that affect the GFR result, there have been many discussions on the methods such as the correction of the kidney depth, net syringe count, and the method of setting the ROI. However there has been no consideration of counting in the most basic factors like height and weight measurement. In this study, we investigate how height and weight changes affects the result of GFR and review the importance of standardized body measurements. Materials and Methods Fifty patients who underwent GFR test were randomly sampled and examined for changes in height and body weight within one month. From the normal patients without renal disease to the patients with severely decreased GFR, we applied the GFR formula of Gate with varying height and weight. Results: The result showed variation of the height at maximum three centimeters and six kilograms of weight. The first calculation of GFR was done with fixed height value and control variable as weight. Weight was incremented by one kilogram each time up to six kilograms. The GFR showed increased result with increasing weight. The result of GFR showed ten percent increase with six kilograms of weight increase. On the other hand, when height value was incremented by one centimeter up to three centimeters showed decreased GFR result with fixed weight value. Up to three centimeters of height increase showed two percent of decreased GFR with fixed weight. Conclusion This study showed varying GFR result when height and weight changes. Therefore it is clinically crucial not only to maintain and manage body measuring instrument but also to have a standardized measurement methods to derive accurate measured values and to achieve reproducibility.