• Title/Summary/Keyword: Instantaneous temperature

Search Result 210, Processing Time 0.029 seconds

Experimental Study on Single Bubble Growth Under Subcooled, Saturated, and Superheated Nucleate Pool Boiling

  • Kim Jeong-Bae;Lee Jang-Ho;Kim Moo-Hwan
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.692-709
    • /
    • 2006
  • Nucleate pool boiling experiments with constant wall temperature were performed using pure R1l3 for subcooled, saturated, and superheated pool conditions. A microscale heater array and Wheatstone bridge circuits were used to maintain the constant wall temperature and to measure the instantaneous heat flow rate accurately with high temporal and spatial resolutions. Images of bubble growth were taken at 5,000 frames per second using a high-speed CCD camera synchronized with the heat flow rate measurements. The bubble geometry was obtained from the captured bubble images. The effect of the pool conditions on the bubble growth behavior was analyzed using dimensionless parameters for the initial and thermal growth regions. The effect of the pool conditions on the heat flow rate behavior was also examined. This study will provide good experimental data with precise constant wall temperature boundary condition for such works.

Cyclic Creep Strain of Cu Pure Metal (CU 순금속의 사이클릭 크리프 변형)

  • Jeong, S.U.;Lee, H.S.
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.194-199
    • /
    • 2000
  • The creep rate is affected by the temperature and in fact. if the temperature above $T_M/2(T_M:melting\;point)$. The aim of the present investigation is to study the relationship of static creep and cyclic creep behavior of pure copper and the formulation of these phenomena with the special attention to the instantaneous strain. strain rate from time and number of cycles have the same inclination Steady state creep rate depend upon maximum stress and can be expressed as linear function according to Power law creep equations Creep rupture time has relation with creep rate. and it make a group represented as the same direct line regardless of max stress, stress ratio and the temperature. Initial strain effect on continuous creep deformation. and have guantitative relationship between elastic and Plastic strain. LMP have similar tendency than OSDP and MHP according to temperature

  • PDF

Design of Over Current Sequence Control Algorithm According to Lithium Battery Fuse Temperature Compensation (리튬 배터리 퓨즈 온도 보상에 따른 과전류 시퀀스 제어 알고리즘 설계)

  • Song, Jung-Yong;Huh, Chang-Su
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.1
    • /
    • pp.58-63
    • /
    • 2019
  • Lithium-ion batteries used for IT, automobiles, and industrial energy-storage devices have battery management systems (BMS) to protect the battery from abnormal voltage, current, and temperature environments, as well as safety devices like, current interruption device (CID), fuse, and vent to obtain positive temperature coefficient (PTC). Nonetheless, there are harmful to human health and property and damage the brand image of the manufacturer because of smoke, fire, and explosion of lithium battery packs. In this paper, we propose a systematic protection algorithm combining battery temperature, over-current, and interconnection between protection elements to prevent copper deposition, internal short circuit, and separator shrinkage due to frequent and instantaneous over-current discharges. The parameters of the proposed algorithm are suggested to utilize the experimental data in consideration of battery pack operating conditions and malicious conditions.

Growth Inhibitory Factors of Italian Ryegrass (Lolium multiflorum Lam.) after Broadcasting under Growing Rice from 2014 to 2015 (2014 / 2015년 이탈리안 라이그라스 (Lolium multiflorum Lam.)의 벼 입모 중 파종 재배시 생육저해 요인 분석)

  • Kim, Young-Jin;Choi, Ki-Choon;Lee, Sang-Hak;Jung, Jeong-Sung;Park, Hyung-Soo;Kim, Ki-Yong;Ji, Hee-Chung;Lee, Sang-Hoon;Choi, Gi-Jun;Kim, Won-Ho
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.36 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • The growth of Italian ryegrass (IRG) after wintering was very low in 2015 when IRG was broadcasted under growing rice in fall of 2014. To determine growth inhibitory factors of IRG, we examined the growth conditions of IRG in Nonsan region and meteorological conditions in Daejeon nearby Nonsan. Minimum temperature and maximum instantaneous wind speed on Feb. $8^{th}$ and $9^{th}$ of 2015 after wintering of IRG were $8.8^{\circ}C$, 10.7 m/s and $12.4^{\circ}C$, 9.6m/s, respectively. Air temperature was suddenly dropped due to strong wind with snow showers, which had unfavorable effect on root growth of IRG exposed at the soil surface. The minimum temperature and maximum instantaneous wind speed on Feb. $12^{th}$, $13^{th}$, and $14^{th}$ of 2015 were $4.1^{\circ}C$, 11.6 m/s, $-5.6^{\circ}C$, 10.3 m/s, and $-4.7^{\circ}C$, 7.5 m/s, respectively. The growth circumstance of IRG was not good because soil was dried due to drought continued from January. The minimum temperature and maximum instantaneous wind speed on Feb. $26^{th}$, $27^{th}$, and $28^{th}$ of 2015 were $1.8^{\circ}C$, 13.7 m/s, $-3.5^{\circ}C$, 10.6 m/s, and $4.1^{\circ}C$, 6.8 m/s, respectively. The number of wilting of IRG was more than 59% until Mar. $3^{rd}$ of 2015. IRG faced irreparable environment (low minimum temperatures and extreme instantaneous wind speeds) for 9 days from Mar. $4^{th}$ to Mar. $12^{th}$ of 2015. The main reason for the decrease of IRG productivity was collection delay of rice straw after rice harvest because there was continuous rain between Oct. and Nov. of 2014. For this reason, weakly grown IRG under rice straw was withered after wintering. IRG was withered by frost heaving, drought, and instantaneous wind speed in the spring. Furthermore, the root of IRG was damaged while growing in excess moisture in the surface of paddy soil during the winter season due to rain.

Strategy for molecular weight distribution control in a batch polymerization reactor system (회분식 중합 반응기에서의 분자량 분포제어 전략)

  • 김인선;유기윤;이현구
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.766-771
    • /
    • 1993
  • A mathematical model is developed to represent the batch reactor for free radical polymerization of PMMA The model is validated by comparing the simulation result with the experimental data. A computational scheme is proposed to determine the trajectory of the reactor temperature that will produce polymer product having the desired molecular weight distribution. For this instantaneous number average chain length and polydispersity are introduced to calculate the reactor temperature. The former is assumed to be a second order polynomial of the sum of the living and dead polymer concentrations. Various reactor temperature, trajectories are observed depending on the reactor conditions and prescribed molecular weight distributions. Fuzzy and PID control algorithms are applied to trace the reactor temperature trajectory. While the PID control gives rise to an overshoot when the trajectory changes its direction, the fuzzy controller yields a more satisfactory performance because it secures information on the trajectory pattern.

  • PDF

Study of the Thermal Stresses and Residual Stresses due to Welding in Hull Constructruction -Thermal Stresses due to Welding- (선체건조(船體建造)에 있어서 용접공작(熔接工作)으로 인(因)한 열응력(熱應力) 및 잔류응력(殘留應力)에 대(對)한 고찰(考察) -용접작업(熔接作業)으로 인(因)한 열응력해석(熱應力解析)-)

  • Hyo-Chul,Kim;Zae-Geun,Kim
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.13 no.1
    • /
    • pp.25-34
    • /
    • 1976
  • Analytical solutions for the transient temperature and quasi-static thermal stresses which arise in thin plates subjected to an instantaneous point source of heat have been investigated. And the solutions have been extended to the case of a moving source of heat with the aid of the Duhamel's superposition integral. For finite disk an experiment was conducted, the measured temperature histories show a good agreement with the theoretical temperature histories, And the histories of thermal stresses show a good qualitative agreement with the physical phenomena. And also we can find out that the maximum temperature and thermal stresses and their location can be estimated by using the solutions for infinite plates instead of the solutions for a finite plate. The solutions can be used for the problems such as a welding or line heating in a hull construction.

  • PDF

A Calculation Method on Heat Flux from Ondol Floor Surface (온돌면(溫突面)의 방열량(放熱量) 산정방법(算定方法)에 관한 연구(硏究))

  • Sohn, Jang Yeul;Ahn, Byung Wook;Pang, Seung Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.1 no.2
    • /
    • pp.173-181
    • /
    • 1989
  • Until recently there was a lack of reliable performance data for the design and operation of Ondol heating systems. This paper presents a calculation method on heat flux from Ondol floor surface. Total heat flux from floor consists of radiation and convection component. In order to analyse the characteristics of both radiation and convection heat flux, each surface temperature is measured and several temperatures near each wall are measured vertically and horizontally in a practical Ondol heating space. Radiation heat flux is calculated and analysed by Gebhart's Absorption Factor Method with the consideration of instantaneous radiant exchanges. Convection heat output is derived from the vertical temperature profiles near floor. The vertical temperature profiles could be expressed by nonlinear regression equation models and convection coefficients could be estimated by the equations. As a result, radiation, convection and total heat flux are suggested by the expression of difference between floor surface and room air temperature.

  • PDF

Interference Temperature based Frequency Sharing Scheme for Multiple Cognitive Radio Users (간섭 온도 기만의 다중 Cognitive Radio 사용자를 위한 주파수 공유 방안)

  • Kim, Seung-Wang;Kim, Hye-Ryeong;Choe, Sang-Ho
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.12
    • /
    • pp.72-81
    • /
    • 2009
  • In this paper, we investigate a spectrum sharing scheme based on the interference temperature (IT), that is a recently introduced receiver-centric metric by FCC. We extend the existing frequency sharing procedure for single CR to the one for multiple CRs (or secondary users, SUs). In the proposed interference model, we consider the practical operating characteristics of primary users (PUs), stochastically activated (ON)/deactivated (OFF) at the time axis, and analyze quantitatively the CR user capacity based on the model. We define the instantaneous capacity for idle time-slot channel allocation and the mean capacity averaging this instantaneous capacity and use them for a proper frequency sharing. Apart from existing schemes, the proposed frequency sharing scheme changes the frequency parameters adaptively depending on the channel characteristics and does not need any sensing information from PUs. Through computer simulation, we verify the proposed model.

Study on the single bubble growth at saturated pool boiling (포화상태 풀비등시 단일기포의 성장에 관한 연구)

  • Kim, Jeong-Bae;Lee, Han-Choon;Oh, Byung-Do;Kim, Moo-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1933-1938
    • /
    • 2004
  • Nucleate boiling experiments with constant wall temperature of heating surface were performed using R113 for almost saturated pool boiling conditions. A microscale heater array and Wheatstone bridge circuits were used to maintain a constant wall temperature condition and to measure the heat flow rate with high temporal and spatial resolutions. Bubble images during the bubble growth were taken as 5000 frames a sec using a high-speed CCD camera synchronized with the heat flow rate measurements. The geometry of the bubble during growth time could be obtained from the captured bubble images. The bubble growth behavior was analyzed using the new dimensionless parameters for each growth regions to permit comparisons with previous results at the same scale. We found that the new dimensionless parameters can describe the whole growth region as initial and later respectively. The comparisons showed good agreement in the initial and thermal growth regions. The required heat flow rate for the volume change of the observed bubble was estimated to be larger than the instantaneous heat flow rate measured at the wall. Heat, which is different from the instantaneous heat supplied through the heating wall, can be estimated as being transferred through the interface between bubble and liquid even with saturated pool conditions. This phenomenon under a saturated pool condition needs to be analyzed and the data from this study can supply the good experimental data with the precise boundary condition (constant wall temperature).

  • PDF

Temperature Distribution and Thermal Stresses of Infinite Plate due to Tandem Arc Welding (Tandem熔接으로 因한 溫度分布 및 熱應力)

  • Kim, Hyo-Chul;Lee, Jun-Yeol
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.14 no.3
    • /
    • pp.5-12
    • /
    • 1977
  • In shipyard production processes, lots of steel plates are assembled by welding. Some rectangular steel plates are buttwelded to build a large block in panel production lines. There are some advantages to take the tandem arc welding in butt joints of rectangular plates with respect to welding speed. Hence, the thermal stresses and the temperature distribution of the tandem arc welding are studied in this paper. The solutions in the case of the infinite plate with two instantaneous point heat sources have been obtained. And then the solutions have been extended to the case of two moving heat sources corresponding to the tandem arc welding with the aid of Duhamel's superposition integral. It was found that the temperature distribution was good agreement with the results of the experiments by Rosenthal and Park and the thermal stresses calculated were acceptable with respect to a physical phenomenon. These solutions are able to be applied to the problem such as a line heating.

  • PDF