• 제목/요약/키워드: Instantaneous compensation

검색결과 117건 처리시간 0.031초

Graphical Representation of the Instantaneous Compensation Power Flow for Single-Phase Active Power Filters

  • Jung, Young-Gook
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1380-1388
    • /
    • 2013
  • The conventional graphical representation of the instantaneous compensation power flow for single-phase active power filters(APFs) simply represents the active power flow and the reactive power flow which flowing between the power source and the active filter / the load. But, this method does not provide the information about the rectification mode and the compensation mode of APFs, especially, the loss for each mode was not considered at all. This is very important to understand the compensation operation characteristics of APFs. Therefore, this paper proposes the graphical representation of the instantaneous compensation power flow for single-phase APFs considering the instantaneous rectification mode and the instantaneous inversion mode. Three cases are verified in this paper - without compensation, with compensation of the active power 'p' and the fundamental reactive power 'q', and with compensation of only the distorted power 'h'. To ensure the validity of the proposed approach, PSIM simulation is achieved. As a result, we could confirm that the proposed approach was easy to explain the instantaneous compensation power flow considering the instantaneous rectification mode and the instantaneous inversion mode of APFs, also, Total Harmonic Distortion(THD)/Power Factor (P.F) and Fast Fourier Transform(FFT) analysis were compared for each case.

3상 4선 계통에서의 순시전력 보상이론 (Instantaneous Power Compensation Theory in Three-phase Four-wire Systems)

  • 김효성
    • 전력전자학회논문지
    • /
    • 제11권2호
    • /
    • pp.172-183
    • /
    • 2006
  • 본 논문은 Akagi에 의해 발표된 p-q 이론과 Nabae 및 Peng에 의하여 발표된 크로스벡터 이론의 대비를 통하여 3상 4선 계통에서 순시전력보상방법을 분석한다. 3상 3선 계통에서 영상성분 전압이 없는 경우 두 이론은 똑같다. 그렇지만 3상 4선 계통에서 영상성분 전압과 전류가 포함되는 경우, 두 이론은 순시무효전력과 순시유효전력을 달리 정의한다. 본 논문에서는 이론적 분석과 컴퓨터 시뮬레이션을 바탕으로 영상성분 전압과 영상성분 전류가 존재하는 3상 4선 계통에서 에너지 저장요소의 필요 없이 무효전력만의 보상을 통하여 계통의 중성선 전류를 완벽히 제거할 수 있는 순시전력보상방법을 제시한다.

제어 자유도를 한 차원 증가시킨 순시무효전력 보상이론 (Instantaneous Reactive Power Compensation Theory Increasing The Control Freedom One Degree Higher)

  • 김효성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2481-2483
    • /
    • 1999
  • This paper proposed the p-q-r coordinate system where the instantaneous active power p, and the two instantaneous reactive powers $q_{q}$, $q_{r}$ were defined. The three power components are linearly independent, so the compensation for the two instantaneous reactive powers leads to control the two components of the current space vector. With the theory, the neutral current of a three-phase four-wire system can be eliminated by only compensating the instantaneous reactive power using no energy storage element.

  • PDF

순시무효전력 보상에 의한 중성선 전류의 제거 (Eliminating the Neutral Current by the Instantaneous Reactive Power Compensation)

  • 김효성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.131-133
    • /
    • 1998
  • This paper, proposed the p-q-r coordinate system where the instantaneous active power p, and the two instantaneous reactive powers $q_{q}$, $q_{r}$ were defined. The three power components are linearly independent, so the compensation for the two instantaneous reactive powers leads to control the two components of the current space vector. With the theory, the neutral current of the three-phase four-wire system can be eliminated by only compensating the instantaneous reactive power using no energy storage element.

  • PDF

배전용 정지형 보상기의 상태관측기를 이용한 순시 유효/무효전력 보상 (Instantaneous Active/Reactive Power Compensation of Distribution Static Compensator using State Observer)

  • 김형수;최종우
    • 전기학회논문지
    • /
    • 제57권8호
    • /
    • pp.1377-1382
    • /
    • 2008
  • DSTATCOM(distribution static compensator) is one of the custom power devices, and protects a distribution line from unbalanced and harmonic current caused by non-linear and unbalanced loads. Researches about DSTATCOM are mainly divided two parts, one is the calculation of compensation current and the other part is the current control. Conventional researches use a LPF(low pass filter) to eliminate ripple component at the calculation of compensation current. But this method has a problem that LPF's characteristics restrict the compensation performance of instantaneous active and reactive power. This paper proposes a calculation of compensation current using state observer that can be a counterproposal of conventional methods using LPF. Improved performance of instantaneous active and reactive power compensation was shown by experiments.

DSTATCOM의 순시 유효전력 보상을 이용한 선로의 전류 개선 (Improvement of line Current using Instantaneous Real Power Compensation of DSTATCOM)

  • 정수영;김태현;문승일;권욱현
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권7호
    • /
    • pp.327-332
    • /
    • 2002
  • In this paper, conventional reactive power compensation is defined and instantaneous real control concept for shunt converters is proposed. This equipment incorporates the compensation function of harmonics at the distribution line by nonlinear load. These methodologies are applied to IEEE 13 distribution system with the modeling of nonlinear load using EMTEDC/PSCAD package. Simulation with EMTDC results presented to confirm that the new approach has better performance than those obtained by controllers based on traditional concepts of reactive power compensation.

가변 속도 드라이버 부하에 대한 순시 전력 보상을 이용한 복합형 전력 필터의 설계와 시뮬레이션 (A Design and Simulation of Hybrid Power Filter for ASD Loads Based on Instantaneous Power Compensation Theory)

  • 조진호
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2000년도 춘계학술대회논문집 - 한국공작기계학회
    • /
    • pp.385-390
    • /
    • 2000
  • This paper deals with the design and simulation of the hybrid power filter to compensate reactive power and harmonic components of nonlinear load. Control target is a 3-phase diode full bridge rectifier with L-R-C nonlinear load, this load is assumed adjustable speed driver(ASD). The hybrid filter consists of a shunt active filter, shunt passive filters and series inductors. Control algorithm is based on instantaneous power compensation theory proposed by H.Akagi and etc. The result from simulation shows the hybrid filter is superior than other filters on the point of compensation performance and low cost. The PSCAD/EMTDC 3.0 is used as simulation tools.

  • PDF

전압 Sag와 Surge에 대한 순시보상 기능을 갖는 PWM Buck AC-AC 컨버터 (A PWM Buck AC-AC Converter with Instantaneous Compensation for Voltage Sag and Surge)

  • 최남섭
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.197-200
    • /
    • 2001
  • This paper presents a PWM buck AC-AC converter with instantaneous compensation for input voltage sag and surge. The presented converter use commercial IGBT modules and its output voltage is regulated so as to remain constant AC output voltage. The feedforward control technique is also proposed to establish instantaneous duty level change whereby stable output voltage will be retained. This paper show the characteristics and control algorithm of the converter through various PSPICE simulations.

  • PDF

아날로그 적분기를 이용한 맥동전압 보상형 순시추종 PWM 제어기를 적용한 인버터 (Ripple Voltage Compensation Instantaneous Follow Controller of Inverter by using Analog Integrator)

  • 라병훈;이현우;김광태
    • 전력전자학회논문지
    • /
    • 제9권4호
    • /
    • pp.381-389
    • /
    • 2004
  • 본 논문에서는 입력단 커패시터를 제거한 인버터의 제어에 아날로그 적분기를 이용한 새로운 비선형 제어 기법인 순시보상형 PWM 제어회로를 적용하고 있다. 비선형 순시보상형 PWM 제어기는 순시 입력전압의 변동에 대한 보상과 제어기준값에 대한 추종이 스위칭 한 주기 내에서 이루어지는 다이나믹하고 강인한 응답성을 가지고 있으며, 아날로그 소자를 사용하고 있어 제어회로가 간단하면, 인버터 입력 맥동전압을 보상함으로 대형의 평활용 커패시터가 필요치 않아서 소형, 저가형으로 부피가 적은 인버터를 제작 할 수 있다는 장점을 가지고 있다. 이러한 장점을 가지고 있는 순시보상형 PWM 제어 인버터를 기존의 VVVF 제어형 전동기 인버터 시스템을 대치하여 저가이고 소형의 인버터 시스템으로 제안하고 실험을 통하여 우수한 동작특성을 확인하고 있다.

에너지저장요소를 사용하지 않는 전력보상기에 의한 중성선 전류의 제거 (Eliminating the Neutral Current by the Power Compensator without using Energy Storage Elements)

  • 김효성
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권6호
    • /
    • pp.330-335
    • /
    • 1999
  • This paper proposed the p-q-r coordinate system where the instantaneous active power p, and the two instantaneous reactive powers qq, qr were defined. The three power components are linearly independent, so the compensation for the two instantaneous reactive powers leads to control the two components of the current space vector. With the theory, the neutral current of a three-phase four-wire system can be eliminated by only compensating the instantaneous reactive power using no energy storge element.

  • PDF