• Title/Summary/Keyword: Instantaneous Power Theory

Search Result 62, Processing Time 0.026 seconds

A New Scheme for Compensation of Unwanted Components of Instantaneous Load Power

  • Wong, Man-Chung;Han, Ying-Duo;Leong, Heng-San;Sio, Hon-Pan
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.888-893
    • /
    • 1998
  • In practice, not only the load current but also the load voltage may contain asymmetric and harmonic components. Instantaneous power using p-q theory is analyzed to have compensation of reactive power, harmonics and asymmetry at the same time. In this paper, the limitation of p-q theory by using only shunt or series active filter is analyzed. A new scheme is proposed to solve the above issues.

  • PDF

The Generalized Instantaneous Power Theory Using Mapping Matrices (맵핑 매트릭스를 사용한 일반화 순시전력 이론)

  • Kim, Hyo-Sung;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.1930-1932
    • /
    • 1997
  • Instantaneous active/reactive powers are defined in three phase four wire systems. The definition can be generally applicable to any source conditions and load conditions including nonlinear circuits. The zero-sequence power resulted from the zero-sequence voltage and zero-sequence current between two sub-systems affects both to the instantaneous active and reactive powers. The zero-sequence current can be controlled by compensation of the reactive power without power storage elements.

  • PDF

Three-Phase Six switch Z-source rectifier with active power filtering capability based on instantaneous reactive power theory (순시 무효전력 이론 기반의 능동전력필터 기능을 가지는 삼상 지-소스 정류기)

  • ANVAR, IBADULLAEV;Hong, Seung-Pyo;Lim, Young-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.365-366
    • /
    • 2015
  • Shunt active power filter is a complete current source which can provide an effective and adjustable solution for elimination of harmonic currents in power system. Its performance depends on strategy employed in reference current generation, control technique and topology of converter used in the design.[1-2]. In this paper Three Phase Six switch Z-source rectifier with active power filtering capability based on instantaneous reactive power theory is described. Thanking to the theory power factor and THD value are significantly improved. Experiment results and conclusions are presented.

  • PDF

Eliminating the Neutral Current by the Power Compensator without using Energy Storage Elements (에너지저장요소를 사용하지 않는 전력보상기에 의한 중성선 전류의 제거)

  • Kim, Hyo-Seong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.6
    • /
    • pp.330-335
    • /
    • 1999
  • This paper proposed the p-q-r coordinate system where the instantaneous active power p, and the two instantaneous reactive powers qq, qr were defined. The three power components are linearly independent, so the compensation for the two instantaneous reactive powers leads to control the two components of the current space vector. With the theory, the neutral current of a three-phase four-wire system can be eliminated by only compensating the instantaneous reactive power using no energy storge element.

  • PDF

Three-Phase Three-Wire Active Power Filter with a Detection Method of Instantaneous Positive Sequence Voltage (정상분 순시전압 검출기법을 이용한 3상 3선 능동전력필터 시스템)

  • 曺 在 延;鄭 榮 國;任 永 徹
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.2
    • /
    • pp.178-185
    • /
    • 2002
  • This paper describes the implementation of three-phase three-wire active power filter system with a instantaneous PSD for distorted and unbalanced power conditions. The positive sequence voltage of the distorted and the unbalanced power system is calculated by the Instantaneous PSD, and phase transformation matrix of the instantaneous power theory is achieved with detected positive sequence voltage. Finally, the proposed method is experimented and tested under unbalanced nonlinear load as well as unbalanced /distorted condition in power system.

A Study on the Decoupled Control of the Active and Reactive Power using Instantaneous Power Control Theory (순시전력 제어 이론을 이용한 유/무효전력의 독립제어에 관한 연구)

  • Kim, Eung-Sang;Kim, Ji-Won;Kim, Yeong-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.6
    • /
    • pp.678-682
    • /
    • 1999
  • In this paper, we propose the algorithm which can control active power and reactive power independently in Battery Energy Storage System. The proposed algorithm is based on the instantaneous power theory that the inner product of the voltage vector and current vector represents the active power and the cross product of those represents the reactive power, and it can control active power and reactive power independently. To verify the validity of the proposed algorithm, we make model of the real power system in th KERI and simulate this algorithm. As a result of this simulation, we verified that the proposed algorithm can control active power and reactive power independently.

  • PDF

A study on the Reactive Power Compensation using Instantaneous Power for Self Commutated Static Var Compensator (순시전력을 이용한 자려식 SVC의 무효전력보상에 관한 연구)

  • Eum, Sang-O;Kim, Jong-Yun;Jeon, Nae-Suck;Park, Chan-Kun;Lee, Sung-Geun;Kim, Yoon-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1206-1208
    • /
    • 2000
  • The Static var compensators(SVC) are intensively studied to realize high performance power equipment for electric power systems. Rapid and continuous reactive compensation by the SVC contributes to voltage stabilization, power oscillation damping, overvoltage suppression, minimization of transmission losses and so on. In this paper, instantaneous power vector theory which can expresses the instantaneous apparent power vector is proposed to control reactive power. The validity of the proposed method is confirmed by simulation studies.

  • PDF

A Simple Instantaneous Power Theory and Modified Compensation Performance Evaluation of Active Power Filters (능동전력필터의 간단한 순시전력이론과 수정된 보상성능 평가법)

  • Jung, Y.G.;Yoo, K.H.;Kim, Y.C.;Yang, S.H.;Kim, W.Y.;Lim, Y.C.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2549-2552
    • /
    • 1999
  • The fictitious power theory in time domain is very easy to understand, but power analyzing time of active power is increased, because power is analyzed using signal techniques based on the correlation between voltage and current waveforms. Also, conventional methods in time/frequency domain to evaluate the compensation performance of active power filters are not provided easy solutions. So, the authors have previously proposed 3-D current coordinates which is composed into active component, fundamental reactive component and distorted component of nonlinear loads current. This method has excellent performance, but can not evaluate the characteristics of nonlinear load current whether inductive or capacitive. Therefore, To overcome problems mentioned previously, this paper deals with the simple instantaneous power theory and the modified 3-D current coordinates for evaluating the compensation performance of active power filters. To confirm the validity, active power filters simulator is developed using C-language. From the simulation, results are discussed their utility.

  • PDF

A new ultrasonic power generator using instantaneous current resultant control-based inverter and its control system

  • Kim, Dong-Hee;Kim, Young-Seok;Yoo, Dong-Wook;Kim, Yo-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.631-636
    • /
    • 1987
  • The design of ultrasonic transducer energy processing systems requires highly reliable command featuring mechanical frequency tracking and constant velocity control of the ultrasonic transducer with an acoustic load. This paper presents a new conceptional instantaneous current resultant control base high-frequency inverter using self turn-off devices driving an electrostrictive ultrasonic transducer system and its optimum control technique, which is implemented by feed-back of the ultrasonic transducer applied voltage and instantaneous velocity of the transducer vibrating system through a Phase-Locked-Loop control scheme. The feedback voltage corresponding to instantaneous velocity is averaged over a half-period with respect to constant amplitude/constant velocity control strategy. Described are the theory of this signal detection technique and the experimental set-up.

  • PDF