• 제목/요약/키워드: Instantaneous Phase

검색결과 328건 처리시간 0.028초

Space Vector Modulated Three-Phase Soft-Switching Active Rectifier and Its Performance Evaluations

  • Fujii Yuma;Ahmed Tarek;Imamura Kosuke;Hiraki Eiji;Nakaoka Mutsuo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.213-215
    • /
    • 2003
  • This paper presents an instantaneous space vector modulated voltage source type three-phase soft-switching PFC rectifier using a single auxiliary resonant DC Link snubber for alternative energy utilizations. in the first place, the operating principle of an active auxiliary resonant DC link snubber circuit is described including its unique features. In the next place, the simulation analysis of three-phase soft-switching PWM rectifier is implemented, and the operating performances or the three-phase voltage-fed PWM rectifier treated here, which can operate under the conditions of sinewave line current shaping and utility power factor are evaluated and discussed on tile basis of this simulation results.

  • PDF

SRM의 정밀속도제어를 위한 순시스위칭각 제어방식 (Instantaneous Switching-Angle Control Scheme for Precise Speed Control of an SRM)

  • 안진우;오석규;황영문
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.454-459
    • /
    • 1997
  • The good features of a switched reluctance motor(SRM) are appreciated by the appliance manufactures. And it is spread into a commercial and industries market. The few disadvantage of the motor is higher torque ripple and noise. This paper proposes an instantaneous torque control scheme to control a speed precisely. It adapts phase-locked loop (PLL) technique to control speed precisely. In this control scheme, the phase detector signal of the PLL regulates the switching dwell angle flexibly and the loop filter's signal controls adaptively the instantaneous switching voltage. Experimental results show that drive performance is good with low torque ripple.

  • PDF

에너지저장요소를 사용하지 않는 전력보상기에 의한 중성선 전류의 제거 (Eliminating the Neutral Current by the Power Compensator without using Energy Storage Elements)

  • 김효성
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권6호
    • /
    • pp.330-335
    • /
    • 1999
  • This paper proposed the p-q-r coordinate system where the instantaneous active power p, and the two instantaneous reactive powers qq, qr were defined. The three power components are linearly independent, so the compensation for the two instantaneous reactive powers leads to control the two components of the current space vector. With the theory, the neutral current of a three-phase four-wire system can be eliminated by only compensating the instantaneous reactive power using no energy storge element.

  • PDF

회전좌표계를 이용한 단상능동전력필터의 제어방법에 관한 연구 (A study on the Control Method of Single-Phase APF Using RRF Method)

  • 김영조;허진석;김영석
    • 전력전자학회논문지
    • /
    • 제8권6호
    • /
    • pp.576-584
    • /
    • 2003
  • 본 논문에서는 비 선형 단상부하에 의해 발생하는 전류 고조파를 보상하기 위한 단상능동전력필터의 새로운 제어방법을 제안한다. 부하전류에 시간지연을 주어 임의의 두 번째 상을 생성한 후 단상시스템을 두 상을 갖는 시스템으로 만들어 복소계산을 가능하게 한다. 기존의 방법은 부하전류를 1/4 T(T는 기본파의 주기) 만큼 지연시켜서 가상의 상을 만들었지만, 본 논문에서 제안하는 방법은 저역통과필터가 상 지연의 특성을 가지는 것을 이용하여 필터를 통과한 지연된 위상을 가진 새로운 신호를 두 번째 상으로 이용하였다. 두 개의 위상이 다른 상이 존재하므로 고조파 전류의 순시계산이 가능하게 된다. 기존의 고정좌표계를 이용하여 순시무효전력이론을 적용하지 않고, 본문에서는 전원주파수에 동기하는 회전좌표계를 사용하여 순시계산을 하였고, 보상전류 지령치를 구하였다. 전류원으로 사용되는 RL부하에 대하여 시뮬레이션과 실험을 수행하였고, 제안된 제어법의 유효성을 입증하였다.

공진 DC Link 순시 정현파 전류 추종형 인버터를 이용한 유도전동기 제어시스템 (Instantaneous sinusoidal currant tracking mode inverter with quasi-resonant Link in DC side)

  • 유권종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.324-327
    • /
    • 1990
  • In this paper describes the feasibility study on a single-phase / three-phase voltage-fed inverter using 1GBTs, incorporating voltage-mode quasi-resonant DC Link and the instantaneous Sinusoidal Current tracking adaptive control implementation under zero voltage switching resfriction. The simulation and experimental results are shown here and discussed for single-phase voltage-fed and three-phase voltage-fed inverter in order to verify the new operating principle of the Inverter topology proposed here.

  • PDF

제어 자유도를 한 차원 증가시킨 순시무효전력 보상이론 (Instantaneous Reactive Power Compensation Theory Increasing The Control Freedom One Degree Higher)

  • 김효성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2481-2483
    • /
    • 1999
  • This paper proposed the p-q-r coordinate system where the instantaneous active power p, and the two instantaneous reactive powers $q_{q}$, $q_{r}$ were defined. The three power components are linearly independent, so the compensation for the two instantaneous reactive powers leads to control the two components of the current space vector. With the theory, the neutral current of a three-phase four-wire system can be eliminated by only compensating the instantaneous reactive power using no energy storage element.

  • PDF

순시무효전력 보상에 의한 중성선 전류의 제거 (Eliminating the Neutral Current by the Instantaneous Reactive Power Compensation)

  • 김효성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.131-133
    • /
    • 1998
  • This paper, proposed the p-q-r coordinate system where the instantaneous active power p, and the two instantaneous reactive powers $q_{q}$, $q_{r}$ were defined. The three power components are linearly independent, so the compensation for the two instantaneous reactive powers leads to control the two components of the current space vector. With the theory, the neutral current of the three-phase four-wire system can be eliminated by only compensating the instantaneous reactive power using no energy storage element.

  • PDF

순간압력강하치의 통계적 해석을 통한 경사관내 2상유동양식의 판별 (Identification of Two-Phase Flow Patterns in a Inclined Duct Based upon a Statistical Analysis of Instantaneous Pressure Drop)

  • 이상천;이정표;김중엽
    • 대한설비공학회지:설비저널
    • /
    • 제17권5호
    • /
    • pp.590-597
    • /
    • 1988
  • Characteristics of flow regime transitions in inclined upwards gas-liquid two-phase flow have been investigated based upon a statistical analysis of instantaneous pressure drop curves through an orifice. The probability density functions of the curves indicate distinct patterns depending upon two-phase flow regime, which are very similar to those of horizontal two-phase. The dimensionless intensity of fluctuations of the pressure drops sharply change as the flow transitions such as plug-slug, pseudo slug-slug and annular-slug take place. The effects of inclination angle on the flow regime transitions have been also investigated. The results show that the method to identify the flow pattern based upon the statistical analysis of instantaneous pressure drops is suitable for inclined flow as well as horizontal flow.

  • PDF

Lead Angle 제어에 의한 복권형 하이브리드 스테핑 전동기의 상전류 변화에 관한 연구 (Phase Current Variation of Bifilar-Wound Hybrid Stepping Motor by Lead Angle Control)

  • 우광준;이종언
    • 조명전기설비학회논문지
    • /
    • 제12권1호
    • /
    • pp.26-34
    • /
    • 1998
  • 본 연구에서는 복권형 하이브리드 스테핑 전동기의 Lead Angle에 따른 순시 상전류값의 변화를 보이고 이를 실험적으로 확인하였다. Lead Angle에 따른 순시 상전류값의 변화는 상권선이 여기된 시점에서의 회전자 위치에 대한 정보를 제공한다. 따라서 복권형 하이브리드 스테핑 전동기의 폐루프 운전을 위한 회전자 위치검출 방법으로서 전동기의 순시 상전류를 이용할 수 있음을 보였다. 복권형 하이브리드 스테핑 전동기의 모델링을 통해 Lead Angle 함수로 주어지는 순시 상전류 식을 제시하였으며, 컴퓨터 시뮬레이션을 통해 순시 상전류와 회전자 자극위치와의 관계를 도시하고 분석하였고, 상전압 인가후 $\pi/2$ 시점에서의 순시 상전류값을 측정하여 회전자 자극위치 정보를 얻을 수 있음을 실험적으로 확인하였다.

  • PDF

3상 PWM 인버터를 이용한 순간전압보상기의 해석 (Analysis of Instantaneous Voltage Compensator Using 3-Phase PWM Inverter)

  • 최연규;이승요;최규하;목형수;함형원
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.222-227
    • /
    • 1997
  • Unbalanced source voltages due to unbalanced loads in the 3-phase power system is decomposed into positive, negative and zero sequence components. Also, assuming there is no neutural path in the system, the zero sequence component is not shown. Therefore, it is possible to compensate unbalanced source voltage by canceling the negative sequency component of the voltages of the source. In this paper, an algorithm compensating unbalanced source voltages by canceling the negative sequence component is presented and analysis of instantaneous voltage compensator using 3-phase PWM inverter is carried out through computer simulation.

  • PDF