• Title/Summary/Keyword: Instantaneous Frequency

Search Result 337, Processing Time 0.025 seconds

Motor Fault Monitoring using Instantaneous Frequency (순간주파수를 이용한 모터고장진단)

  • Kwak, Ki-Seok;Yoon, Tae-Sung;Park, Jin-Bae;Kho, Jae-Won
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2519-2521
    • /
    • 2005
  • Instantaneous frequency(IF) has important physical meaning for nonstationary signal. Motor current is well known that to be a nonstationary signal whose properties vary with respect to the time-varying normal operating conditions of the motor, particularly with load. Time-frequency methods can overcome the shortcomings of the traditional spectral analysis techniques, nonstationary signal analysis approaches have been introduced. We examine the concept of IF as a potential candidate for condition monitoring of motors.

  • PDF

The Design and Application of IIR Variable Bandwidth Filter (IIR 가변대역폭 필터의 설계 및 응용에 관한 연구)

  • Song, Min;Baek, Seung-Eun;Choe, Jin-Myung;Bien, Zeung-Nam;Lee, He-Young
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.138-141
    • /
    • 2001
  • In this paper, a VBF(variable bandwidth filter) is suggested and analyzed in time-frequency domain. There are four kinds of VBF, which are low-pass VBF, high-pass VBF, band-pass VBF and band-stop VBF. The proposed VBF can extract the components of signals within variable instantaneous bandwidth at a specific time instant. Instantaneous bandwidth is estimated in time-frequency domain. The VBF is represented by rational form in extended Fourier frequency domain.

  • PDF

S-Domain Equivalent System for Electromagnetic Transient Studies PART I : Frequency Dependent Network Equivalent (전자기 과도현상 해석을 위한 S 영역 등가시스템 PART I : 주파수 의존 시스템 등가)

  • 왕용필
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.11
    • /
    • pp.632-638
    • /
    • 2003
  • Modern power systems are very complex and to model them completely is impractical for electromagnetic transient studies. Therefore areas outside the immediate area of interest must be represented by some form of frequency dependent equivalent. The s-domain rational function form of frequency dependent equivalent does not need refitting if the simulation time-step is changed in the electromagnetic transient program. This is because the s-domain rational function coefficients are independent of the simulation time-step, unlike the z-domain rational function coefficients. S-domain rational function fitting techniques for representing frequency dependent equivalents have been developed using Least Squares Fitting(LSF). However it does not suffer the implementation error that exited in this work as it ignored the instantaneous term. This paper Presents the formulation for developing 1 Port Frequency Dependent Network Equivalent(FDNE) with the instantaneous term in S-domain and illustrates its use. This 1 port FDNE have been applied to the CIGRE Benchmark Rectifier test AC system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the 1 port (FDNE) developed with Thevenin and Norton Equivalent network. The study results have indicated the robustness and accuracy of 1 port FDNE for electromagnetic transient studies.

The Instantaneous Phase-Tracking in PLL using the DFT Algorithm (DFT 알고리즘을 이용한 PLL의 순시 추종)

  • Kim, Youn-Seo;Yang, Oh
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.6
    • /
    • pp.141-148
    • /
    • 2008
  • An utility voltage information, including the frequency, phase angle and amplitude is very important in many industrial systems. The grid-connected photovoltaic system in the limelight as alternative energy needs utility voltage information such as frequency, phase angle and magnitude to connect the grid-line. In this paper, it proposes the instantaneous phase-tracking in PLL that uses the frequency from the utility voltage as a sync signal and locks the phase with compensation for phase difference from DPT algorithm. It also proposes not only DFT algorithm execution by every sample not by one period, but also phase-tracking method in a wide range of frequency not a fixed one. This paper shows the feasibility and the usefulness of the proposed methods through the computer simulation and the experiment.

Frequency Characteristics of the Synchronous-Frame Based D-Q Methods for Active Power Filters

  • Wang, Xiaoyu;Liu, Jinjun;Hu, Jinku;Meng, Yuji;Yuan, Chang
    • Journal of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.91-100
    • /
    • 2008
  • The d-q harmonic detecting algorithms are dominant methods to generate current references for active power filters (APF). They are often implemented in the synchronous frame and time domain. This paper researches the frequency characteristics of d-q synchronous transformations, which are closely related to the analysis and design issues of control system. Intuitively, the synchronous transformation is explained with amplitude modulation (AM) in this paper. Then, the synchronous filter is proven to be a time-invariant and linear system, and its transfer function matrix is derived in the stationary frames. These frequency-domain models imply that the synchronous transformation has an equivalent effect of frequency transformation. It is because of this feature, the d-q method achieves band-pass characteristics with the low pass filters in the synchronous frame at run time. To simplify these analytical models, an instantaneous positive-negative sequence frame is proposed as expansion of traditional symmetrical components theory. Furthermore, the synchronous filter is compared with the traditional bind-pass filters based on these frequency-domain analytical models. The d-q harmonic detection methods are also improved to eliminate the inherent coupling effect of synchronous transformation. Typical examples are given to verify previous analysis and comparison. Simulation and experimental results are also provided for verification.

Control and Implementation of Dual-Stator-Winding Induction Generator for Variable Frequency AC-Generating System

  • Bu, Feifei;Hu, Yuwen;Huang, Wenxin;Shi, Kai
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.798-805
    • /
    • 2013
  • This paper presents the control and implementation of the dual-stator-winding induction generator for variable frequency AC (VFAC) generating system. This generator has two sets of stator windings embedded into the stator slots. The power winding produces the VFAC power to feed the loads, and the control winding is connected to the static excitation controller to control the generator for output voltage regulation with speed and load variations. On the basis of the idea of power balance, an instantaneous slip frequency control (ISFC) strategy using the information of both the output voltage and the output power is used in this system. A series of experiments is carried out on a 15 kW prototype for verification. Results show that the system has good static and dynamic performance in a wide speed range, which demonstrates that the ISFC strategy is suitable for this system.

Static Var Compensator Using Current Source PWM Converter (전류형 PWN 콘버어터의 희한 정지형 무효전력 보상장치에 관한연구)

  • 김철우;권순재;김광태
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.11
    • /
    • pp.1183-1190
    • /
    • 1990
  • In this paper, instantaneous reactive power compensation algorithm is proposed and analyzed. The static Var generator developed in this paper is the current source PWM converter using hysteresis comparator method, which compensates the reactive power by detecting each instantaneous phase voltage and line current, independently. Some aspects on the static Var compensator-such as inductance, capacitance, hysteresis width, and switching frequency, etc.-are discussed. The dynamic performances are examined through digital simulation and experimental test.

  • PDF

Active Tonal Noise Canceller with Frequency Tracking

  • Na, Hee-Seung;Park, Young-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.1E
    • /
    • pp.84-88
    • /
    • 1996
  • In this paper, we propose a novel adaptive digital filter for tonal noise cancellation, with a frequency tracking capability. The proposed algorithm not only estimates the magnitude and phase of the tonal disturbance but also tracks its frequency, which changes in quasi-static manner. The algorithm uses the steepest descent method and the instantaneous frequency approach for the phase/magnitude estimation and frequency tracking, respectively. A number of computer simulations have been carried out in order to demonstrate the feasibility of the proposed ANC algorithm under various conditions.

  • PDF

Realization of Variable Bandwidth Filter for Decomposition of Speech Signals into AM-FM Components (음성신호의 AM-FM 성분 분리를 위한 가변대역폭 필터 구현)

  • 이희영;김용태
    • Proceedings of the IEEK Conference
    • /
    • 2003.07e
    • /
    • pp.2208-2211
    • /
    • 2003
  • In this paper, a variable bandwidth filter(VBF) is realized with the purpose of the decomposition of speech signals with time-varying instantaneous of frequencies. The proposed VBF can extract AM-FM components of a speech signal whose time-frequency representations(TFRs) are not overlapped in time-frequency domain

  • PDF

Single-phase Active Power Filter Based on Rotating Reference Frame Method for Harmonics Compensation

  • Kim, Jin-Sun;Kim, Young-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.94-100
    • /
    • 2008
  • This paper presents a new control method of single-phase active power filter (APF) for the compensation of harmonic current components in nonlinear loads. To facilitate the possibility of complex calculation for harmonic current detection of the single phase, a single-phase system that has two phases was constructed by including an imaginary second-phase giving time delay to the load current. The imaginary phase, which lagged the load current T/4 (Here T is the fundamental cycle) is used in the conventional method. But in this proposed method, the new signal as the second phase is delayed by the filter. Because this control method is applied to a single-phase system, an instantaneous calculation was developed by using the rotating reference frames synchronized to source-frequency rather than by applying instantaneous reactive power theory that uses the conventional fixed reference frames. The control scheme of single-phase APF for the current source with R-L loads is applied to a laboratory prototype to verify the proposed control method.