• 제목/요약/키워드: Instantaneous Frequency

검색결과 337건 처리시간 0.033초

공진회로를 이용한 고효율 Buc 컨버터의 구현 (Implementation of the high efficiency buck converter using the resonant circuit)

  • 임승하;사공석진
    • 전자공학회논문지B
    • /
    • 제33B권11호
    • /
    • pp.167-174
    • /
    • 1996
  • For the decreasing of switching loss, this paper designs the improved buck converter circuit and then compare with the conventional buck converter and finally analyzes the performance. When the switch is turn-off, in the buck converter using the smoothing capacitor, the flow of transient current and peak voltage having the high frequency components was generated because of the instantaneous open-state in the teminals of the switch. However, the buck converter presented in this paper eliminated this disadvantage by using the L-C circuit. Therefore, the higher PF in 0.85 is achieved than that of the buck converter using the smoothing capacitor. Also, due to the decreasing of the harmonic contain rate, the current usage rate is to be higher than that of the conventional buck converter by 4.48dB and the output voltage varient rate for the step response is to be lower 1.32 times than that of the conventional buck converter.

  • PDF

음향 가진 하에서 비예혼합 화염거동에 관한 가시화 연구 (A visual investigation of non-premixed flame behavior under acoustic excitation)

  • 이기만;오세기
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.871-877
    • /
    • 2001
  • Experimental study was conducted to investigate the effects of axial forcing on the flame structures near the nozzle exit of non-premixed flame. The most notable observation is that the direction of vortical motions is changed at some ranges, according to the increase of excitation amplitude. Especially, the elongation flame and the phenomenon of In-burning are always occurred when the vortical motion turnabout. In an analysis of the flame/flow visualization by means of direct photography and RMS technique, a plausible explanation can be made that above phenomena are related only to the amplitude of phase average velocity between the instantaneous velocity elements of excited flow.

  • PDF

Online output power measurement of full-bridged MOS-FET RF power inverter operating at shortwave frequency

  • Suzuki, Taiju;Suyama, Tetsuji;Yamamoto, Tetsuya;Ikeda, Hiroaki;Yoshida, Hirofumi;Shinohara, Shigenobu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.1920-1923
    • /
    • 1991
  • An online RF power measurement is needed for the full-bridged MOS-FET RF power inverter because the output current and/or voltage waveform is other than sinusoidal. In order to satisfy the requirement, the online measurement of the output power of this type of RF power inverter by the use of the PC-98 personal computer has been presented. The current and voltage waveforms are sensed by the digital oscilloscope probes so as to obtain the instantaeous power and they are entered into the PC98 personal computer so as to average the instantaneous powers. The RF power of up to 1 kw at 1 MHz measured for the power inverter at the output transformer. This method was confirmed to be applied to evaluate the load resistance change with temperature.

  • PDF

New Analysis on Reception of M-ary FSK Signals over Rician Fading Channels

  • Kim, Chang-Hwan;Han, Young-Yearl
    • 한국전자파학회논문지
    • /
    • 제11권7호
    • /
    • pp.1176-1185
    • /
    • 2000
  • In this paper, we analyze the distribution of the envelope of the received signal over frequency-nonselective slow Rician fading channels with aadditive white Gaussian noise(AWGN). Especially, we can obtain the error rate performance of noncoherent M-ary FSK(MFSK) over slow and flat Rician fading channels and AWGN from the new probability density function(PDF) of the envelope, not PDF of the instantaneous signal-to-noise ratio(SNR) published before, of the received signal. When coherent MFSK signals experience the Rician fading channel, the performances are derived, using the union bound.

  • PDF

유압용 액셜 피스톤 펌프의 유량맥동 계측에 관한 연구 (A Study on the Measurement of Delivery Flow Ripple Generated by Hydraulic Axial Piston Pumps)

  • 이상기
    • 한국생산제조학회지
    • /
    • 제8권2호
    • /
    • pp.35-43
    • /
    • 1999
  • The paper describes an approach for measuring delivery flow ripple generated by oil hydraulic axial piston pumps. In order to reduce pressure ripple which cause to undesirable noise. vibration and fatigue in hydraulic systems it is indispensible measure a delivery flow ripple from pumps. Since the flow ripple measurement of flow pumps is independent of the dynamic characteristics of the connected hydraulic circuit the measurement of flow ripple is most suitable for pump fluid-borne noise rating. The measurement of flow ripple with high frequencies from axial piston pumps is made by applying the remote instantaneous flow rate measurement method which is based on the dynamic characteristics between pressure and flow rate in hydraulic pipeline. The measured flow ripple waveforms are influenced by the configuration of V-shaped triangular relief groove in the valve plate. It can be seen that the appropriate relief groove in valve plate reduces the pressure and flow ripple amplitude and frequency spectrum for high harmonics.

  • PDF

Analysis on Decomposition Models of Univariate Hydrologic Time Series for Multi-Scale Approach

  • Kwon, Hyun-Han;Moon, Young-Il;Shin, Dong-Jun
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2006년도 학술발표회 논문집
    • /
    • pp.1450-1454
    • /
    • 2006
  • Empirical mode decomposition (EMD) is applied to analyze time series characterized with nonlinearity and nonstationarity. This decomposition could be utilized to construct finite and small number intrinsic mode functions (IMF) that describe complicated time series, while admitting the Hilbert transformation properties. EMD has the capability of being adaptive, capture local characteristics, and applicable to nonlinear and nonstationary processes. Unlike discrete wavelet transform (DWT), IMF eliminates spurious harmonics and retains meaningful instantaneous frequencies. Examples based on data representing natural phenomena are given to demonstrate highlight the power of this method in contrast and comparison of other ones. A presentation of the energy-frequency-time distribution of these signals found to be more informative and intuitive when based on Hilbert transformation.

  • PDF

SRM의 토크리플 저감을 위한 개선된 논리적 비선형 토크분배기법 (Advanced Logical Non-Linear Torque Sharing Function for Torque Ripple Reduction of SRM)

  • 김태형;이동희;안진우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.887_888
    • /
    • 2009
  • In this paper, an advanced torque control scheme of Switched Reluctance Motor (SRM) using modified non-linear logical TSF (Torque Sharing Function) based on the DITC (direct instantaneous torque control) with PWM(Pulse Width Modulation). In the proposed control scheme, a simple calculation of PWM duty ratio, switching rules from DITC and non-linear torque sharing function can reduce the torque ripple with fixed switching frequency. The proposed control scheme is verified by the computer simulations and experimental results.

  • PDF

수직벽 전방에서의 흡입/토출을 이용한 후류제어 연구 (Study of Wake Control by Blowing and Suction in Front of the Vertical Fence)

  • 최영호;김형범
    • 대한기계학회논문집B
    • /
    • 제32권1호
    • /
    • pp.47-53
    • /
    • 2008
  • The effect of periodic blowing and suction of upstream flow on the separated shear flow behind the vertical fence was experimentally investigated. The fence was submerged in the turbulent shear flow and DPIV method was used to measure the instantaneous velocity fields around the fence. Periodic blowing and suction flow was precisely generated by the syringe pump. Spanwise nozzle made 2D planar periodic jet flow in front of the fence and the effect of frequency and maximum jet velocity was studied. From the results, the reattachment length can be reduced by 60% of uncontrolled fence case under the control.

동력조향용 압력평형형 베인펌프의 유량맥동 계측 (Measurement of Flow Ripple Generated by Balanced Vane Pumps in Automotive Power Steering Systems)

  • 김도태;김진
    • 한국자동차공학회논문집
    • /
    • 제8권6호
    • /
    • pp.70-78
    • /
    • 2000
  • A balanced vane pump for the use of automotive power steering systems generates a flow ripple which is imposed upon the mean flow rate. The flow ripple interacts with the characteristics of the connected pipes, valves and steering gear in a complex manner to produce a pressure ripple, also known as fluid-borne noise. In order to reduce vibration level and produce quieter and more reliable power steering systems, it is important to measure the flow ripple produced by a pump with high accuracy and fast response. In this paper, the flow ripple generated by a vane pump in automotive power steering systems is measured by the remote instantaneous flow rate measurement method (RIFM) using hydraulic pipeline dynamics. In experiment, flow and pressure ripple wave forms are measured under various operating conditions. Also, the parameters affected upon the flow and pressure ripple are investigated by the frequency analysis.

  • PDF

최소자승법을 이용한 $Y-\triangle$ 누설 인덕턴스 추정 방법 (Leakage Inductance Estimation of $Y-\triangle$ Transformer Using the Least Square Method)

  • 황태근;이병은;장성일;김용균;강용철
    • 전기학회논문지
    • /
    • 제56권4호
    • /
    • pp.645-650
    • /
    • 2007
  • This paper proposes a parameter estimation technique of a power transformer. Based on the combined equation, it estimates separately the primary and secondary leakage inductances using the least square method from the instantaneous voltages and currents in the steady state. The performance of the proposed technique was investigated by varying the cut-off frequency of the filter and the number of samples per cycle. The estimated values are obtained based on the average value for 41 cycle.